• 제목/요약/키워드: Impression materials

검색결과 310건 처리시간 0.026초

전악인상채득시 인상재가 경석고 모형의 정확도에 미치는 영향 (THE INFLUENCE OF IMPRESSION MATERIALS ON THE ACCURACY OF THE STONE CASTS POURED FROM COMPLETE ARCH IMPRESSION)

  • 이수영;장익태
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.207-218
    • /
    • 1993
  • The purpose of this study was to evaluate the reproducing accuracy of stone casts made from complete arch impressions using different impression materials. The impression materials studied were 1) polyether, 2) polysulfide, 3) polyvinyl siloxane, and 4) irreversible hydrocolloid. Impressions were made from a partially edentulous acrylic resin model with metal inserts in canine, first molar region bilaterally and mid palatal vault region. Each distance between 2 out of 5 meauring points was measured by using 3dimensional measuring machine. Impressions were poured at once with a type IV dental stone. Data were analyzed using t-test with a sample size of six. The results were as follow : 1. Polysulfide and polyether were significantly superior to polyvinyl siloxane and irreversible hydrocolloid in reproducing full arch model(p<0.05), but there were no statistical differences in amount of dimensional reproducing accuracy for full arch impression between polysulfide and polyether(p>0.05). 2. There were statistical differences in amount of dimensional reproducing accuracy between edentulous area and tooth bound area for polysulfide and polyether(p<0.05). but no statistical differences were observed for polyvinyl siloxane and irreversible hydrocolloid(p>0.05).

  • PDF

Holographic Interferometry를 이용한 탄성 고무 인상재의 체적변화에 관한 연구 (DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS USING HOLOGRAPHIC INTERFEROMETRY)

  • 하치양;이성복;우이형
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.574-592
    • /
    • 1996
  • This study investigated the time-dependent dimensional changes of elastomeric impression materials using holographic interferometry. Six commercial impression materials, Permlastic(polysulfide), Xantopren VL (condensation silicone), low and medium viscosity of Exafine, Provil (addition silicone), and Impregum(polyether), were selected. Steel plate was used as custom tray, and each impression specimen was 20 mm in width, 15 mm in length and 3 mm in thickness. Each impression material was evaluated at 30 minutes, 1, 2, 4, 6, 8 and 12 hours after setting using real-time holography. The results were as follow : 1. Xantopren VL and Permlastic showed relatively severe and continuous dimensional changes after setting. Low viscosity of Exafine, Provil, Impregum showed relatively slight dimensional changes with function of time and medium viscosity of Exafine showed almost no dimensional change from 2 hours after setting to 6 hours. 2. On initial dimensional changes within 1 hour, the amount of change in low viscosity of Exafine was the least and Xantopren VL was the largest. 3. On dimensional changes at 4 hours after setting, the amount of change in medium viscosity of Exafine was the least and tile change of Xantopren VL was the largest. 4. In overall dimensional stability during 12 hours, medium viscosity of Exafine was the most stable and Xantopren VL and Permlastic were least stable.

  • PDF

임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교 (Comparative accuracy of implant impression techniques with different splinting materials)

  • 홍기윤;신수연
    • 구강회복응용과학지
    • /
    • 제39권1호
    • /
    • pp.9-20
    • /
    • 2023
  • 목적: 하악 부분 무치악 모형에서 pick-up type 인상용 코핑을 사용한 개방형 인상 채득법과 transfer type 인상용 코핑을 사용한 폐쇄형 인상 채득법, 개방형 인상 채득법에서 pick-up type 인상용 코핑 고정 재료에 따른 인상 채득 정확성을 비교 하고자 하였다. 연구 재료 및 방법: 하악 부분 무치악 모형의 좌측 구치부에 직경 4.5 mm, 길이 11.5 mm의 임플란트 고정체 두 개 식립 후 3D 프린터를 이용하여 개방형 개인 트레이 30개 폐쇄형 개인 트레이 10개를 제작하였다. 제작한 개인 트레이를 이용하여 PN군: 개방형 인상 채득법(non-splint), PG군: 개방형 인상 채득법(splint GC pattern resin), PH군: 개방형 인상 채득법(splint Herifix), TN군: 폐쇄형 인상 채득법으로 나누어 각 군당 10회씩 총 40회의 인상 채득을 진행하였다. 인상채득 후 석고 모형을 제작하여 모델 스캐너로 스캔 후 역설계 프로그램으로 스캔오차를 측정하여 95% 유의수준으로 평가 하였다. 결과: 폐쇄형 인상 채득법 TN군이 개방형 인상 채득법 PN군 보다 더 낮은 오차값을 보였다. 개방형 인상 채득법(splint)에 사용된 인상용 코핑 고정 재료 간의 비교 결과에서는 PH군에서 가장 낮은 오차값을 보였으며 PN군, PG군 순으로 정확한 인상 채득 정확성을 보여주었다. 결론: 임플란트 인상 채득 방법이나 인상용 코핑의 연결 고정 유무에 따른 각 군 간의 정확성에 유의한 차이는 없다.

치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향 (Effect of interproximal undercut on the dimensional accuracy of impression)

  • 이주리;김석규
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.330-336
    • /
    • 2015
  • 목적: 본 연구의 목적은 치간 유두의 소실로 인해 치아 사이에 언더컷이 존재하는 경우 이것이 인상체의 정확도에 영향을 미치는지 알아보고자 하는 것이다. 재료 및 방법: 2종류의 부가중합형 실리콘 인상재($Extrude^{(R)}$ Wash, $Imprint^{TM}$ II Quick Step Light Body)와 한 종류의 알지네이트 인상재(Cavex Impressional)로 상악 주모형의 인상을 채득하여 얻은 실험모형상의 두 점 사이의 거리를 측정하여 주모형과 비교하여 모형의 변형 정도를 측정하였다. 세 종류의 인상재에서 얻은 실험 모형들을 치간 유두가 존재하는 군과 존재하지 않는 군으로 나눠 총 6개의 군을 평가하였으며, 각 군당 6개의 모형을 측정하였다. 삼차원 광학 스캐너로 실험모형을 스캔한 후, 하나의 모형당 6개의 두 점 사이의 거리를 삼차원 디지털 계측 소프트웨어 상에서 측정하였다. 측정 거리의 변화 정도를 백분율로 계산하여 모형의 변형률을 구하였으며, 이것을 이원분산분석을 이용하여 유의수준 .05에서 분석하였다. 결과: 측정거리 6개 중 3개에서 인상재에 따라 통계적으로 유의한 차이를 보였다. 반면, 치간 유두의 존재 여부에 따른 차이는 알지네이트 인상재에서 하나의 측정 거리에서만 유의한 차이를 보였을 뿐(P=.047), 다른 측정거리들과 인상재에서는 통계적으로 유의성 있는 차이를 나타내지 않았다. 결론: 치간 유두의 소실로 인한 언더컷의 존재가 부가중합형 실리콘 인상재와 알지네이트 인상재의 체적 정확도에 미치는 영향은 크지 않았다.

Application study of silicon impression material for reducing metal artifacts: preliminary study for head and neck cancer radiotherapy

  • So Hyun Park;Jinhyun Choi;Byungdo Park;Jeongho Kim;Heesoo Lim;Dae-Hyun Kim
    • Journal of Medicine and Life Science
    • /
    • 제20권2호
    • /
    • pp.83-88
    • /
    • 2023
  • Metal artifacts cause inaccuracies in target delineation, radiation treatment planning, and delivery when computed tomography images of a radiotherapy patient implanted with a high-density material in the body are acquired. In this study, we investigated the possibility of obtaining improved images in clinical trials through metal artifact reduction using silicon impression materials without the need for a specific metal artifact reduction algorithm. A silicon impression material exhibiting a constant Hounsfield unit (HU) value according to the mixing ratio of the catalysts and bases was selected. The material did not exhibit any change in weight or shape over time. For both the instances of inserting the metal material and applying the silicon impression material, the HU value and dose were compared with homogeneous cases filled with water-equivalent materials. When the silicon impression material was applied to the region where the high-density material was located, the HU value was within 5% and the dose was within 3% compared with those of the homogeneous cases. In this study, the silicon impression materials reduced metal artifacts. However, because the composition, shape, size, and location of high-density materials differ, further studies are required to consider these factors in clinical applications.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials

  • Nassar, Usama;Flores-Mir, Carlos;Heo, Giseon;Torrealba, Ysidora
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.182-187
    • /
    • 2017
  • PURPOSE. Vinyl polyether silicone (VPES) has a different composition from other elastomeric impression materials as it combines vinyl polysiloxane (VPS) and polyether (PE). Therefore, it is important to study its properties and behavior under different test conditions. This study investigated the dimensional stability of 5 VPES consistencies when stored for up to 2 weeks, with and without using a standard disinfection procedure. MATERIALS AND METHODS. 40 discs of each VPES consistency (total 200) were made using a stainless steel die and ring as described by ANSI /ADA specification No. 19. 20 discs of each material were immersed in a 2.5% buffered glutaraldehyde solution for 30 minutes. Dimensional stability measurements were calculated immediately after fabrication and repeated on the same discs after 7 and 14 days of storage. The data was analyzed using two-way ANOVA with a significance level set at ${\alpha}=0.05$. RESULTS. The discs mean contraction was below 0.5% at all test times ranging from $0.200{\pm}0.014$ to $0.325{\pm}0.007$. Repeated measures ANOVA showed a statistically significant difference after 2-week storage between the disinfected and non-disinfected groups (P < .001). Although there was no statistically significant difference between the materials at the time of fabrication, the contraction of the materials increased with storage for 1 and 2 weeks. CONCLUSION. The dimensional changes of VPES impression discs after disinfection and prolonged storage complied with ANSI/ADA standard. The tested VPES impression materials were dimensionally stable for clinical use after disinfection for 30 minutes in glutaraldehyde and storage for up to 2 weeks.

계면활성제와 소포제가 실리콘 고무인상재의 물성에 미치는 영향 (Effect of Surfactant and Anti-foaming Agent on the Properties of Silicone Rubber Impression Material)

  • 김경남;조리라;오영일;강승경;정경호
    • Elastomers and Composites
    • /
    • 제36권2호
    • /
    • pp.102-110
    • /
    • 2001
  • Nonylphenoxy poly(ethylene) ethanol homologues, caster oil poly(ethylene) ethanol homo-logues 및 sodium perfluoroalkyl carboxylates의 세 가지 종류 계면활성제를 사용하여 고무인상재의 젖음성 향상 연구를 수행한 결과 불소 관능기가 도입된 sodium perfluoroalkyl carboxylates 계면활성제의 경우 다른 계면활성제를 사용한 경우에 비해 고무인상재의 초기 표면에너지 값은 유사했으나 평형상태에 이른 후의 표면에너지 값이 낮아 치아와의 젖음성이 가장 우수한 것으로 나타났다. 또한, 수소가스의 발생을 억제시키고 미세부 재현성을 높이기 위해 소포제를 사용한 결과 젖음성이 향상된 sodium perfluoroalkyl carboxylates를 포함한 조성에 소포제를 첨가할 경우 인열물성이 약 40% 이상 증가하였는데, 이는 소포제가 고무인상재 내부의 반응으로 생성되는 수소가스의 발생을 억제하기 때문이다. 따라서, 소포제는 고무인상재의 표면특성에는 크게 영향을 미치지 않으면서 인상재 내부에 발생되는 기포를 효과적으로 억제 혹은 제거하여 고무 인상재의 기계적물성을 향상시킴을 알 수 있었다.

  • PDF

Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 2017
  • PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with ${\alpha}$-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

알지네이트 인상재의 혼합방법과 트레이 어드헤시브 도포에 따른 모형의 정확도 비교 (COMPARISON OF THE ACCURACY OF STONE CASTS MADE FROM ALGINATE IMPRESSION MATERIAL BY MIXING METHODS AND APPLICATION OF TRAY ADHESIVE)

  • 김진형;정문규
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.492-501
    • /
    • 2001
  • The use of alginate impression materials today is prevalent because of its efficiency and simplicity in clinical settings. Unfortunately, the simplicity of the procedure tends to lull the dentist into a sense of well-being, and lead him into using careless or sloppy technique. Alginate impression materials are used to fabricate diagnostic and preliminary casts, and the final cast. Incorrect use of this material is known to affect the accuracy of the final prosthesis. The purpose of this study was to compare the effect of different mixing methods of alginate impression material and tray adhesive on the accuracy of the stone cast produced by each method. A total of 30 stone casts were produced by using 3 different types of mixing methods (10 stone cast for each mixing method, respectively). The first method utilized an automatic-mixing machine to mix alginate while the second method was carried out manually, strictly following manufacturer's instructions. The third method also involved manual mixing, but did not follow the manufacturer's instructions and was done in a random fashion. Also, 20 additional stone casts were produced by using alginate with or without tray adhesives were included in the study to evaluate effects of tray adhesives on the accuracy of alginate impression. 10 stone casts were produced by adding tray adhesives to the interior surface of the impression tray prior to taking the impression. The other 10 excluded this step. A total of 50 stone casts were analyzed by the three-dimensional measuring machine to measure and compare the dimensional changes of the impression material of each group. The results are as follows. 1. No significant difference was found between the automatic mixing group and the manually-mixing group(p>0.05). 2. For the group that followed manufacturer's instructions, less dimensional changes were record ed than the group that didn't in measuring distanced 4(p<0.05). 3. The group that used tray adhesives showed less dimensional changes(p<0.05). The findings revealed that mechanical methods of mixing alginate impression materials had little influence on dimensional changes. However, it is proven that following manufacturers instructions in alginate impression taking is an important step in acquiring accurate impressions and tray adhesives may play an important role in enhancing the results.

  • PDF