• 제목/요약/키워드: Impression Technique

검색결과 178건 처리시간 0.034초

Implant overdenture impressions using a dynamic impression concept

  • Lee, Byung-Kil;Park, Sang-Hun;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.66-70
    • /
    • 2014
  • A dynamic impression is a functional impression that records the functional movement of the patient's own muscle and muscle attachment. This process reduces the number of random factors. This article describes a method for making a special tray using a dynamic impression concept that was made from provisional dentures used for implant healing. The individual tray is used to make a wash-impression to record the features of the mucosa in detail. The main advantage of this technique is that it provides a functional relationship of the implant components to the supporting tissues without overextension because provisional denture had been used for 2 months and the border length of individual tray was nearly the same as that of provisional denture. The delivery of the prosthesis constructed using this impression technique is time-saving because there is no need for border molding and there are fewer post-insertion appliance adjustments.

심한 치조제 흡수를 보이는 무치악 환자에서 임시 의치를 사용한 기능 인상에 의한 총의치 수복 증례 (Functional impression technique using temporary denture for rehabilitation of severely atrophic maxillary and mandibular ridges)

  • 서영교;배정윤;김현희
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.238-244
    • /
    • 2019
  • 연성 이장재는 점탄성적 특수성으로 인하여 인상 채득 후 바로 치과용 경석고를 주입할 시, 기능 인상에 사용할 수 있다. 본 증례는 78세의 남성으로 새로운 의치를 제작하고 싶다는 주소로 내원하였다. 하악 치조제의 심한 흡수로 인하여, 폐구법을 통한 기능 인상을 채득하기로 계획하였다. 먼저, 상, 하악 임시 의치의 제작을 시행하고, 연성 이장재를 내면에 도포하여 압박된 상, 하악 무치악 치조제의 치유를 유도하였다. 이후, 회복된 상, 하악 치조제에 맞게 내면이 변형된 상, 하악 임시 의치를 이용하여 폐구법을 통한 기능 인상을 채득하였으며, 상악 임시 의치의 치아 배열을 참고하여 최종 의치를 제작하였다. 이상과 같이 완전 무치악 환자에서 임시 의치를 이용하여 기능 인상을 채득하여 만족스러운 유지와 기능을 회복할 수 있었기에 본 증례를 보고하고자 한다.

하악 과두 골절과 심한 잔존치조제 흡수를 보이는 완전 무치악 환자에서 폐구 인상법과 고딕아치 묘기법을 이용한 총의치 수복 증례 (Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption and condyle fracture using gothic arch tracing and closed mouth impression technique: A case report)

  • 최인호;김성아;김나홍;이용상
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.145-152
    • /
    • 2020
  • 심미와 기능이 조화를 이루는 총의치 제작을 위해서는 상하악 관계를 정확히 기록하는 것이 필수적이다. 고딕아치 묘기법은 하악의 운동을 시각적으로 보여주며, 정확하고 반복재현성 있는 중심위를 확립하는데 유용하다. 또한, 고도의 치조제 흡수를 갖는 환자에서는 총의치의 적절한 유지 및 안정을 얻기가 어려운데, 이런 경우 환자의 생리적인 동작으로 변연을 형성하여 의치상연 주위가 가동점막으로 봉쇄되도록 하는 폐구 인상법이 유용할 수 있다. 본 증례에서는 우측 하악과두골절 병력과 고도의 하악 치조제 흡수를 보이는 환자에서 폐구인상법과 고딕아치 묘기법을 이용한 총의치로 수복하였고 만족할 만한 결과를 얻어 보고하는 바이다.

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

새로운 인상용 코핑을 이용한 임플란트 인상법의 정확성에 대한 3차원적 비교 연구 (Three Dimensional Comparative Study On The Accuracy Of Impression Technique Using New Impression Coping)

  • 김세라;김인수;박성재;이병옥;고석민
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.323-337
    • /
    • 2010
  • 본 연구는 임플란트 상부 구조물 제작을 위한 pick-up 인상 채득시 flag type의 새로운 인상용 코핑을 이용하여 제작된 모형과 기존에 사용되고 있는 인상용 코핑에 의해 제작된 모형의 정확성을 3차원적으로 비교하여 새로운 형태의 인상용 코핑을 사용한 인상법의 유용성을 알아보고자 하였다. 아크릴릭 레진 블록으로 좌측은 전부 무치악, 우측은 제 2 소구치가 상실된 상악 기준 모형을 제작하였다. 상악 우측 제 2소구치, 좌측 중절치, 좌측 견치, 좌측 제 2 소구치, 좌측 제 2 대구치 부위에 외부 육각 연결 방식의 임플란트 고정체를 식립하였다. 기준 모형에 사용된 인상용 코핑 및 코핑 간에 연결 여부에 따라 세 가지 실험군으로 분류하였다; 임플란트 고정체에 flag type 의 인상용 코핑을 체결한 경우 (실험군 I), 기존 형태인 원통형의 인상용 코핑을 체결한 후 인상용 코핑을 자가 중합 아크릴릭 레진으로 연결한 경우 (실험군 Ii), 원통형 인상용 코핑을 체결한 후 자가 중합 레진으로 연결하지 않은 경우 (실험군 III). 총 15개의 모형을 제작하여 인상 채득하여 작업 모형을 제작한 후 기준 모형 및 작업 모형을 5번씩 측정하여 통계 처리하였다. flag type의 인상용 코핑을 이용하여 인상 채득한 군, 기존의 인상용 코핑을 자가 중합 레진으로 splinting하여 인상 채득한 군, 기존의 인상용 코핑을 splinting 하지 않고 인상 채득한 군의 작업 모형에서 각 임플란트 유사체 간 거리 차이는 통계적으로 유의하지 않았다(P >.05). 또한 동일 수평면에 대한 수직적 거리를 비교한 결과 flag type의 인상용 코핑을 사용하여 제작한 작업 모형이 Point 2에서는 기준 모형에 가장 근접한 수치를 보였고 Point 3에서는 오차가 가장 컸으며 이는 통계적으로 유의하였다(P <.05). 그 외 Point에서는 세 가지 방법 간에 통계적으로 유의한 차이는 없었다(P >.05). 새로운 인상용 코핑을 사용한 인상법은 기존의 인상용 코핑을 사용한 인상법과 비교적 유사한 정확성을 보여주었다.

수종의 치과용 탄성인재의 정확도에 관한 연구 (A STUDY ON THE ACCURACY OF SEVERAL DENTAL ELASTOMERIC IMPRESSION MATERIALS)

  • 최명수;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제34권4호
    • /
    • pp.850-868
    • /
    • 1996
  • The accuracy and dimensional stability of impression materials are one of the most important factors for successful prosthodontic treatment. The purpose of this study was to evaluate the accuracy of several dental elastomeric impression materials used widely and clinically : Impregum-$F^{(R)},\;Permlastic^{(R)},\;Silascon^{(R)},\;Perfect^{(R)},\;Xantopren^{(R)}$. There have been many studies to evaluate the accuracy of impression materials. But it has not been decided yet, which method was most suitable for the evaluation of the accuracy. In this study, two resin teeth, #15 & 25, were prepared with rounded shoulder margin and 90 degree cavosurface angle. For the polysulfide rubber and polyether, the custom tray was made at least 24 hours prior to impression taking. For the silicone rubber materials, putty/wash impression technique was applied in taking impressions. Marginal openings of the castings on the master dies and prepared resin teeth were measured under stereomicroscope. The results were statistically analyzed and compared between tested impression materials. The results were as follows ; 1. In the overall accuracy of impression materials, polyether was the most accurate one, followed by polysulfide, additional silicone and condensation silicone. 2. On the first model pouring, condensation silicone had the largest discrepancies and there was significant difference compared to the other impression materials. 3. Polysulfide had the least discrepancies in the first model pouring, but showed larger discrepancies in the immediate second pouring than the first pouring. 4. On the immediate second pouring, the discrepancy of polyether was shown to be the smallest, while the largest one was additional silicone. 5. Polyether and polysulfide rubber using custom impression trays showed superior accuracy to silicone rubber, putty/wash impression technique.

  • PDF

Accuracy of a proposed implant impression technique using abutments and metal framework

  • Lee, Hyeok-Jae;Lim, Young-Jun;Kim, Chang-Whe;Choi, Jung-Han;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권1호
    • /
    • pp.25-31
    • /
    • 2010
  • PURPOSE. This study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cement-on crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated. MATERIAL AND METHODS. Three definitive casts, each with 3 linearly positioned implant analogs at relative angulations 0, 30, and 40 degrees, were fabricated with passively fitted corresponding reference frameworks. Ten impressions were made and poured, using each of the 3 techniques on each of the 3 definitive casts. To record the vertical gap between reference frameworks and analogs in duplicate casts, a light microscope with image processing was used. Data were analyzed by two-way analysis of variance and the Tukey test. RESULTS. The open tray techniques showed significantly smaller vertical gaps compare to closed tray technique (P < .05). The closed tray and the resin-splinted open tray technique showed significantly different vertical gaps according to the angulation of implant (P < .05), but the A-F impression technique did not (P > .05). CONCLUSION. The accuracy of the A-F impression technique was superior to that of conventional techniques, and was not affected by the angulation of the implants.

COMPARATIVE ACCURACY OF THE SPLINTED AND UNSPLINTED IMPRESSION METHODS FOR INTERNAL CONNECTION

  • Choi, Jung-Han;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jin
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.352-362
    • /
    • 2005
  • Statement of problem. Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems. Purpose. The purpose of this study was to compare the accuracy of two fixture-level impression techniques in two conditions (parallel and divergent) and to assess the effect of tightening sequences and forces on stresses generated on superstructures in internal connection implant system (Astra Tech). Material and methods. Two metal master frameworks made from two abutments (Cast-to Abutment ST) each and a corresponding, passively fitting, dental stone master cast with four fixture replicas (Fixture Replica ST) were fabricated. Ten dental stone casts for each impression techniques (direct unsplinted & splinted technique) were made with vinyl polysiloxane impressions from the master cast. Strain gauges for each framework were fixed midway between abutments to measure the degree of framework deformation on each stone cast. Pairs of strain gauges placed opposite each other constituted one channel (half Wheatstone bridge) to read deformation in four directions (superior, inferior, anterior, and posterior). Deformation data were analyzed using one-way ANOVA and the Tukey test at the .01 level of significance. And the effect of tightening sequences (right-to-left and left-to-right) and forces (10 Ncm and 20 Ncm) were assessed with ten stone casts made from parallel condition by the splinted technique. Deformation data were analyzed using paired t-test at the .01 level of significance. Conclusions. Within the limitations of this study, the following conclusions could be drawn. 1. Frameworks bent toward the inferior side on all casts made by both direct unsplinted and splinted impression techniques in both parallel and divergent conditions. 2. There was no statistically significant difference of accuracy between the direct unsplinted and splinted impression techniques in both parallel and divergent conditions (P>.01). 3. There was no statistically significant difference of stress according to screw tightening sequences in casts made by the splinted impression technique in parallel condition (P>.01). 4. Greater tightening force resulted in greater stress in casts made by the splinted impression technique in parallel condition (P<.01).

Strain gauge를 사용한 임플랜트 인상법의 정확도 비교 (A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE)

  • 한인택;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

Open and Closed Mouth Impression Techniques for Mandibular Implant Overdenture: Two Cases Report

  • Ha-Jin, Yoon;Jung-Yoon, Bae
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.152-161
    • /
    • 2022
  • Mandibular implant overdenture is a good treatment option for complete edentulous patients with restoring removable prosthesis. Mandibular implant overdenture with two implants and locator attachments is widely used. It is tissue-supported overdenture that is made with the concept of conventional complete denture fabrication. There are two patients who provided impressions by open mouth technique and closed mouth technique in each case. In both cases, mandibular implant overdentures were restored with functionally and aesthetically satisfying results.