• Title/Summary/Keyword: Implant-abutment

Search Result 505, Processing Time 0.023 seconds

Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial

  • Kim, Jin-Cheol;Lee, Jungwon;Kim, Sungtae;Koo, Ki-Tae;Kim, Hae-Young;Yeo, In-Sung Luke
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.147-154
    • /
    • 2019
  • PURPOSE. This study aimed to evaluate the effect of two different implant-abutment connection structures with identical implant design on peri-implant bone level. MATERIALS AND METHODS. This clinical study was a patient-blind randomized controlled trial following the CONSORT 2010 checklists. This trial was conducted in 24 patients recruited between March 2013 and July 2015. Implants with internal friction connection were compared to those with external hex connection. One implant for each patient was installed, replacing the second molar. Implant-supported crowns were delivered at four months after implant insertion. Standardized periapical radiographs were taken at prosthesis delivery (baseline), and one year after delivery. On the radiographs, distance from implant shoulder to first bone-to-implant contact (DIB) and peri-implant area were measured, which were the primary and secondary outcome, respectively. RESULTS. Eleven external and eleven internal implants were analyzed. Mean changes of DIB from baseline to 1-year postloading were 0.59 (0.95) mm for the external and 0.01 (0.68) mm for the internal connection. Although no significant differences were found between the two groups, medium effect size was found in DIB between the connections (Cohen's d = 0.67). CONCLUSION. Considering the effect size in DIB, this study suggested the possibility of the internal friction connection structure for more effective preservation of marginal bone.

A Finite element stress analysis of abutment screw according to the implant abutment material (임플란트 지대주 재질에 따른 지대주나사의 유한요소 응력 분석)

  • Kim, Nam-Sic;Lee, Myung-Kon;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Purpose: The present study was to determine the stress distribution of an abutment screw according to implant abutment material. Methods: This study was a tightening torque 10 Ncm, 20 Ncm, set to 30 Ncm, and a titanium alloy (Ti-6Al-4V), PEEK (polyetheretherketone), Endoligns (60% Carbon Fiber Reinforced PEEK) material of the custom abutment titanium alloy (Ti-6Al-4V) the stress distribution in the material of the abutment screw will be evaluated by the finite element analysis. Results: Abutment screw most stress has been concentrated on the interface between the fixture and the abutment was also part of the interface that the threads are started. Depending on the abutment of the abutment screw Material von Mises stress values are shown differently. 10Ncm T10 under the tightening torque of 294.2 MPa, P10 is 562.8 MPa, appeared to E10 is 295.8 MPa, 20Ncm tightening torque under T20 is 581.1 MPa, P20 is 1125 MPa, E20 was shown to 585.1 MPa, 30Ncm tightening torque under T30 is 918.2 MPa, P30 is 1795 MPa, E30 has appeared 925.1 MPa. Conclusion: If the abutment is used as Endoligns, it was confirmed that the abutment screw exhibits of von Mises stress value is similar to the titanium alloy abutment.

Comparisons Fitness in Implant Abutment between Gas Soldering and Laser Welding

  • Cho, Mi-Hyang;Nam, Shin-Eun
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • Objective: Osseointegration is essential process for successful implants and effects to implant in long term, therefore, passive fitness of good prosthesis is necessary. To make a good prosthesis, at first it should be done a sectioned casting and then joined method of sectioned casting body is recommended. Methods: In this study, to provide the fundamental data on stable connection method for successful implants, the author tested fitness of casting body, and compared difference between gas soldering technique and laser welding technique. Results: In fitness test of 2 abutment (test A, C), gas soldering group's fitness in the opposite part of connection was worse than laser welding group. In fitness test of 3 abutment (test B, D), gap distance was increased both in gas soldering technique and laser welding technique. Gap distance at the connecting part and the opposite part of the abutment in gas soldering technique was worse than laser welding technique and the more additional abutment, the worse gap distance in gas soldering technique. In fitness test of 3 abutment (test B, D), there's little variation in No. 2 abutment when connecting soldering process was done and there's little influence on already soldered connection part when the additional soldering connection was done. Conclusion: On weak loading condition and the part which is needed an accuracy, laser welding technique is more effective and on long-span prosthesis and frequent chewing loading part, laser welding technique is recommended first and applying additional gas soldering technique would be better for making much more successful prosthesis.

Comparative study of abutment screw loosening with or without adhesive material

  • Arshad, Mahnaz;Shirani, Gholamreza;Refoua, Sina;Yeganeh, Mohammadreza Rahimi
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.99-103
    • /
    • 2017
  • PURPOSE. The purpose of this study was to achieve more retention and stability and to delay or prevent screw loosening. MATERIALS AND METHODS. Twenty implants (Implantium 3.4 mm, Dentium, Seoul, Korea) were divided into 2 groups (n = 20). In the first group, an adhesive material was applied around the screw of the abutments (test group). In the second group, the screws are soaked in saliva (control group). All the screws were torqued under 30 N/cm, Then, the samples were gone through a cyclic fatigue loading process. After cyclic loading, we detorqued screws and calculated detorque value. RESULTS. In comparison with the control group, all the implant screws in the test group were smeared with the adhesive material, showing significant higher detorque value. CONCLUSION. There are significantly higher detorque values in the group with adhesive. It is recommended to make biocompatible adhesive to reduce screw loosening.

A STUDY ON FITNESS OF SEVERAL DOMESTIC IMPLANT FIXTURE AND ABUTMENT SCREWS (국내제작 임프란트 고정체와 지대주 유지나사의 적합도에 대한 주사전자현미경적 비교연구)

  • Park Young-Sun;Vang Mong-Sook;Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.94-109
    • /
    • 2004
  • Statement of problem : Several domestic dental implants have been developed since dental treatment being implants are increasing and popularized. However, they have not been used in domestic market like imported goods. Material and methods : This study was carried out to compare domestic and imported implants in aspect of fitness, dental implant fixture and abutment screw using scanning electron microscope. All experiments were performed under dry condition. Results : 1. Only in aspect of relation of dental implant fkxture and abutment screw, except only one group with point contact, good fitness was existed. 2. Home products must presevere in their efforts, so as excellent to fit.

Effect of connection type on the screw loosening of implant system (지대주와 고정체의 체결방법에 따른 임플란트의 풀림거동에 관한 연구)

  • Choi, Jae-Min;Chun, Heoung-Jae;Han, Chong-Hyeon;Lee, Soo-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.486-491
    • /
    • 2004
  • A comparative study on the implant screw loosening under the initial clamping force and cyclic loads was conducted. The experiments were performed to evaluate the screw loosening behavior of the internal and external implant systems. It was found that the screw loosening torques of implant systems were significantly affected by the way how the abutment and fixture were connected due to the difference in the load transfer mechanism between abutment and fixture.

  • PDF

Screw and cement retained implant prosthesis rehabilitation of mandibular edentulous patients with severely absorbed ridge (치조제가 심하게 흡수된 하악 무치악환자의 나사-시멘트 유지형 임플란트 보철 수복증례)

  • Im, Joong-Jae
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.149-156
    • /
    • 2019
  • Purpose: Prosthodontics for edentulous patients is a treatment technique using implant, which has impactful results in retention and support effects. Methods: As a retention technique, SCRP (screw and cement retained implant prosthesis) has reported in many studies as a beneficial method for both patients and curers, which can reduce errors in process of making abutment and top implant. Results: Prosthesis manufacturing, as polymerization method of hardened resin teeth with thermoplastic resin, is helpful for patients with aesthetic and financial situations regarding residual ridge and interocclusal relationship, also indicates reliable results in both retention and care. Conclusion: Using SCRP technique, we notably obtained a clinical and aesthetic outcome from five implants in anterior tooth, which are half fixable and detachable implants on screw of implant abutment by the technicians at anytime.

I-shaped incisions for papilla reconstruction in second stage implant surgery

  • Lee, Eun-Kwon;Herr, Yeek;Kwon, Young-Hyuk;Shin, Seung-Il;Lee, Dong-Yeol;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.3
    • /
    • pp.139-143
    • /
    • 2010
  • Purpose: Pink gingival esthetic especially on the anterior teeth has been an important success criterion in implant-supported restoration. Inter-implant papillae are a critical factor for implant esthetics, and various techniques for inter-implant papilla reconstruction have been introduced. The aim of this study is to suggest and evaluate a surgical technique for reconstructing inter-implant papillae. Methods: A 28-year-old man had an implant placed on the #13 and #14 area. Four months after implant placement, a second stage surgery was planned for inter-implant papilla reconstruction. At the time of the abutment connection, I-type incisions were performed on the #13i & #14i area followed by full-thickness flap elevation and connection of a healing abutment on underlying fixtures without suture. Results: Two weeks after the second stage implant surgery, soft tissue augmentation between the two implants was achieved. Conclusions: I-shaped incisions for papilla reconstruction performed during the second stage implant surgery were useful for inter-implant papilla reconstruction and showed a good esthetic result.

Effect of intra-crown cantilever on mechanical strength of internal conical joint type implant (치관 내 캔틸레버 양에 따른 내측 연결 형태 임플란트의 기계적 강도에 대한 연구)

  • Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Jeon, Young-Chan;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.5
    • /
    • pp.360-367
    • /
    • 2015
  • Purpose : The purpose of this study was to evaluate the effect of amount of cantilever in intra-crown according to implant fixture position on mechanical strength of internal conical joint type implant. Materials and Methods : Internal conical joint type implant fixture, abutment screw, abutment was connected and gold alloy prostheses were fabricated and cemented on abutment. For fatigue fracture test, the specimens were loaded to the 350 N, 2,000,000 cycle on 3, 4, 5, and 6 mm off-center of gold alloy prostheses. The fracture pattern of implant component was observed. Results : No fatigue fracture found on 3 and 4 mm group. But initial crack pattern found on 3 specimens of 4 mm group. Fatigue fracture found on all specimens of 5 mm group. But complete fracture was not observed. One specimen of 6 mm group fracture completely. Implant fixture fracture wax not observed. Conclusion : The mechanical failure of implant prostheses increased with the loading area farther from center of implant fixture. To reduce mechanical problem of internal joint type implant, surgical and prosthetic consideration is needed.

A STUDY ON SURFACE ALTERATION OF IMPLANT SCREWS AFTER FUNCTION

  • Han, Myung-Ju;Chung, Chae-Heon;Choi, Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.275-286
    • /
    • 2002
  • Statement of problem. Surface alteration of the implant screws after function may be associated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. Purpose. The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanning electron microscope). Materials and methods. In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retaining screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were performed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. Results. In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleansing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. Conclusions. These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.