1 |
Campbell SD, Sirakian A, Pelletier LB, Giordano RA. Effects of firing cycle and surface finishing on distortion of metal ceramic castings. J Prosthet Dent 1995;74:476-81.
DOI
|
2 |
Ando N, Hakamura K, Namiki T, Sugata T, Suzuki T, Moriyama K. Deformation of porcelain bonded gold alloys. J Jpn Soc Appar Mater 1972;13:237-48.
|
3 |
Dederich DN, Svare CW, Peterson LC, Turner KA. The effect of repeated firings on the margins of nonprecious ceramometals. J Prosthet Dent 1984;51:628-30.
DOI
|
4 |
Hamaguchi H, Cacciatore A, Tueller VM. Marginal distortion of the porcelain- bonded-to-metal complete crown: an SEM study. J Prosthet Dent 1982;47:146-53.
DOI
|
5 |
DeHoff PH, Anusavice KJ. Effect of metal design on marginal distortion of metal-ceramic crowns. J Dent Res 1984;63:1327-31.
DOI
|
6 |
Harish V, Mohamed Ali SA, Jagadesan N, Mohamed I, Senthil S, Debasish B, Huda F, Priyanka. Evaluation of internal and marginal fit of two metal ceramic system - in vitro study. J Clin Diag Res 2014;8:53-6.
DOI
|
7 |
Pompa G, Di Carlo S, De Angelis F, Cristalli MP, Annibali S. Comparison of conventional methods and laser-assisted rapid prototyping for manufacturing fixed dental prostheses: An in vitro study. Biomed Res Int 2015;2015:318097.
|
8 |
Castillo-Oyague R, Osorio R, Osorio E, Sanchez-Aguilera F, Toledano M. The effect of surface treatments on the microroughness of laser-sintered and vacuum-cast base metal alloys for dental prosthetic frameworks. Microsc Res Tech 2012;75:1206-12.
DOI
|
9 |
Ortorp A, Jonsson D, Mouhsen A, Vult von Steyern P. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. Dent Mater 2011;27:356-63.
DOI
|
10 |
Xu D, Xiang N, Wei B. The marginal fit of selective laser melting-fabricated metal crowns: an in vitro study. J Prosthet Dent 2014;112:1437-40.
DOI
|
11 |
Iseri U, Ozkurt Z, Kazazoglu E. Shear bond strengths of veneering porcelain to cast, machined and laser-sintered titanium. Dent Mater J 2011;30:274-80.
DOI
|
12 |
Xiang N, Xin XZ, Chen J, Wei B. Metal-ceramic bond strength of Co-Cr alloy fabricated by selective laser melting. J Dent 2012;40:453-7.
DOI
|
13 |
Almeida e Silva JS, Erdelt K, Edelhoff D, Araujo E, Stimmelmayr M, Vieira LC, Guth JF. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 2014;18:515-23.
DOI
|
14 |
Anusavice KJ, Carroll JE. Effect of incompatibility stress on the fit of metal-ceramic crowns. J Dent Res 1987;66:1341-5.
DOI
|
15 |
Rungruanganunt P, Taylor T, Eckert SE, Karl M. The effect of static load on dental implant survival: a systematic review. Int J Oral Maxillofac Implants 2013;28:1218-25.
DOI
|
16 |
Sailer I, Muhlemann S, Zwahlen M, Hammerle CH, Schneider D. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res 2012;23:163-201.
DOI
|
17 |
Wittneben JG, Millen C, Bragger U. Clinical performance of screw- versus cement-retained fixed implant-supported reconstructions-a systematic review. Int J Oral Maxillofac Implants 2014;29:84-98.
DOI
|
18 |
Millen C, Bragger U, Wittneben JG. Influence of prosthesis type and retention mechanism on complications with fixed implant-supported prostheses: a systematic review applying multivariate analyses. Int J Oral Maxillofac Implants 2015;30:110-24.
DOI
|
19 |
Al-Otaibi HN, Akeel RF. The effects of two torque values on the screw preload of implant-supported prostheses with passive fit or misfit. Int J Oral Maxillofac Implants 2014;29:1058-63.
DOI
|
20 |
Ucar Y, Akova T, Akyil MS, Brantley WA. Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns. J Prosthet Dent 2009;102:253-9.
DOI
|
21 |
Witkowski S. CAM in dental technology. Quintessence Dent Technol 2005;128:169-84.
|
22 |
Wu L, Zhu H, Gai X, Wang Y. Evaluation of the mechanical properties and porcelain bond strength of cobalt-chromium dental alloy fabricated by selective laser melting. J Prosthet Dent 2014;111:51-5.
DOI
|
23 |
Shillingburg HT, Sather DA, Wilson EL, Cain JR, Mitchell DL, Blanco LJ, Kessler JC. Fundamentals of fixed prosthodontics. Illinois; Quintessence Publishing Company; 2010.
|
24 |
Yannikakis S, Prombonas A. Improving the fit of implant prosthetics: an in vitro study. Int J Oral Maxillofac Implants 2013;28:126-34.
DOI
|
25 |
Colpani JT, Borba M, Della Bona A. Evaluation of marginal and internal fit of ceramic crown copings. Dent Mater 2013;29:174-80.
DOI
|
26 |
Zeng L, Zhang Y, Liu Z, Wei B. Effects of repeated firing on the marginal accuracy of Co-Cr copings fabricated by selective laser melting. J Prosthet Dent 2015;113:135-9.
DOI
|
27 |
Quante K, Ludwig K, Kern M. Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology. Dent Mater 2008;24:1311-5.
DOI
|
28 |
Lakhani SA, Ercoli C, Moss ME, Graser GN, Tallents RH. Influence of cold working and thermal treatment on the fit of implant-supported metal-ceramic fixed partial dentures. J Prosthet Dent 2002;88:159-69.
DOI
|
29 |
Gemalmaz D, Berksun S, Kasapoglu C, Alkumru HN. Distortion of metal-ceramic fixed partial dentures resulting from metal-conditioning firing. Quintessence Int 1996;27:193-201.
|
30 |
Gemalmaz D, Alkumru HN. Marginal fit changes during porcelain firing cycles. J Prosthet Dent 1995;73:49-54.
DOI
|
31 |
Balkaya MC, Cinar A, Pamuk S. Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems. J Prosthet Dent 2005;93:346-55.
DOI
|
32 |
Shillingburg HT Jr, Hobo S, Fisher DW. Preparation design and margin distortion in porcelain-fused-to-metal restorations. J Prosthet Dent 1973;29:276-84.
DOI
|
33 |
DeHoff PH, Anusavice KJ, Boyce RJ. Analysis of thermallyinduced stresses in porcelain-metal systems. J Dent Res 1983;62:593-7.
DOI
|