A STUDY ON THE TENSILE BOND STRENGTH BETWEEN VARIOUS RESIN TRAY MATERIALS AND RUBBER IMPRESSION MATERIALS (수종의 트레이 레진과 고무 인상재간의 인장 접착강도에 관한 연구)

  • Song Kyung-Won;Lim Ju-Hwan;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.351-365
    • /
    • 2001
  • For accurate impression taking, accurate impression material, solid individual tray, and bond strength between impression materials and resin tray are important factors. The purpose of this study was to evaluate tensile bond strength of rubber impression materials to various tray resin materials. This study tested the time dependent tensile bond strength between commercial brands or poly ether, polysulfide, additional silicone impression materials and commercial brands of self curing tray resin. light activited tray resin when applying adhesive Resin specimens were made with 20mm in diameter, 2mm in thickness. 1 made total 360 specimens, 10 per each group and the tensile bond strength was measured by using the Instron($M100EC^{(R)}$, Mecmesin Co., England). The results were as follows ; Comparisons of various impression materials. 1. In case of Impregum $F^{(R)}$, the bond strength of tray resin was decreased in order of SR $Ivolen^{(R)}$, Ostron $100^{(R)}$ Instant tray $mix^{(R)}$, $Lightplast^{(R)}$. All groups excluding Ostron $100^{(R)}$, Instant tray $mix^{(R)}$ are significant difference (p<0.05). Drying time after applying adhesive, the tensile bond strength of tray resin was insignificantly decreased in order of 10 min drying time group. 1 min drying time group. 5 min drying time group. 2. In case of Permlastic $regular^{(R)}$ the bond strength of tray resin was insignificantly decreased in order of Ostron $100^{(R)}$. SR $Ivolen^{(R)}$, Instant tray $mix^{(R)}$ $Lightplast^{(R)}$. About drying time after applying adhesive, the tensile bond strength of tray resin was significantly decreased in order of 5 min drying time group, 10 min drying time group, 1 min drying time group(p<0.05). 3. In case of Exaflex $regular^{(R)}$. the bond strength of tray resin was decreased in order of $Lightplast^{(R)}$, SR $Ivolen^{(R)}$, Instant tray $mix^{(R)}$, Ostron $100^{(R)}$. $Lightplast^{(R)}$ was significant difference(p<0.05). About drying time after applying adhesive, the tensile bond strength of tray resin was decreased in order of 5 min drying time group, 10 min drying time group, 1 min drying time group(p<0.05). Especially 5 min ding time group was significant difference(p<0.05). According to the results of this study, we can see the greatest tensile bond strength when using Impregrm $F^{(R)}$ and Permlastic $regular^{(R)}$ with self curing tray resin, when using Exaflex $regular^{(R)}$ with light activated tray resin In my opinion, adhesive should be dried more than 5 min before impression taking to achieve the greatest tensile bond strength.

  • PDF

Effect of interproximal undercut on the dimensional accuracy of impression (치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향)

  • Lee, Ju-Ri;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.330-336
    • /
    • 2015
  • Purpose: This study evaluated the effect of loss of interproximal papilla, creating an undercut, on the accuracy of impression materials. Materials and methods: Two addition type silicone impression materials ($Extrude^{(R)}$ Speed Wash, $Imprint^{TM}$ II Quick Step Light Body) and one alginate impression material (Cavex Impressional) were used to make impressions of a maxillary master model simulating clinical conditions with or without interproximal papilla. Stone was poured in the impressions and working casts were fabricated. A total of 6 groups with 6 working casts in each group were scanned using 3-dimensional optical scanner. The accuracy of the impressions was assessed by measuring the dimensional changes (${\Delta}I$ (%)) of 6 distances on working casts compared to a master model with a 3-dimensional digitizing and inspection software. The data were analyzed by two-way ANOVA (P<.05). Results: Three of 6 distances showed statistically significant differences among the impression materials. Only 1 of 6 distances in alginate impression showed a statistically significant difference between casts with and without interproximal papilla (P=.047). Conclusion: The presence of undercut due to loss of interproximal papilla did not significantly influence the dimensional accuracy of addition type silicone and alginate impression materials.

A Study on the Improvement of the Descriptive Form of the Edition and Impression in the Korean Cataloguing Rule (한국목록규칙에서 판과 쇄의 서지요소 기술형식 개선안 연구)

  • Lee, Myounggyu
    • Journal of Korean Library and Information Science Society
    • /
    • v.52 no.3
    • /
    • pp.217-238
    • /
    • 2021
  • The purpose of this study is to identify the problems of describing bibliographic elements such as edition, impression, and year of publication in the current Cataloging Rules, and to present improvements to the KCR and the KORMARC Format. According to changes in the information technology environment in the library, the level and scope of the cataloging that can be provided to users should be adjusted. As data is diversified and descriptive method of metadata develops, the development of bibliographic elements and the change of the descriptive method are changing the framework of the existing standardization. As a research method, we will examine the concept of edition and impression, examine the transition process of description of edition and impression targeting KCR. And we would like to present the methods of bibliographic description to be added or modified through cataloging examples, and examine the format reflected in KORMARC. This study is intended to be limited to the descriptive form of books. The bibliographic elements of the entry in the library must be fully consistent with the bibliographic elements of the material to be catalogued. This study suggests an improvement to the cataloging rules. First, the edition of the cataloging rules shall describe the edition statement and the impression statement. In addition, the description of the year of publication describes the latest year, not the first year of publication of the edition of the material to be catalogued. The descriptive scope of the year of publication is extended to the month of publication. Second, in the KORMARC format, the description of impression in edition statement is given to the identifier in the 250 field, and is numerically described as the second impression. When presenting the month and year of publication, one identifier in the field 260 describes the year of publication and the other identifier describes the month of publication. The description for the month and year of publication is stated the latest month and year on the title page and the colophon of the publication.

Development of Impression Management Education Program for Career Women (직장 여성을 위한 인상관리 교육프로그램 설계)

  • Hwang, Jung-Sun;Lee, Yoon-Jung
    • Journal of Korean Home Economics Education Association
    • /
    • v.34 no.1
    • /
    • pp.97-111
    • /
    • 2022
  • The purpose of this study is to systematically develop an impression management education program for career women by applying the Educational System Development Model [ESD] (Kwon, 1997) based on the research results of Hwang and Lee(2019) on social attractiveness. Since the previous impression management education programs were generally developed by content experts, few of them were developed systematically by considering the learner characteristics, clearly setting the educational goals, and structuring the contents accordingly. In this study, 'social attractiveness' defined by Hwang and Lee (2019) was considered as the educational goal of the impression management education program. In particular, this study focused on the design stage of the ESD model, set teaching goals based on the components of social attractiveness derived from previous studies, and conducted an analysis of teaching activities, the establishment of the educational goals at the specific function level, allocation of time, and establishment of an evaluation plan. The research process was intended to improve the learners' social image directly related to success through a systematic educational program designed to enhance the social attractiveness of working women with various hands-on activities and information. The impression management education program designed in this study has the educational advantage of a learner-centered education program configured to meet the needs and goals of career women. In addition, based on the ESD model, the sub-factors necessary for impression management were identified, and the curriculum was configured to reflect them through mutual communication between the instructor and learners. Therefore, this education program meets the basic requirements of impression management education necessary for career women and is expected to contribute to enhancing the social attractiveness of working women.

A study of Conjunctival Cellular Changes in Dry Eye Patients by Impression Cytology (Impression cytology를 이용한 건성안의 결막 세포변화에 관한 연구)

  • Kim, Jai-Min;Kho, Eun-Gyung;Chae, Soo-Chul;Kim, Soon-Ae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.333-343
    • /
    • 2004
  • Impression cytology refers to application of cellulose acetate filter material to the ocular surface to remove the superficial layers of the conjunctival epithelium. The technique is non-invasive, is easy to perform, causes minimal discomfort to the patient, and can be used to follow changes in the conjunctival ocular surface over time. With this method, the morphology of the conjunctival ocular surface can be studied and the degree of squmaous metaplasia assessed. This study was performed to evaluate the conjunctival surface by impression cytology in dry eye patients. A total of 70 students with no contact lens wearing history were recruited. Subjects were required to fill in a McMonnies dry eye symptom questionnaire. The non-invasive tear thinning time(TIT) test of each subject was measured, followed by Schirmer tear test(STI), tear film break-up time(TBUT) tests and Rose-bengal staining were performed as a baseline. Conjunctival epithelial cells from the inferior bulbar conjunctiva were harvested by the impression cytology technique. The specimens collected were labelled and stained with PAS(Periodic Acid Schift)-haematoxylin. The goblet cells and conjunctival epithelial cells were observed under a light microscope of 400x magnification. The specimens were classified according to the Nelson Grading scale which was based on the degree of squamous metaplasia such as changes of goblet cells density, size/form, N:C(nucleus : cytoplasm) ratio. Dry eye patients were observed morphological changes of the epithelial cells, different nuclear alterations, decrease of the goblet cells density. The degree of cytological changes was related to severity of dry eye conditions. When the epithelial cell morphology was graded according to the system described by Nelson, specimens from the control group revealed 91.43% of the eyes to be grade 0 and 8.57% to be grade 1, whereas of the dry eye patients, 20% were grade 0, 42.86% grade 1, 34.29% grade 2 and 2,86% grade 3. Impression cytology represents a non- or minimally invasive biopsy of the ocular surface epithelium with no side effects or contraindications. It has demonstrated to be a useful diagnostic aid for a wide variety of processes involving the ocular surface. This technique is a safe, simple method and may help increase understanding of various ocular surface alterations in dry eye patients.

  • PDF

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

Maxillary anterior all ceramic restoration using digital impression and CAD/CAM (디지털 인상채득 및 CAD/CAM을 이용한 상악 전치부 보철물 제작과 기존 방식 보철물과의 임상적 비교)

  • Pyo, Se-Wook;Park, Young-Bum;Kim, Jee-Hwan;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.263-269
    • /
    • 2011
  • The digital impression technique has been developed for more precise restorations and convenient procedures in prosthodontic treatment compared to the conventional impression technique. Along with the utilization of CAD/CAM, the introduction of digital impression technique actualizes the digitalization of dental treatments. This case is to compare two different prostheses introducing each procedure in detail; one from CAD/CAM after taking digital impression and the other from the conventional technique. A 22-year-old female visited the clinic with the chief complaint of correction of discoloration and shape on maxillary right central incisor. Due to the trauma 8 years ago, the tooth was endodontically treated with post and resin core. The treatment was planned and the procedures were conducted under the patient's consent to treat the tooth with all ceramic crowns in two different ways for comparison. In conclusion, both prostheses presented clinically acceptable results with comparing the internal fitness of two all ceramic crowns. The prosthesis from digital impression, however, showed more errors in respect of internal fitness.

Accuracy of Digital Impression Made from Different Elastomeric Impression Materials: Three-Dimensional Superimpositional Analysis (치과용 탄성 인상재를 기반으로 채득된 디지털 모형의 정확성 연구: 3차원 중첩 분석)

  • Kim, Ki-Baek;Jung, Jae-Kwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.94-100
    • /
    • 2014
  • The purpose of this study was to evaluate the accuracy of digitized elastomeric impression materials of crown abutment, using non-contact white light scanner and virtual three-dimensional superimpositional analysis. The stone models and impressions were digitized white light scanner to create three-dimensional surface models. Stone models were used as CAD reference model (CRM). The resulting point clouds (ASC file) from digitization of impressions using converting software. Discrepancies between the points in the point clouds and CRM were measured by superimpositional software. Mean and standard deviation of values of discrepancies were analyzed by one-way ANOVA and multiple comparison (${\alpha}=0.05$). The mean discrepancy between the impressions for the extra-light body (XLB), light body (LB), and heavy body (HB) group were $5.10{\pm}1.45{\mu}m$, $6.30{\pm}1.87{\mu}m$, $9.80{\pm}1.52{\mu}m$, respectively. The different impression materials affected the digitization of impressions significantly (p<0.05). As a result, digitization of elastomeric impression materials on dental scanner was influenced by material sort.

Development of latent footwear impression on porous surfaces using DL-alanine solution and 1,2-indanedione solution (DL-alanine과 1,2-indanedione을 이용한 종이에 남은 족적의 증강)

  • Hong, Sungwook;Kim, Euna;Park, Miseon;Lee, Eunhye
    • Analytical Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.303-311
    • /
    • 2017
  • A new method for obtaining the photoluminescence of footwear impression by using 1,2-indandione (1,2-IND) solution, which is a latent fingerprint-developing reagent, was studied. A binary complex of DL-alanine and 1,2-IND was prepared by spraying a DL-alanine solution and the 1,2-IND solution (an amino acid sensitive reagent) onto dry or wet origin footwear impression deposited on the surface of printed A4 paper. This binary complex reacts with the trace metal component in the footwear impression to form a ternary complex that exhibits photoluminescence. However, when 5-methylthioninhydrin (5-MTN) solution was used instead of 1,2-IND, no consistent photoluminescence was observed even under identical treatment conditions. In addition, when footwear impressions treated with DL-alanine and 1,2-IND solutions were stored under various temperature conditions (30, 40 and $50^{\circ}C$) and various humidity conditions (30 %, 40 %, 50 % and 60 % RH), the contrast between the footwear impression and the background decreased. Optimal footwear impression photoluminescence was obtained when the footwear impressions treated with DL-alanine and 1,2-IND solutions were stored at $30^{\circ}C$ and 30 % RH for 1 h. The sensitivity of the developed method was ccompared with the sensitivities of three known methods - black gelatin lifting, 2,2'-dipyridyl treatment, and 8-hydroxyquinoline treatment. The results showed that the sensitivity of the developed method was worse than that of the black gelatin lifting method but better than that of 2,2'-dipyridyl or 8-hydroxyquinoline treatment method.

The impacts of social category information (we/other) versus personality information (warm/cold) on impression formation (인상형성에 있어 사회범주 정보(우리-남)와 성격특성 정보(따뜻한-차가운)의 영향)

  • Cheong-Yeul Park;Taekyun Hur
    • Korean Journal of Culture and Social Issue
    • /
    • v.12 no.4
    • /
    • pp.55-75
    • /
    • 2006
  • Most previous research on impression formation has been examined the effects of various informations exclusively within a category, either social category or individual characteristic. The present research examined and compared the priming effects of social category information (we and other) versus personality information (warm and cold) on impression formation. In Study 1, participants primed subliminally with combinations of social category and personality information (we/warm, we/cold, other/warm, and other/cold) were asked to rate faceial pictures on the good-bad and likable-dislikable dimensions. The analysis revealed only the significant main effects of social category information but not any effects of personality information on both the impression dimensions. In Study 2 in which participants were primed with either social category or personality information exclusively, priming of social category information influenced the judgments of likable-dislikable dimension and that of personality information influenced the judgments of good-bad dimension. These results suggest that personality information influences impression in general even though its impacts may be overwritten by social categorical information. The findings were discussed with its implication of everyday's impression formation and the cultural psychological perspectives.