• Title/Summary/Keyword: Impulse Wave

Search Result 239, Processing Time 0.024 seconds

Effect of Nozzle Initial and Exit Wall Angles on Supersonic Flow Field in a Thrust Optimized Nozzle (추력이 최적화된 노즐의 초음속 유동에 대한 노즐벽 초기 및 출구각도의 영향)

  • Jeon, Tae Jun;Park, Tae Seon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.1-13
    • /
    • 2021
  • Effects of the nozzle wall angles on the supersonic flow field in a thrust optimized nozzle were numerically investigated. The combustor and operating condition of 30-tonf rocket engine was selected to study the optimum nozzle shape. The nozzle flow of combustion products was realized by the shifting equilibrium calculation for the propellant of kerosene-LOx. The change of nozzle wall angles induced different developing patterns of the internal and secondary shock wave. The optimum nozzle was obtained when the internal shock was in a specific position at the nozzle outlet. The nozzle wall angles of the optimum nozzle were very similar to those of the optimum nozzle which does not consider the shock wave.

Bolt looseness detection and localization using time reversal signal and neural network techniques

  • Duan, Yuanfeng;Sui, Xiaodong;Tang, Zhifeng;Yun, Chungbang
    • Smart Structures and Systems
    • /
    • v.30 no.4
    • /
    • pp.397-410
    • /
    • 2022
  • It is essential to monitor the working conditions of bolt-connected joints, which are widely used in various kinds of steel structures. The looseness of bolts may directly affect the stability and safety of the entire structure. In this study, a guided wave-based method for bolt looseness detection and localization is presented for a joint structure with multiple bolts. SH waves generated and received by a small number (two pairs) of magnetostrictive transducers were used. The bolt looseness index was proposed based on the changes in the reconstructed responses excited by the time reversal signals of the measured unit impulse responses. The damage locations and local damage severities were estimated using the damage indices from several wave propagation paths. The back propagation neural network (BPNN) technique was employed to identify the local damages. Numerical and experimental studies were conducted on a lap joint with eight bolts. The results show that the total damage severity can be successfully detected under the effect of external force and measurement noise. The local damage severity can be estimated reasonably for the experimental data using the BPNN constructed by the training patterns generated from the finite element simulations.

Consideration of Time Lag of Sea Surface Temperature due to Extreme Cold Wave - West Sea, South Sea - (한파에 따른 표층수온의 지연시간 고찰 - 서해, 남해 -)

  • Kim, Ju-Yeon;Park, Myung-Hee;Lee, Joon-Soo;Ahn, Ji-Suk;Han, In-Seong;Kwon, Mi-Ok;Song, Ji-Yeong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.701-707
    • /
    • 2021
  • In this study, we examined the sea surface temperature (SST), air temperature (AT), and their time lag in response to an extreme cold wave in 2018 and a weak cold wave in 2019, cross-correlating these to the northern wind direction frequency. The data used in this study include SST observations of seven ocean buoys Real-time Information System for Aquaculture Environment provided by the National Institute of Fisheries Science and automatic weather station AT near them recorded every hour; null data was interpolated. A finite impulse response filter was used to identify the appropriate data period. In the extreme cold wave in 2018, the seven locations indicated low SST caused by moving cold air through the northern wind direction. A warm cold wave in 2019, the locations showed that the AT data was similar to the normal AT data, but the SST data did not change notably. During the extreme cold wave of 2018, data showed a high correlation coefficient of about 0.7 and a time lag of about 14 hours between AT and SST; during the weak cold wave of 2019, the correlation coefficient was 0.44-0.67 and time lag about 20 hours between AT and SST. This research will contribute to rapid response to such climate phenomena while minimizing aquaculture damage.

Dielectric Characteristics of Gaseous $SF_6$ for Impulse Voltages in Presence of a Metallic Particle in GIS (가스절연개폐장치에 있어서 금속입자 존재시 임펄스전압에 대한 $SF_6$가스의 절연특성)

  • 이복희;이경옥;이창준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • This paper deals with the dielectric characteristics of $SF_6$ gas gap stressed by $\pm$1.2/44[$mutextrm{s}$] non-oscillating impulse and $\pm$0.4[$mutextrm{s}$]/1.14[MHz] oscillating impulse voltages in the presence of a needle-shape metallic particle in gas-insulated switchgear(GIS). Breakdown voltage-time (V-t) and breakdown voltage-gas pressure (V-p) characteristics were investigated and discussed. The experiments were carried out under highly inhomogeneous field geometry with a needle protrusion whose length and radius are 10[mm] and 0.5[mm], respectively. The gas pressure ranges from 0.1 to 0.5[㎫]. As a result, it was found that the electrical breakdown for both the positive and negative polarity develops with steplike pulses in leader mechanism, When subjected to the positive oscillating impulse voltage, the minimum breakdown voltages appeared in all the gas pressure ranges and the V-t curves have a pronounced upturning at short times to breakdown and give a little dependence of the gas pressure. On the other hand, in the case of the negative polarity the dependence of the V-t and V-p characteristics on the wave shape of the applied voltages is known to be appreciable.

  • PDF

P Wave Dispersion as a Predictor of Idiopathic Paroxysmal Atrial Fibrillation (특발성 발작성 심방세동 환자에서 P파 간격분산의 의의)

  • Hong, Gue-Ru;Kim, Woong;Park, Jong-Seon;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.267-276
    • /
    • 2001
  • Background: P wave dispersion(PWD) is defined as the difference between the maximum and minimal P wave duration in any of the 12 leads of the surface ECG. The prolongation of atrial conduction time and the inhomogeneous propagation of sinus impulse are known electrophysiologic features in patients with paroxysmal atrial fibrillation(PAF). The purpose of this study was to determine the role of P wave dispersion for the prediction of PAF and to evaluate the effectiveness of prophylactic antiarrhythmic therapy. Materials and Methods: The study population included 20 patients with a history of idiopathic PAF and 20 age and sex matched healthy control subjects. We measured the maximum P wave duration(P maximum) and P wave dispersion from 12 lead ECG. Results: P maximum and P dispersion in idiopathic PAF were significantly higher than normal control group($97.2{\pm}12$, $48.5{\pm}9$ msec vs, $76.5{\pm}11$, $21{\pm}8$ msec, respectively p<0.001, <0.001). After 12-month follow up period P maximum and P dispersion were significantly reduced than those of initial state($77.2{\pm}13$, $26.4{\pm}9$ msec vs. $97.2{\pm}12$, $48.5{\pm}9$ msec, respectively p<0.001,<0.001). Conclusion: P dispersion and P maximum were significantly different between patients with idiopathic PAF and healthy control group. Those are easily accessible, non-invasive simple electrocadiographic markers that could be used for the prediction and prognostic factors of idiopathic PAF.

  • PDF

Traveling-wave type CPW InGaAsP Photodecector at 1.55$\mu\textrm{m}$ (1.55$\mu\textrm{m}$ 진행파형 CPW InGaAsP Photodetector)

  • Yun, Yeong-Seol;Gang, Tae-Gu;Lee, Jeong-Hun;Ok, Seong-Hae;Gong, Sun-Cheol;Choe, Yeong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.3
    • /
    • pp.41-48
    • /
    • 2002
  • The bandwidth limitation of traveling-wave electroabsorption modulator(TW-EAM) is determined by the transit time, the velocity-mismatch between optical-wave and microwave, the impedance-matching, the dispersion and the microwave loss. In this paper, we introduce an hovel impulse response of TW-EAM considering transit time as well as velocity-mismatch. We analyze the effect of transit-time and velocity-mismatch at the same time, using the FDTD method. We investigate the modulation bandwidth by changing the depth of the intrinsic region. We suggest that the optimum depth of the intrinsic region is 0.2${\mu}{\textrm}{m}$ when the absorption coefficient($\alpha$) is 0.2${\mu}{\textrm}{m}$-1.

Development of Structural Analysis System of Bow Flare Structure(3) - Dynamic Structural Analysis - (선수 구조부 구조해석 시스템 개발(3) - 동적 구조해석 -)

  • S.G. Lee;C.K. Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.1
    • /
    • pp.99-110
    • /
    • 2000
  • The damages due to wave impact loads are largely affected by impact pressure impulse and impact load area. The objective of this study is, as the third step, to perform dynamic structural analysis of bow flare structure of 300,000 DWT VLCC using LS/DYNA3D code, and to verify its dynamic structural behaviors. The impact load areas of stiffener space $1.5s{\times}1.5s$ and $2.5s{\times}2.5s$ are applied to bow flare structure part with relatively flexible stiffeners, and with stiff members such as stringers, webs etc., respectively, under the wave impact load with peak height 6.5MPa, tail 1.0MPa, and duration time 5.0msec. Through the dynamic structural analysis in this study, it might be thought that the structural strength of bow flare structure is generally sufficient for these wave impact load and areas, except that large damages were found at bow flare structure area with flexible wide span stiffeners.

  • PDF

The Susceptibility of Electronic Circuits inside the Cavity by HPEM(High Power Electromagnetics) Environment (금속 함체내부로 입사되는 고출력 전자기 펄스에 대한 전자회로의 민감성 분석)

  • Hwang, Sunl-Mook;Kwon, Hae-Ok;Huh, Chang-Su;Choi, Jin-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1892-1897
    • /
    • 2012
  • Modern electronic circuits are of importance for the function of communication, traffic systems and security systems. An intentional threat to these systems could be of big casualties and economic disasters. This study has examined susceptibility of electronic circuits inside the cavity by HPEM(High Power Electromagnetics). The UWB measurements were done at an anechoic chamber using a RADAN voltage source, which can generate a transient impulse of about 200 kV. The HPEM wave penetrated inside the metal case appeared to the long damped ringwave of pulse length compared with the incident wave. In addition, the resonant frequency generated inside the metal case occurred primarily in the range of 1~3 GHz. The frequency band of 1~3 GHz was influenced on the electronic circuit, which was confirmed by an external antenna and an internal absorber. The electronic circuit was influenced by HPEM infiltrated into the cavity at the 86 kV/m out of the metal cases. Also in case of an absorber the susceptibility of an electronic circuit was smallest among other cases(aperture, antenna). It is considered that absorber has a function absorbing electromagnetic wave infiltrated into the cavity and simultaneously limiting resonance by varying a boundary condition inside the cavity. Based on the results, electronic equipment systems could be applied to protection that has suited system requirements.

Development of Structural Analysis System of Bow Flare Structure(2) - Prediction of Wave Impact Load Area - (선수 구조부 구조해석 시스템 개발(2) - 파랑충격하중 면적의 추정 -)

  • S.G. Lee;J.W. Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.4
    • /
    • pp.87-94
    • /
    • 1999
  • Empirical design is still used to avoid a structural damage because impact phenomenon and structural behaviour due to wave impact load can not examined accurately. The damage due to wave impact load is largely affected by impact pressure impulse and impact load area. The objective of this study is, as the second step, to develop an efficient scantling program of bow flare structure, and to predict its impact load area by comparing maximum dented deformations at center of idealized panel structure model of bow flare structure of 300k DWT VLCC using LS/DYNA3D code, which will be used for its verification of dynamic structural analysis, as the next step. Through this study, the impact load area was estimated as $1.5s{\times}1.5s$ stiffener space(s) in the case of panel with stiffeners and as $2.5s{\times}2.5s$, with stringers, under impact pressure curve with peak height 6.5MPa, tail height 1.0MPa, and duration time 5.0msec.

  • PDF

Analysis of Wave Reflection Characteristics for Bottom Proection Bio Block (해저침식방호용 바이오 블록의 파랑반사특성 분석)

  • Lee, J.W.;Kim, J.S.;Kim, H.J.;Lee, Y.H.;Lee, D.H.
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.270-272
    • /
    • 2013
  • In order to protect coastal facilities mainly from wave and current actions, the self-locking bio blocks constituting component elements of protecting structures against scouring were designed. These blocks are adapted to the sloping bottom, coastal dunes, and submerged coastal base counteracting the destructive and erosive impulse action. A series of laboratory experiments is necessary to investigate the reflection of water waves over and against a train of protruded or submerged shore structures and compare the reflecting capabilities of incident waves including wave forces. In this study the hydraulic model experiment was conducted to identify the performance of newly designed water affinity bio blocks to keep the coast slope and bottom mound from scouring by reduction of the reflection coefficient and to convince stability of the placements. Revised design of each element of blocks were also tested for field conditions. From the result of experiment, the field applicability of the developed blocks and placement is to be discussed afterward.

  • PDF