• Title/Summary/Keyword: Implant-tooth distance

Search Result 32, Processing Time 0.028 seconds

Influence of the adjacent periodontium and inter-implant distance on bone resorption around non-submerged implants;A retrospective clinical and radiographic study (인접 치주조직과 임플란트간 거리가 임플란트 주변 골흡수에 미치는 영향;임상 및 방사선사진 검사에 의한 후향적 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.535-541
    • /
    • 2004
  • The aims of the present study are firstly to investigate the amount of bone loss around non-submerged implants placed in the posterior region and secondly to investigate the relationship between inter-implant and implant-tooth distance and peri-implant bone loss. Thirty-one subjects with 60 implants were selected consecutively from the implant patient pool at the department of Chonbuk National University Hospital. To be included in the study subject, the implant should have been functioned more than 6 months after loading. Inter-implant and implant-tooth distance, distance between implant shoulder and the first bone contact with the implant(DIB) were measured from the scanning image of the radiograph of each implant. The result showed that; 1. inter-implant distance has a statistically significant relationship with DIB in Pearson correlation analysis. 2. the DIB at the implant facing surface of the implant was greater than that of tooth facing surface of the implant. Within limitation of this study, it is suggested to place an implant not too closely to adjacent implants, and the presence of a tooth adjacent to an implant may keep the level of tooth-facing surface of the implant. Further studies with a prospective design are needed to elucidate the relationship between bone changes and various dimensions around implants.

Prevalence of dental implant positioning errors: A cross-sectional study

  • Gabriel, Rizzo;Mayara Colpo, Prado;Lilian, Rigo
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.343-350
    • /
    • 2022
  • Purpose: This study evaluated the prevalence of dental implant positioning errors and the most frequently affected oral regions. Materials and Methods: A sample was obtained of CBCT images of 590 dental implants from 230 individuals who underwent diagnosis at a radiology center using cone-beam computed tomography from 2017 to 2020. The following variables were considered: thread exposure, violation of the minimum distance between 2 adjacent implants and between the implant and tooth, and implant contact with anatomical structures. Descriptive data analysis and the Pearson chi-square test(P<0.05) were performed to compare findings according to mouth regions. Results: Most (74.4%) of the 590 implants were poorly positioned, with the posterior region of the maxilla being the region most frequently affected by errors. Among the variables analyzed, the most prevalent was thread exposure (54.7%), followed by implant contact with anatomical structures, violation of the recommended distance between 2 implants and violation of the recommended distance between the implant and teeth. Thread exposure was significantly associated with the anterior region of the mandible (P<0.05). The anterior region of the maxilla was associated with violation of the recommended tooth-implant distance (P<0.05) and the recommended distance between 2 adjacent implants(P<0.05). Implant contact with anatomical structures was significantly more likely to occur in the posterior region of the maxilla (P<0.05). Conclusion: Many implants were poorly positioned in the posterior region of the maxilla. Thread exposure was particularly frequent and was significantly associated with the anterior region of the mandible.

Horizontal alteration of anterior alveolar ridge after immediate implant placement: A retrospective cone beam computed tomography analysis

  • Hyun, Young Keun;Lee, Chung Yun;Keerthana, Subramanian;Ramasamy, Selvaponpriya;Song, So-Yeon;Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.117-125
    • /
    • 2021
  • PURPSE. The aim of this study was to evaluate the labio-lingual alterations of the alveolar bone where the implant was placed immediately after tooth extraction. MATERIALS AND METHODS. Implants were placed immediately after tooth extraction on anterior alveolar ridges in the maxilla and mandible. The pinguide system was used to help determine the location and path of implants during the surgical process. The horizontal distance from implants to the outer border of alveolar bone was measured at the rim and middle of the implants in the cone beam computed tomography images. The alteration of alveolar bone was evaluated comparing the horizontal distances measured immediately after surgery and 3 months after surgery. RESULTS. The results show that more resorption occurred towards the labial bone than the lingual bone in the maxilla. A similar amount of labial and lingual bone resorption was observed in the mandible. CONCLUSION. Considering the horizontal alteration of alveolar bone, labio-lingual positioning of the implant towards the lingual bone in the maxilla and at the center of the alveolar ridge in the mandible is recommended when it is placed immediately after tooth extraction.

COMPLICATIONS OF THE IMPLANT-SUPPORTED POSTERIOR MANDIBULAR SINGLE RESTORATIONS WITH MESIAL CANTILEVER (하악구치 임플란트 지지 단일수복에서 근심 캔틸레버가 임플란트 합병증에 미치는 영향)

  • Shin, He-Sung;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.248-252
    • /
    • 2009
  • Purpose: This retrospective study was performed to analyze the relationship between complications of the posterior mandibular single crowns and distance from the adjacent teeth to the implant. Subjects and Methods: Of the patients who presented Ewha Womans University Mokdong Hospital & Yonsei University Dental Hospital with missing of the posterior mandibular molar and restored with implant-supported 18 Single crowns between 1996 thru 2007, 115 patients had been followed after crown delivery. The subjects were divided into complication-followed group and a control without any problems. The distance from the most distal tooth to the implant were measured. The prosthetic & biologic complications were reviewed by the cantilever distance and analyzed by abutment type, age & gender statistically using SAS version 9.1 (SAS Inc., USA). Results and Conclusion The results were as follows; 1) The posterior mandibular single crown with cantilever showed higher incidence of follow-up complications upon logistic analysis (p<0.05). 2) The prosthetic and biologic complications are related with the cantilever distance with 2.1 odds ratio and 3.39 cut-off value of specificity & sensitivity by SPSS 12.0. 3) The complications are neither significant in abutment types nor age & gender.

Sinus floor augmentation at the time of tooth removal (상악 구치부의 발치와 동시에 시행하는 상악동저 증강술을 이용한 임프란트 증례)

  • Kim, Min-Kue;Jin, Min-Ju;Ahn, Eun-Joo
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.647-653
    • /
    • 2007
  • Rapid crestal bone resorption following maxillary tooth loss is further accentuated in the posterior regions because of pneumatization and enlargement of the maxillary sinuses. A treatment rationale that allows preservation and augmentation of vertical available bone at the time of posterior maxil-lary tooth extraction may offer numerous therapeutic benefits which are more short courses of ther-apy and no needs of additional surgical augmentation. The present study comprised 3 patients who had 4 posterior maxillary teeth with no evident bone between the tooth apex and sinus floor, as estimated through preoperative radiographic analysis. Sinus floor augmentation at the time of tooth extraction was chosen for the ltreatment of these patients. After the tooth was carefully extracted, the empty alveolus was thoroughly debrided and a trephine approach was performed. Particulated autogenous bone was gently pushed beyond the empty alveolus to elevate the sinus membrane using an osteotome. The distance between bone crest and si-nus floor was radiographically estimated 4 months after the first procedure. Another procedure was then carried out to place the implants of 11 mm length without another augmentation procedure. All implant were clinically stable, with no sign of infection. The presented surgical procedure performed at the time of extraction of posterior maxillary teeth in close proximity to the sinus floor allowed placement of implants of proper length.

STATISTICAL STUDY ON OPTIMAL PLACEMENT OF IMMEDIATE DENIAL IMPLANTATION USING DENTA $SCAN^R$ (Denta $Scan^R$을 이용한 즉시 임플랜트 시술시 최적의 식립 위치 대한 통계적 연구)

  • Shin, Kwang-Ho;Lee, Jai-Bong;Hwang, Byung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.552-560
    • /
    • 2000
  • Purpose : The purpose of this study was to determine proper position and angulation of an implant for immediate implantation. Materials and Method : From the years 1997 to 2000. 52 Denta $scan^R$ views, 22 upper and 32 lower jaw with an average age of 43 and 40 respectively, were investigated, which comprise intact upper and lower 6 anterior teeth and premolars. On the Denta $scan^R$, the optimal placement for the immediated implantation was simulated. The measuring methods included 1) Angulation difference between tooth long axis and alveolar bone process. 2) Angulation difference of long axis between tooth and installing fixture 3) Distance between center of tooth at cervical area and center of fixture. 4) Distance from root apex to the bone limit of vital structure. One sample t-test was used for statistical analysis. Result : The results were as follows. 1) At the maxillary central incisor and lateral incisor, angulation difference of long axis between tooth and installing fixture was respectively 0.5 and 3.2 degrees with the fixture center's palatally positioned 2mm apart from tooth center. 2) At the lower anterior 6 teeth, that was about $-2.8^{\circ}\;to\;-4.6^{\circ}$ with the fixture center's lingually positioned 1mm apart from tooth center. 3) At the maxillary canine and premolar, that was respectively $11.8^{\circ}\;and \;7.2^{\circ}$ with the fixture center palatally positioned $2\sim2.4mm$ apart from tooth center. 4) At the lower premolar area, that was about $0^{\circ}\;to\;2^{\circ}$ with the fixture center's lingually positioned $0.5{\sim}1mm$ apart from tooth center. 5) Distance from root apex to the bone limit of vital structure, at the maxillary anterior and premolars. was the range of 10 to 12mm, and at the mandibular anterior teeth and the 1st premolar, that was the range of 18 to 20mm. Conclusion : The proper implant position of maxillary anterior and premolar teeth is as paralleled as or more buccally angulated than long axis of tooth with the fixture center's palatally positioned. In mandiblular anterior region, long axis of implants is lingully angulated compared with long axis of tooth and in premolar, almost parelleled with long axis of tooth and alveolar process.

  • PDF

An analysis on the factors responsible for relative position of interproximal papilla in healthy subjects

  • Kim, Joo-Hee;Cho, Yun-Jung;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.160-167
    • /
    • 2013
  • Purpose: This study examined the factors that can be associated with the appearance of the interproximal papilla. Methods: One hundred and forty-seven healthy interproximal papillae between the maxillary central incisors were examined. For each subject, a digital photograph and periapical radiograph of the interdental embrasure were taken using a 1-mm grid metal piece. The following parameters were recorded: the amount of recession of the interproximal papilla, contact point-bone crest distance, contact point-cemento-enamel junction (CEJ) distance, CEJ-bone crest distance, inter-radicular distance, tooth shape, embrasure space size, interproximal contact area, gingival biotype, papilla height, and papilla tip form. Results: The amount of recession of the interproximal papilla was associated with the following: 1) increase in contact point-bone crest, contact point-CEJ, and CEJ-bone crest distance; 2) increase in the inter-radicular distance; 3) triangular tooth shape; 4) decrease in the interproximal contact area length; 5) increase in the embrasure space size; and 6) flat papilla tip form. On the other hand, the amount of gingival recession was not associated with the gingival biotype or papilla height. In the triangular tooth shape, the contact point-bone crest distance and inter-radicular distance were longer, the interproximal contact area length was shorter, and the embrasure space size was larger. The papilla tip form became flatter with increasing inter-radicular distance and CEJ-bone crest distance. Conclusions: The relative position of the interproximal papilla in healthy subjects was associated with the multiple factors and each factor was related to the others. A triangular tooth shape carries a higher risk of recession of the interproximal papilla because the proximal contact point is positioned more incisally and the bone crest is positioned more apically. This results in an increase in recession of the interproximal papilla and flat papilla tip form.

THE USEFULNESS OF IMMEDIATE IMPLANTATION USING $BIO-OSS^{(R)}$ AND $BIO-GIDE^{(R)}$. IN $ITI^{(R)}$. IMPLANT SYSTEM ($ITI^{(R)}$ implant system에 있어서 $Bio-Oss^{(R)}$$Bio-Gide^{(R)}$를 이용한 발치 후 즉시 임플란트의 유용성)

  • Park, Kwan-Soo;Yoon, Kyu-Ho;Cheong, Jeong-Kwon;Shin, Jae-Myung;Hong, Sung-Chul;Jeon, In-Seong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.1
    • /
    • pp.58-67
    • /
    • 2006
  • In the recent studies, many authors have reported that the success rate of immediate implantation has no difference compared to conventional staged implantation. Although the immediate implantation has many advantages over conventional approach, many clinicians don't seem to practice because they think that most of the extraction sockets will have some bony gab with defects around implant and that this situation makes the result of immediate implantation unpredictable. We clinically analyzed 23 implanted sites of 18 patients treated with immediate implantation in our hospital from September 2003 to January 2004. The $ITI^{(R)}$. dental implant system was used and GBR procedure with $Bio-Oss^{(R)}$. and $Bio-Gide^{(R)}$. was done simultaneously. The pre & post-op. measurements were recorded such as alveolar crest-adjacent tooth CEJ distance, gingival crest-adjacent tooth CEJ distance, existence of periapical lesion, vertical defect around the extraction socket, horizontal defect around the extraction socket, probing depth, radiologic change of alveolar crest height. We report a positive outcome about immediate implantation with review of literatures.

Location of maxillary intraosseous vascular anastomosis based on the tooth position and height of the residual alveolar bone: computed tomographic analysis

  • Yang, Seung-Min;Kye, Seung-Beom
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.2
    • /
    • pp.50-56
    • /
    • 2014
  • Purpose: The aims of this study were to measure the distance of the intraosseous vascular anastomosis in the anterolateral wall of the maxillary sinus from different reference points, and to correlate the location of the intraosseous vascular anastomosis with the tooth position and the residual bone height of the maxilla. Methods: Computed tomography (CT) images were taken from 283 patients undergoing dental implants placement in the posterior maxilla. Three horizontal lines were drawn at the ridge crest, maxillary sinus floor, and the position of the anastomosis. A vertical second line at the center of each tooth was drawn perpendicular to the horizontal lines. The distance from the ridge crest to the maxillary sinus floor and the distance from the maxillary sinus floor to the bony canal were measured from the intersections of the horizontal and vertical lines. The residual alveolar bone height was used to categorize three groups: group 1,<4 mm; group 2, between 4 and 8 mm; and group 3, >8 mm. Results: The residual bone height values of different tooth positions were significantly different (P=0.0002). The distance from the maxillary sinus floor to the intraosseous vascular anastomosis was significantly different between groups 1 and 3 (P=0.0039). At the molar sites, a moderate negative correlation was found between the residual bone height and the distance from the maxillary sinus floor to the intraosseous anastomosis. The distances of the alveolar ridge crest and the maxillary sinus from the intraosseous vascular anastomosis were not significantly different between sexes. Conclusions: Within the limitations of this study, sites with a higher residual bone height in the molar regions were at a relatively high risk of artery damage during window osteotomy preparation; therefore, we recommend taking more precautions when using a lateral approach for sinus elevation.

Supraeruption as a consideration for implant restoration

  • Lee, Bo-Ah;Kim, Byoungheon;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.4
    • /
    • pp.260-267
    • /
    • 2020
  • Purpose: The aim of this study was to compare the prevalence, amount, and rate of supraeruption of the maxillary second molar according to sex, age, and history of periodontitis. Methods: Data were collected retrospectively from the charts and panoramic radiographs of 65 patients who were scheduled to undergo implant placement at the site of the mandibular second molar. The amount of supraeruption of the maxillary second molar and the alveolar bone level of the neighboring teeth were measured on digital panoramic radiographs. The prevalence was evaluated in each group, and univariate and multivariate logistic regression analyses were used to identify factors influencing the prevalence of supraeruption. The amount and the rate of supraeruption were compared between pairs of groups using the Mann-Whitney U test. For all tests, P values <0.05 were considered to indicate statistical significance. Results: Supraeruption occurred in 78% of the patients. The prevalence of supraeruption was affected by sex, age, and history of periodontitis. The mean amount of supraeruption was 0.91 mm and the mean rate of supraeruption was 0.14 mm/month. The amount and the rate of supraeruption showed no significant differences according to sex, age, or the distance from the cementoenamel junction to the alveolar bone crest (P>0.05). Conclusions: These results show that the amount of supraeruption on the maxillary second molar was similar to the thickness of the enamel on the occlusal surface. When a single implant is scheduled to be placed on the mandibular second molar, supraeruption of the antagonist should be considered.