• Title/Summary/Keyword: Implantitis

Search Result 141, Processing Time 0.024 seconds

The Effects of Professional Tooth Cleaning and Plaque Control Instruction on Reduction of Peri-implantitis (전문가치면세정술과 세균막관리교육의 임플란트 주위염 감소 효과)

  • Park, Kyung-Hwa;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.163-170
    • /
    • 2012
  • The purpose of this study was determine the effects of professional tooth cleaning and plaque control instruction(PT & PCI) on reduction of peri-implantitis. A total 80 implant patients were investigated using O'Leary plague index(PI), L${\ddot{o}}$e & Silness gingival index(GI), implant bone loss(BL). While the PT & PCI was conducted by using 'Watanabe method' after scaling for the experimental group, the engine polishing and a plaque control instruction was operated by rolling method after scaling for the control group. The collected data were analyzed with t-test, ANOVA, paired t-test and stepwise multiple regression. PI and GI of the experimental group significantly decreased than the control group(p<0.05). BL, also tended to decreased in the experimental group than the control group(p=0.155). Multiple regression analysis, the factors that was highly correlated with PT & PCI on the PI and GI. According to the implant characteristics, implant location and duration were closely related to PI(p<0.05). Therefore, the PT & PCI is one of the effective methods to reduce the failure caused by the peri-implantitis. Based on this conclusion, that it would be meaningful if the proposed PT & PCI is applied to the oral health management programs of the implant patients.

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

Recent Advances of Osseointegrated Implants Removal (골유착된 임프란트 제거의 최신지견)

  • Kim, Nam Yoon
    • The Journal of the Korean dental association
    • /
    • v.54 no.4
    • /
    • pp.258-273
    • /
    • 2016
  • In spite of appropriate treatment of peri-implantitis, the peri-implant bone loss was keep going, the clinician should remove the osseointegrated implant. the conventional methods are like a extraction of natural teeth, and use of trephine drills. In these days, many exclusive instruments are invented by implant companies. these instruments can make easy, least invasive, less traumatic removal of osseointegrated implants. In generally peri-implant bone loss progress steadily less sign and symptoms that the patient do not want to remove their implants. However, the failure of dental implant is big burden to clinicians and also patients. In the dental implant treatment, there is no 'failure' but only is 'replacement' or 'change'.

  • PDF

Laser therapy in dentinal hypersensitivity and periodontal treatment (상아질 지각과민증과 치주 처치에서 레이저의 이용)

  • Namgung, Cheol;Lee, Jong-Ho;Kum, Kee-Yeon;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.307-314
    • /
    • 2014
  • Although a laser has been introduced to implant dentistry for decades, its efficacy is still open debate. The aim of this literature review is to analyze and evaluate the efficacy of laser therapy for the treatment of dentinal hypersensitivity and periodontal conditions.

The SEM and SPM Study on the Change of Machined Titanium Implant Surface following Various Laser Treatments (수종의 레이저로 임프란트 표면 처리 시 표면 형태의 변화에 대한 주사전자 및 주사탐침 현미경적 연구)

  • Kim, In-Kyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.451-463
    • /
    • 2001
  • Following the extensive use of implant, the incidence of peri-implantitis increases. Guided bone regeneration has been used for the optimal treatment of this disease. Because implant surface was contaminated with plaque and calculus, cleaning and detoxification were needed for the reosseointegration when guided bone regeneration was performed. Various mechanical and chemical methods have been used for cleaning and detoxification of implant surface, air-powder abrasive and oversaturated citrate were known to be most effective among these methods. However, these methods were incomplete because these could not thoroughly remove bacteria of implant surface, moreover deformed implant surface. Recent studies for detoxification of the implant surface using laser were going on, $CO_2$ laser and Soft Diode laser were known to be effective among these methods. The purpose of this study was to obtain clinical guide by application these laser to implant surface. 15 experimental machined pure titanium cylinder models were fabricated. The $CO_2$ laser treatment under dry, wet and hydrogen peroxide condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of models. Each groups were examined with SPM and SEM to know whether their surface was changed. The results were as follows : 1. Surface roughness and surface form weren't changed when $CO_2$ laser was usedunder dry condition(P>0.05). 2. Surface roughness and surface form weren't changed when $CO_2$ laser was used under wet condition(P>0.05). 3. Surface roughness and surface form weren't changed when $CO_2$ laser was used under hydrogen peroxide condition(P>0.05). 4. Surface roughness and surface form weren't changed when Soft Diode laser was used under toluidine blue O solution condition(P>0.05). From the result of this study, it may be concluded that the $CO_2$ laser having relatively safe pulse mode and the Soft Diode laser used with photosensitizer can be used safely to treat peri-implantitis.

  • PDF

Rehabilitation using milled-bar with attachment maxilla overdenture in a patient with peri-implantitis fixed prosthesis: A case report (임플란트 주위염이 발생한 고정성보철 환자에 상악 Milled-bar와 부착장치를 이용한 피개의치로 수복한 증례)

  • Joon-Myung Lee;So-Yeun Kim;Du-Hyeong Lee;Kyu-Bok Lee;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • There are various methods for restoring the dentition of completely edentulous patients. Removable complete dentures have the advantage of being relatively economical, but they can be uncomfortable to wear. With the introduction of implant prosthodontics, various options such as implant-supported overdentures and hybrid prostheses have become available. If there is inadequate remaining ridge or limited financial resources, an overdenture supported by a few implants with additional attachments may be more suitable. In this case, due to severe peri-implantitis and other complications, the implants were removed. Subsequently, four implants (two on each side) were placed in the maxilla and a milled-bar with attachment was fabricated for each side of the maxilla.

The importance of SPT(Supportive Periodontal Therapy) for prevention of peri-implant disease (임상가를 위한 특집 1 - Peri-implant disease를 방지하기 위한 Supportive Periodontal Therapy(SPT)의 중요성)

  • Park, Su Jung
    • The Journal of the Korean dental association
    • /
    • v.51 no.12
    • /
    • pp.630-636
    • /
    • 2013
  • During the past decade, the use of osseointegrated implants as a foundation for prosthetic replacement of missing teeth has become highly predictable and successful. SPT(Supportive Periodontal Therapy) identified as regular visits to the therapist for periodontal control and maintenance in a well-organized scheme, the number of appointments per year following a pre-designed subject-tooth/implant-site risk assessment method. Peri-implant disease was a frequent finding in subjects having natural healthy dentition and in subjects without periodontitis. Supportive periodontal program were found to be strongly related to implant survival. This study demonstrates that regular maintenance reduces the risk for peri-implant inflammation significantly as compared with irregular maintenance. This underlines the value of the SPT in enhancing the long-term outcomes of implant therapy, particularly in subjects affected by periodontitis, in order to control reinfection and limit biological complications. It is highly recommended to maintain implant patients under a strict supportive periodontal treatment protocol that might contribute to implant survival, and regular maintenance reduces the risk for periimplant inflammation significantly as compared with irregular maintenance. Ideally, patients may be informed on the beneficial effect of a regular patient-related post-therapy care before implant insertion.

Maxillary anterior fixed implant prosthesis using customized nonprecious metal casting abutment: a case report (비귀금속 주조 맞춤형 지대주를 이용한 상악 전치부 임플란트 보철수복 증례)

  • Lee, Jae-In
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.50-59
    • /
    • 2015
  • It is hard to restore and manage anterior teeth esthetically and functionally; because of peri-implantitis, not only hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also esthetic problem caused by metal abutment exposure can occur. This case presents patients using customized abutment made of Co-Cr alloy that can be made by conventional casting and compensate the shortcomings of prefabricated titanium abutments, and cement-retained prosthesis.

CLINICAL STUDY ON SUCCESS RATE OF TG OSSEOTITE IMPLANT (TG Osseotite 임플란트의 성공률에 대한 임상적 연구)

  • Oh, Sung-Hwan;Min, Seung-Ki;Chae, Young-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.39-47
    • /
    • 2005
  • The purpose of this study is to review the prognosis of the TG Osseotite implant(3i Co, USA) placed in partial edentulous area of oral cavity and to suspect the possible causes leading to failure. 124 TG Osseotite implants that had been inserted between 2000 - 2002 were followed up for 2 years(avg : 9.5 months) in function. Medical records, and radiographs were evaluated and analyzed by the over all success rate, gender and age factor, general disease, implant fixture length and diameter, implant site, bone density, and various surgical methods. Chi square test was used statistically. Of the 124 TG Osseotite implants, 9 implants(7.3%) were removed in early phase and 3 implants(2.4%) were in late phase. The cumulative survival rate was 90.2%. The failure of the TG Osseotite implant was closely related with the use of bone graft techniques such as sinus elevation or immediate implantation and not with the age, sex, general disease, implant site, bone density of implanted site. The failure of the TG Osseotite implant was well developed when it was the wide type of implant and it was inserted for single tooth replacement. The developement of peri-implantitis was the most important factor in the failure of the TG Osseotite implant.

Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

  • Rinke, Sven;Buergers, Ralf;Ziebolz, Dirk;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.329-337
    • /
    • 2015
  • PURPOSE. This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS. In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS. One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: $5.9{\pm}2.2years$), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION. Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required.