• 제목/요약/키워드: Impressed current method

검색결과 40건 처리시간 0.039초

국가 기간 시설물의 전식 대책(안) (A Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1609-1611
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) system of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. In this paper, the mechanism of mitigation method of DC stray current for underground metallic structures is described.

  • PDF

시멘트계 보수재료로 코팅된 강재의 부식 및 휨강성 평가 (Evaluation of Steel Corrosion and Flexural Strength Coated with Cementitious Repair Material)

  • 윤용식;김태상;김호룡;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제4권3호
    • /
    • pp.243-249
    • /
    • 2016
  • 본 연구에서는 시멘트계 보수재 코팅이 철판의 부식 저항성에 미치는 영향을 평가하가 위해 보통 철판(Normal), 용접철판(Welding), 용접 후 보수재 철판(Welding & coating)의 세 가지 경우에 대하여 7일간 ICM(Impressed Current Method)를 통하여 부식을 촉진시켰다. 이후 Faraday 법칙을 통해 얻은 이론 부식률, 실험 부식률 그리고 부식 실험 후 측정한 휨 강도를 비교 평가하였다. Normal case와 Welding case에서는 약 70% 수준의 부식률이 측정되었으며, Welding & coating case에서는 약 17%정도의 부식률이 측정되었다. 이는 시멘트계 보수재료의 코팅이 염화물 이온의 침투를 효과적으로 차단하였으며 이로 인해 부식전류의 발생이 억제되었기 때문이다. 휨 강도 역시 부식률 평가와 같은 경향을 나타내었으며 Welding & coating case에서 Welding case 대비 약 3.4배 큰 강도가 평가되었다. 시멘트계 보수재 코팅이 용접부에 시행되면 용접부 철판의 부식 차단에 효과적일 것으로 판단된다.

전기화학적 전착기법을 활용한 콘크리트의 인공 균열치유에 관한 실험적 연구 (Experimental Study on Artificial Crack Healing for Concrete Using Electrochemical Deposition Method)

  • 이창홍;송하원
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.409-417
    • /
    • 2009
  • 이 연구에서는 인공균열치유방법으로서 전기화학적 전착기법을 활용한 균열치유에 관한 실험연구를 통해 부 식모니터링의 관점에서 자기균열치유 및 인공균열치유의 비교분석을 수행하였다. 이를 위해 가압전류의 특성 분석, 갈 바닉 전류의 비교분석, 선형분극저항의 비교분석 및 치유전과 치유후의 균열 치유 향상도를 사진화상 분석기법을 통한 정량화 비교로서 수행하였다. 연구결과로부터, 가압전류 모니터링에서 고정 가압전류에 따른 전압의 결과는 시간의 경 과에 따라 일정부분까지 증가하다가 수렴하는 것을 알 수 있었고, 갈바닉 전류 측정에 의해 인공균열치유의 경우가 자 기균열치유에 비해 더욱 넓은 범위의 전류 vs. 전압 범위 분포를 보여 부식저항성을 안정화하고 있음도 확인하였다. 한 편 사진 화상 분석기법을 통해서는 인공균열치유 기법의 경우가 약 1.63배 자기균열치유에 비해 균열치유 향상효과를 가지는 것으로 분석되었다.

그라우트 품질을 고려한 텐던의 부식저항성 평가 (Evaluation of Corrosion Resistance with Grout Type and Tendon)

  • 류화성;안기홍;고경택;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권4호
    • /
    • pp.76-82
    • /
    • 2018
  • PSC 구조에서 덕트 내부의 그라우트는 텐던 부식에 효과적인 부식방어 기재이다. 본 연구에서는 일반적으로 사용되고 있는 그라우트와 낮은 물-시멘트비와 실리카 퓸을 혼입한 그라우트를 대상으로 역학적, 내구적 시험을 수행하였다. 높이 1000mm의 덕트를 이용하여 텐던 시스템을 제작하였으며, 두 가지 그라우트에 대하여 강도, 흡수율, 플로우, 블리딩, 팽창률 등을 평가하였다. 또한 내부 12.7mm 텐던에 대하여 ICM(Impressed Current Method)를 이용하여 2일 및 4일 동안 부식을 촉진시켰으며 부식량을 조사하였다. 개선된 그라우트에서는 10MPa 이상의 높은 강도와 50% 이하의 낮은 흡수율을 나타내었다. 또한 2일~4일 동안의 부식촉진실험에서 39.8%~48.2%의 뛰어난 부식감소율 나타내었다.

철근부식을 고려한 FRP Hybrid Bar 및 일반 철근을 가진 RC 보의 내력저하 평가 (Evaluation of Load Capacity Reduction in RC Beam with Corroded FRP Hybrid Bar and Steel)

  • 오경석;문진만;박기태;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.10-17
    • /
    • 2016
  • RC(Reinforced Concrete) 부재는 인장영역에서 보강재가 하중을 지지해야 하므로, 철근부식은 내구성 뿐 아니라 안전성에서도 매우 중요하다. 본 연구에서는 최근 개발된 FRP Hybrid Bar와 일반 철근을 매립한 RC 보부재를 제작하였으며, ICM(Impressed Current Method)를 적용하여 철근부식을 촉진시켰다. 기존의 이론식인 Faraday 법칙을 이용하여 부식량을 평가하였으며, 일반설계강도를 가진 콘크리트 보부재에 대하여 휨시험을 수행하였다. 일반 철근에서는 부식량이 4.9~7.8% 수준으로 평가되었으며 이에 따른 휨 저항능력은 -25.4~-50.8% 수준으로 감소하였다. FRP Hybrid Bar를 매립한 RC 보에서는 부식과 휨 저항 감소가 평가되지 않았는데, 이는 에폭시 도료로 코팅된 철근의 우수한 내부식성에 기인한다. 촉진 부식실험에서는 FRP Hybrid Bar의 우수한 내부식성 및 부착성능을 확인하였는데, 실용화를 위해서는 장기적인 침지를 통한 내구성 평가가 필요하다고 판단된다.

154kV 지중 POF 케이블의 부식방지(腐蝕防止)에 관한 연구(硏究) (A Study on the Corrosion Control and Protection of 154kV Underground Pipe-type Oil Filled (POF) Cable)

  • 이동일;김정부;정동원;김대경;이종범;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.161-165
    • /
    • 1990
  • KEPCO has experienced eight oil leakage failures due to POF cable corrosion in the 154KV underground POF cable transmission line since the line was operated in 1976. Experimentally, We have verified that the cause of the failure is electrolytic corrosion of the cable owing to subway leakage current. For the countermeasure, We adopted the total Cathodic Protection System by the use of Victim Anode, Forced Drainage Method and Impressed Current Method with polarization cell.

  • PDF

선체 부식에 의한 수중 전기장 신호 특성 모델링 기법 연구 (A Study on the Modelling Method of Underwater Electric Field Signature due to Ship's Corrosion)

  • 정현주;양창섭;전재진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.876-878
    • /
    • 2008
  • The galvanic corrosion of a vessel, or systems fitted to minimize the ship's corrosion such as ICCP(Impressed Current Cathodic Protection) system and sacrificial anodes, can lead to significant electrical current flow in the sea. The presence of vessel's current sources associated with corrosion will give rise to detectable electric field surrounding the vessel and can put it at risk from mine threats. For this reason, it is necessary to design corrosion protection systems so that they don't only prevent a hull corrosion but also minimize the electric field signature. In this paper, we describe theoretical backgrounds of underwater electric field signature due to corrosion and corrosion protection system on naval vessels and analysis results of the electric field according to ICCP anode arrangement.

  • PDF

직류전기철도의 누설전류 간섭대책(2) 분포외부전원시스템 (Mitigation of Stray Current Interference from DC Electric Railroad(2) DICCP System)

  • 하윤철;배정효;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.273-275
    • /
    • 2005
  • The national need to establish a new stray current mitigation method to protect the underground metallic infrastructures in congested downtown area forced us to design and develop the distributed impressed current cathodic protection (DICCP) system. The main purpose of this system is to replace the stray current drainage bond methods, which is widely adopted by pipeline owners in Korea. Currently, forced drainage makes up about 85% of total drainage facilities installed in Korea because polarized drainage can neither drain perfectly the stray currents during normal operation of electric vehicle nor drain the reverse current during regenerative braking at all. The forced drainage, however, has been abused as an alternative cathodic protection system, which impresses currents from rails to the pipelines and accordingly uses the rails as anodes. As a result, it is necessary to consider a new method to both cathodically protect the pipelines and effectively drain the stray currents. In this paper, we describe the design parameters and installation schemes of DICCP system that can meet these demands.

  • PDF

EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링 (Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS))

  • 우성엽;김제경;이정재;기성훈
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.651-662
    • /
    • 2022
  • 이 연구에서는 전기화학적 임피던스분광법(Electrochemical Impedance Spectroscopy, EIS)을 활용하여 콘크리트 속 철근 부식의 개시, 전파 및 이로 인한 콘크리트의 손상을 관찰하기 위한 실험을 수행하였다. 먼저, 직경 25mm, 높이 70mm 원주형 콘크리트 실험체 중심에 지름 5mm의 탄소강봉을 매입한 실험체를 제작하였다. 실험체에 사용된 콘크리트는 물-시멘트 비 0.4, 0.5, 0.6을 갖는 세 가지 배합을 제작하였다. 촉진부식시험을 수행하여 위하여 철근 콘크리트 실험체는 0.5M NaCl 수용액에 침지한 후 0C, 13C, 65C, 130C의 네 가지 수준의 전하량을 인가하였다. 이 연구에서는 부식촉진 및 이 과정에서 EIS의 주기적 모니터링을 자동화하여 실험의 효율을 향상시켰다. 이 연구의 실험 결과를 통하여 EIS 주요 특성인자를 활용하여 콘크리트 속 철근의 부식상태를 효과적으로 평가할 수 있음을 확인하였다. 전하이동저항(Rc)값은 전하인가량이 0C에서 13C로 증가함에 따라 급격히 감소하여 대략 10kΩcm2 값을 나타내었다. 하지만 부식개시 이후 전하인가량을 13C에서 130C로 증가하였을 때 Rc값의 민감도는 현저히 감소하는 것을 확인하였다. 한편 이중층용량값(Cdl)값은 전하인가량이 0C에서 130C로 증가함에 따라 대략 50×10-6μF/cm2 에서 250×10-6μF/cm2 수준으로 선형비례관계를 보였다. 이러한 결과는 Cdl 모니터링을 통하여 부식물질에 팽창에 따라 유발된 콘크리트 내부 손상의 진전을 효과적으로 평가할 수 있음을 보여준다. 이 연구의 결과는 EIS를 활용하여 콘크리트 속 철근 부식의 확산 및 이에 따른 콘크리트 손상의 실시간 모니터링을 위한 매입형 센서 및 EIS 신호 분석방법의 고도화를 위한 기본 데이터를 제공하는데 의미가 있다.

국가기간시설물의 전식대책(안) 및 그 적용 사례(1) (A Case Study(1) of Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1612-1614
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP system is described.

  • PDF