• 제목/요약/키워드: Implant-supported fixed-prosthesis

검색결과 136건 처리시간 0.022초

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.

개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례 (Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system))

  • 홍태영;김만용;윤준호
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.423-430
    • /
    • 2016
  • 임플란트 보철물은 나사 유지형 보철물과 시멘트 유지형 보철물로 나눌 수 있다. 각 방법은 장점과 함께 임플란트를 유지 관리하는데 불리한 단점을 가지고 있다. 이러한 단점을 극복하기 위해 개선된 설측 고정 나사 시스템(T-screw system)이 개발되었다. T-screw system은 설측 방향의 나사를 이용하여 임플란트 보철물을 유지하는 방법으로, 보철물의 탈부착이 쉽고, 수동적 적합이 가능하며, 심미적이고 기능적인 교합면을 형성할 수 있다는 장점이 있다. 기존의 수평 나사를 이용한 보철은 기공 과정이 어려워 다수 유닛의 보철물의 경우 제작이 쉽지 않았고, 완전 도재를 이용한 보철물에서는 사용할 수 없다는 한계를 가지고 있었다. 본 증례에서 T-screw system을 이용하여 임플란트 보철물을 제작함으로써 유지 관리가 용이하고 심미적, 기능적으로 우수한 결과를 얻었다. 또한 다수 유닛의 임플란트 보철 및 완전 도재를 이용한 임플란트 보철에서 T-screw system을 이용하는 방법을 보고하고자 한다.

An implant-supported removable partial denture on milled bars to compromise the inadequate treatment plan: a clinical report

  • Kim, Jee-Hwan;Lee, Jae-Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권2호
    • /
    • pp.58-60
    • /
    • 2010
  • Presurgical prosthetic treatment planning is critical for the success of the implant prosthesis. Inadequate treatment plan, due to insufficient discussion between prosthodontist, and surgeon, may result in poor prognosis. A 26-year-old male patient was referred for prosthodontic treatment after implant was placed in the area of teeth #17,16, 22, 25 and 27, without adequate discussion nor the treatment planning between oral surgeon and prosthodontist. It was found that the patient had two hopeless teeth, and a severely resorbed alveolar ridge. Additional tooth extraction was needed and the type of definitive prosthesis was shifted from fixed type to removable one. Proper pre-surgical treatment planning is essential for the good prognosis. Implant-supported removable prosthesis on milled bars may be a useful treatment option in patients with incorrect angled placement on severely resorbed alveolar ridge.

적합도에 따른 ITI 임플란트 지지 고정성 국소의치의 삼차원 유한요소 분석 (Three Dimensional Finite Element Analysis on ITI Implant Supported Fixed Partial Dentures with Various Fitting Accuracy)

  • 최민호;이일권;김유리;조혜원
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.75-87
    • /
    • 2006
  • The purpose of this study was to investigate the effects of prostheses misfit, cantilever on the stress distribution in the implant components and surrounding bone using three dimensional finite element analysis. Two standard 3-dimensional finite element models were constructed: (1) 3 ITI implant supported, 3-unit fixed partial denture and (2) 3 ITI implant supported, 3-unit fixed partial denture with a distal cantilever. variations of the standard finite element models were made by placing a $100{\mu}m$ or $200{\mu}m$ gap between the fixture, the abutment and the crown on the second premolar and first molar. Total 14 models were constructed. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the distal marginal ridge of the distal molar. von Mises stresses were recorded and compared in the crowns, abutments, crestal compact bones, and trabecular bones. The results were obtained as follows: 1. In the ITI implant system, cement-retained prostheses showed comparatively low stress distributions on all the implant components and fixtures regardless of the misfit sizes under vertical loading. The stresses were increased twice under oblique loading especially in the prostheses with cantilever, but neither showed the effects of misfit size. 2. Under the oblique loading and posterior cantilever, the stresses were highly increased in the crestal bones around ITI implants, but effects of misfit were not shown. Although higher stresses were shown on the apical portion of trabecular bones, the effects by misfit were little and the stresses were increased by the posterior cantilever. 3. When the cement loss happened in the ITI implant supported FPD with misfit, the stresses were increased in the implant componets and supporting structures.

골유착성 임프란트와 자연치를 이용한 고정성 국소의치에서 응력분산 및 충격흡수에 관한 유한요소법적 응력분석 (A FINITE ELEMENT STRESS ANALYSIS OF THE STRESS DISTRIBUTION AND THE SHOCK ABSORPTION IN AN OSSEOINTEGRATED IMPLANT-NATURAL TOOTH SUPPORTED FIXED PARTIAL DENTURE)

  • 정창모;이호용
    • 대한치과보철학회지
    • /
    • 제30권4호
    • /
    • pp.582-610
    • /
    • 1992
  • The long-term success of any dental implant is dependent upon the optimization of stresses which occur during oral function and parafunction. Especially, it has been suggested that there is an unique set of problems associated with joining an osseointegrated implant and a natural tooth with a fixed partial denture. For this particular case, although many literatures suggest different ways to avoid high stress concentrations on the bone surrounding the implant under static and dynamic loading conditions, but few studies on the biomechanical efficacy of each assertion have been reported. The purpose of this investigation was to evaluate the efficacies of clinically suggested methods on stress distribution under static load and shock absorption under dynamic load, using two dimensional finite element method. In FEM models of osseointegrated implant-natural tooth supported fixed partial dentures, calculations were made on the stresses in surrounding bone and on the deflections of abutments and superstructure, first, to compare the difference in stress distribution effects under static load by the flexure of fastening screw or prosthesis, or intramobile connector, and second, to compare the difference in the shock absorption effects under dynamic load by intramobile connector or occlusal veneering with composite resin. The results of this analysis suggest that : 1. Under static load condition, using an implant design with fastenign screw connecting implant abutment and prosthesis or increasing the flexibility of fastening screw, or increasing the flexibility of prosthesis led to the .increase in height of peak stresses in cortical bone surrounding the implant, and has little effect on stress change in bone around the natural tooth. 2. Under static load condition, intramobile connector caused the substantial decrease in stress concentration in cortical bone surrounding the implant and the slight increase in stress in bone around the natural tooth. 3. Under dynamic load condition, both intramobile connector and composite resin veneering showed shock absorption effect on bone surrounding the implant and composite resin veneering had a greater shock absorption effect than intramobile connector.

  • PDF

Effect of repetitive firing on passive fit of metal substructure produced by the laser sintering in implant-supported fixed prosthesis

  • Altintas, Musa Aykut;Akin, Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.167-172
    • /
    • 2020
  • PURPOSE. The aim of the present study was to investigate the passive fit of metal substructure after repetitive firing processes in implant-supposed prosthesis. MATERIALS AND METHODS. Five implants (4 mm diameter and 10 mm length) were placed into the resin-based mandibular model and 1-piece of screw-retained metal substructure was produced with the direct metal laser sintering (DMSL) method using Co-Cr compound (n = 10). The distance between the marked points on the multiunit supports and the marginal end of the substructure was measured using a scanning electron microscope (SEM) at each stage (metal, opaque, dentin, and glaze). 15 measurements were taken from each prosthesis, and 150 measurements from 10 samples were obtained. In total, 600 measurements were carried out at 4 stages. One-way ANOVA test was used for statistical evaluation of the data. RESULTS. When the obtained marginal range values were examined, differences between groups were found to be statistically significant (P<.001). The lowest values were found in the metal stage (172.4 ± 76.5 ㎛) and the highest values (238.03 ± 118.92 ㎛) were determined after glaze application. When the interval values for groups are compared with pairs, the differences between metal with dentin, metal with glaze, opaque with dentin, opaque with glaze, and dentin with glaze were found to be significant (P<.05), whereas the difference between opaque with metal was found to be insignificant (P=.992). CONCLUSION. Passive fit of 1-piece designed implant-retained fixed prosthesis that is supported by multiple implants is negatively affected by repetitive firing processes.

임플란트 즉시 식립에 의한 연속된 상악 전치부의 심미적 수복 증례 (Esthetic restoration in continuous maxillary anterior area using immediate implant placement: A case report)

  • 이예찬;심준성;이재훈;이근우
    • 대한치과보철학회지
    • /
    • 제55권4호
    • /
    • pp.403-409
    • /
    • 2017
  • 상악 전치부를 발치 해야 하는 경우, 즉시 식립을 통한 임플란트 고정성 보철물의 수복을 고려할 수 있다. 이 경우, 수술 횟수 및 치료기간의 감소, 흡수가 일어나지 않은 잔존 골상에 식립이 가능하다는 장점이 있으나, 연속된 상악 전치부인 경우 임플란트와 임플란트간 거리에 대한 고려 및 예지성 있는 치료를 위한 정확한 진단 및 치료계획의 수립이 추가적으로 고려되어야 한다. 본 증례에서는 63세 남환의 잔존치근을 발거 후 연장된 상악 전치부에 골이식을 동반한 2개의 임플란트 즉시 식립 및 임시 보철물을 장착 후, 임플란트 고정성 보철물로 수복하여 심미적, 기능적으로 만족할만한 임상 결과를 보였기에 이를 보고하는 바이다.

O-ring abutment를 이용한 Implant over denture의 제작 (Implant supported over denture with O-ring abutment)

  • 이성욱;이정환;박효련
    • 대한치과기공학회지
    • /
    • 제26권1호
    • /
    • pp.209-216
    • /
    • 2004
  • The purpose of this study is to introduce how to make implant supported over denture with Oring. Many kinds of attachments have used to dental restorations. The application of attachment has widely increased implant fixed prosthesis and implant supported over denture. In order that implant supported over denture have properly retention, generally used O-ring, magnetic, bar attachment. O-ring give us an advantage that is required more minimum vertical dimension than bar-type and easily replace with new part. When we make these prosthesis using O-ring, Bar, Ball attachment, we should following procedures. Strong occlusion force leads to fracture of over denture because part of functional mechanism as implant abutment or attachment is spaced. Clips are regularly activated. O-ring and springs are changed every year. The pattern of resorption should be carefully monitored and compensated for by relining procedures. If the over denture appears to rest on the bar or the ball attachments, relining should be performed and clips/caps should be changed.

  • PDF

적합도가 다른 임플랜트 지지 보철물의 삼차원적 응력 분석 (Three dimensional stress analysis of implant-supported prosthesis with various misfit)

  • 양홍서;정현주;박영준;박상원
    • 구강회복응용과학지
    • /
    • 제17권4호
    • /
    • pp.307-314
    • /
    • 2001
  • To evaluate the effect of misfit in two implant-supported fixed partial dentures in the posterior of the mandible, variations of the standard finite element models were made by changing the location of the gap as follows: 1) no gap present; 2) located between the gold cylinder and the abutment on the distal implant; 3) gap located between the gold cylinder and the abutment on the mesial implant. The results of this study were as follows: 1. When the location of the gap was close to the load applied on the prosthesis, the stress in the prosthesis, implant components and surrounding bone increased. 2. The presence of cantilever increased the stress in the prosthesis, implant and surrounding bone significantly, regardless of the presence of the gap. 3. When there was a gap between the prosthesis and abutment, the stress in the bone around the implant increased. 4. When passive fit was achieved, the stress was distributed widely in each component with less peak stress in each component. 5. The inner structures of the implant components, the gold screw and the abutment screw bear more stress when the prosthesis did not exhibit passive fit with the abutments than when passive fit was present.

  • PDF

상악 완전 무치악 환자의 CAD/CAM 을 이용한 임플란트 식립(NobelGuide$^{TM}$) 및 즉시하중 후 고정성 보철수복 증례 (Implant Supported Fixed Restoration for Maxillary Edentulism using CAD/CAM Guided Implant Surgery (NobelGuide$^{TM}$) and Immediate Loading)

  • 허윤혁;이양진;김대곤;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제28권4호
    • /
    • pp.423-439
    • /
    • 2012
  • NobelGuide$^{TM}$ 임플란트 시스템은 골량과 골질을 수술 전에 판단하여 점막을 젖히지 않고 미리 계획된 스텐트와 보철물을 이용하여 즉시하중을 부여하는 CAD/CAM 기반의 임플란트 보철 치료방법이다. 환자의 불편감을 최소화하여 미리 예측 가능한 위치에 임플란트를 식립함으로써 술 후 합병증 및 보철과정을 간소화 할 수 있는 장점이 있다. 본 증례의 환자는 56세 남성으로 상,하악 부분 무치악 상태였으며, 상악전치부 보철물 탈락과 하악 전치가 흔들린다는 주소로 내원하였다. 이에 상악 잔존치 모두와 하악 4전치 발거 및 치주치료를 실시한 뒤 임시 의치를 6개월간 사용하여 발치와 치유 및 의치 적응여부를 평가하였다. 골량은 충분하다고 판단되었고 환자의 협조도와 경제적인 여건, 전신건강 등 여러 사항이 양호하여 CAD/CAM 기반의 수술템플렛을 이용한 무판막 수술을 통해, 미리 제작된 임시 고정성 보철물로 즉시하중을 부여하는 상악 NobelGuide$^{TM}$ 임플란트 시스템을 계획하였다. 사용중인 임시의치를 이용하여 제작한 방사선 스텐트로 CT를 촬영하고, computer based planning (Procera$^{(R)}$ software)을 통해 3차원적인 골형상과 각 부위별 단면상을 참고하여 상악에 8개의 임플란트 식립체를 생역학적 관점 및 골조건을 고려하여 분산 배치하였다. 미리 제작된 임시 고정성 보철물을 임플란트 수술 후 즉시 장착 및 하중을 부여하여 기능하도록 하였으며 6개월 후 골유착 정도를 평가한 뒤 금속구조물을 이용한 최종 보철물을 제작하였다. 하악의 경우 전치부 도재전장주조금속관과 우측 구치부 임플란트 보철물 제작을 통해 상, 하악 치료를 마무리하였다.