• 제목/요약/키워드: Implant stability test

검색결과 109건 처리시간 0.023초

Physical stability of arginine-glycine-aspartic acid peptide coated on anodized implants after installation

  • Huh, Jung-Bo;Lee, Jeong-Yeol;Jeon, Young-Chan;Shin, Sang-Wan;Ahn, Jin-Soo;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.84-91
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the stability of arginine-glycine-aspartic acid (RGD) peptide coatings on implants by measuring the amount of peptide remaining after installation. MATERIALS AND METHODS. Fluorescent isothiocyanate (FITC)-fixed RGD peptide was coated onto anodized titanium implants (width 4 mm, length 10 mm) using a physical adsorption method (P) or a chemical grafting method (C). Solid Rigid Polyurethane Foam (SRPF) was classified as either hard bone (H) or soft bone (S) according to its density. Two pieces of artificial bone were fixed in a customized jig, and coated implants were installed at the center of the boundary between two pieces of artificial bone. The test groups were classified as: P-H, P-S, C-H, or C-S. After each installation, implants were removed from the SRPF, and the residual amounts and rates of RGD peptide in implants were measured by fluorescence spectrometry. The Kruskal-Wallis test was used for the statistical analysis (${\alpha}$=0.05). RESULTS. Peptide-coating was identified by fluorescence microscopy and XPS. Total coating amount was higher for physical adsorption than chemical grafting. The residual rate of peptide was significantly larger in the P-S group than in the other three groups (P<.05). CONCLUSION. The result of this study suggests that coating doses depend on coating method. Residual amounts of RGD peptide were greater for the physical adsorption method than the chemical grafting method.

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구 (Biological stability of Zirconia/Alumina composite ceramic Implant abutment)

  • 배규현;한증석;김태일;설양조;이용무;구영;조기영;정종평;한수부;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.

Influence of wound closure on volume stability with the application of different GBR materials: an in vitro cone-beam computed tomographic study

  • Naenni, Nadja;Berner, Tanja;Waller, Tobias;Huesler, Juerg;Hammerle, Christoph Hans Franz;Thoma, Daniel Stefan
    • Journal of Periodontal and Implant Science
    • /
    • 제49권1호
    • /
    • pp.14-24
    • /
    • 2019
  • Purpose: To assess the influence of using different combinations of guided bone regeneration (GBR) materials on volume changes after wound closure at peri-implant dehiscence defects. Methods: In 5 pig mandibles, standardized bone defects were created and implants were centrally placed. The defects were augmented using different combinations of GBR materials: xenogeneic granulate and collagen membrane (group 1, n=10), xenogeneic granulate and alloplastic membrane (group 2, n=10), alloplastic granulates and alloplastic membrane (group 3, n=10). The horizontal thickness was assessed using cone-beam computed tomography before and after suturing. Measurements were performed at the implant shoulder (HT0) and at 1 mm (HT1) and 2mm (HT2) below. The data were statistically analysed using the Wilcoxon signed-rank test to evaluate within-group differences. Bonferroni correction was applied when calculating statistical significance between the groups. Results: The mean horizontal thickness before suturing was $2.55{\pm}0.53mm$ (group 1), $1.94{\pm}0.56mm$ (group 2), and $2.49{\pm}0.73mm$ (group 3). Post-suturing, the values were $1.47{\pm}0.31mm$ (group 1), $1.77{\pm}0.27mm$ (group 2), and $2.00{\pm}0.48mm$ (group 3). All groups demonstrated a loss of horizontal dimension. Intragroup changes exhibited significant differences in group 1 (P<0.001) and group 3 (P<0.01). Intergroup comparisons revealed statistically significant differences of the relative changes between groups 1 and 2 (P=0.033) and groups 1 and 3 (P=0.015). Conclusions: Volume change after wound closure was minimized by using an alloplastic membrane. The stability of the augmented horizontal thickness was most ensured by using this type of membrane irrespective of the bone substitute material used for membrane support.

치과보철용 자석재료의 전기화학적 안정성 개선효과 (IMPROVEMENT EFFECTS OF ELECTROCHEMICAL STABILITY OF MAGNETIC MATERIALS FOR PROSTHETIC DENTISTRY)

  • 곽종하;오상호;최한철;정재헌
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.628-641
    • /
    • 2006
  • Statement of problem: Dental magnetic materials have been applied to removable prosthetic appliances, maxillofacial prostheses, obturator and dental implant but they still have some problems such as low corrosion resistance in oral environments. Purpose: To increase the corrosion resistance of dental magnetic materials, surfaces of Sm-Co and Nd-Fe-B based magnetic materials were plated with TiN and sealed with stainless steels. Materials and methods : Surfaces of Sm-Co and Nd-Fe-B based magnetic materials were plated with TiN and sealed with stainless steels, and then three kinds of electrochemical corrosion test were performed in 0.9% NaCl solution; potentiodynamic, potentiostatic, and electrochemical impedance test. From this study, corrosion behavior, amount of elements released, mean average surface roughness values, the changing of retention force, and magnetic force values were measured comparing with control group of non-coated magnetic materials. Results: The values of surface roughness of TiN coated Sm-Co and TiN coated Nd-Fe-B based magnetic materials were lower than those of non coated Sm-Co and Nd-Fe-B alloy. From results of potentiodynamic test, the passive current density of TiN coated Sm-Co alloy were smaller than those of TiN coated Nd-Fe-B alloy and non coated alloys in 0.9% NaCl solution. From results of potentiostatic and electrochemical impedance test, the surface stability of the TiN coated Sm-Co alloy was more drastically increased than that of the TiN coated Nd-Fe-B alloy and non-coated alloy. The retention and magnetic force after and before corrosion test did not change in the case of TiN coated magnetic alloy sealed with stainless steel. Conclusion: It is considered that the corrosion problem and improvement for surface stability of dental magnetic materials could be solved by ion plating with TiN on the surface of dental magnetic materials and by sealing with stainless steels.

$OPB-K^{(R)}$가 임플랜트의 골유착 및 안정성에 미치는 영향에 관한 연구 (The Effect of $OPB-K^{(R)}$ on the Osseointegration and Stability of Implant)

  • 강성진;조인호;신수연
    • 대한치과보철학회지
    • /
    • 제46권1호
    • /
    • pp.31-41
    • /
    • 2008
  • 현대 치의학에서 임플랜트가 상실치 수복에 가장 효과적인 대안으로 여겨지면서, 임플랜트의 골유착을 보다 쉽게 얻기 위한 여러 연구들이 진행되고 있다. 이에 임플랜트의 형태 및 표면 처리법 등에 많은 진보가 이루어졌으며, 최근에는 임플랜트 주위골의 치유율을 높이고 골밀도를 증가시키는 약제의 개발도 보고되어, Pleurotus eryngii Quel와 Eleu- therococcus senticosus가 주성분인 $OPB-K^{(R)}$는 조골세포의 증식과 활성을 자극하고 파골세포의 생성과 활성을 억제하는 것으로 알려져 있다. 이에 본 연구에서는 특수 제작한 임플랜트를, 골다공증 유도를 위해 난소절제술을 시행한 백서 36 마리의 경골에 식립한 후 $OPB-K^{(R)}$ (Post-$Plant^{TM}$ Calcium, Oscotech, Korea)를 투여한 군을 실험군, 투여하지 않은 군을 대조군으로 2주, 4주, 6주에 $Periotest^{(R)}$, 골밀도 측정 및 조직학적 검사 등을 이용하여 골유착 정도를 비교분석하여 다음과 같은 결론을 얻었다. 1. $Periotest^{(R)}$ 측정 결과 시간이 경과함에 따라 실험군, 대조군 모두 수치가 낮아지며, 2주에서는 각 군간에 유의한 차이가 없었으나, 4 주, 6주에서는 각 군간에 유의한 차이가 관찰되었다(p<0.05). 2. 골밀도 측정결과, 난소절제에 따른 결과로 시간이 경과함에 따라 실험군, 대조군 모두 골밀도가 감소하는 경향을 나타내었으며, 2주와 4주에서는 각 군간에 유의한 차이가 없었으나, 6주에서는 각 군간에 유의한 차이가 관찰되었다(p<0.05). 3. 조직학적 검사결과 시간이 경과할수록 실험군이 대조군에 비해 골유착면에서 더 나은 소견을 보였다. 이상의 결과로 볼 때 $OPB-K^{(R)}$를 투여한 군이 대조군에 비해 임플랜트 주위 골밀도와 임플랜트 안정성면에서 더 나은 결과를 보였고 통계적으로 유의한 차이가 있었다. 임상적으로 임플랜트 식립 후 $OPB-K^{(R)}$를 환자에게 장기간 투여하는 것이 성공적인 임플랜트 시술에 좋으리라 사료된다.

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

Cervical spine reconstruction after total vertebrectomy using customized three-dimensional-printed implants in dogs

  • Ji-Won Jeon;Kyu-Won Kang;Woo-Keyoung Kim;Sook Yang;Byung-Jae Kang
    • Journal of Veterinary Science
    • /
    • 제25권1호
    • /
    • pp.2.1-2.14
    • /
    • 2024
  • Background: Sufficient surgical resection is necessary for effective tumor control, but is usually limited for vertebral tumors, especially in the cervical spine in small animal neurosurgery. Objective: To evaluate the primary stability and safety of customized three-dimensional (3D)-printed implants for cervical spine reconstruction after total vertebrectomy. Methods: Customized guides and implants were designed based on computed tomography (CT) imaging of five beagle cadavers and were 3D-printed. They were used to reconstruct C5 after total vertebrectomy. Postoperative CT images were obtained to evaluate the safety and accuracy of screw positioning. After harvesting 10 vertebral specimens (C3-C7) from intact (group A) and implanted spines (group B), implant stability was analyzed using a 4-point bending test comparing with groups A and C (reconstituted with plate and pins/polymethylmethacrylate after testing in Group A). Results: All customized implants were applied without gross neurovascular damage. In addition, 90% of the screws were in a safe area, with 7.5% in grade 1 (< 1.3 mm) and 2.5% in grade 2 (> 1.3 mm). The mean entry point and angular deviations were 0.81 ± 0.43 mm and 6.50 ± 5.11°, respectively. Groups B and C significantly decreased the range of motion (ROM) in C3-C7 compared with intact spines (p = 0.033, and 0.018). Both groups reduced overall ROM and neutral zone in C4-C6, but only group B showed significance (p = 0.005, and 0.027). Conclusion: Customized 3D-printed implants could safely and accurately replace a cervical vertebra in dog cadavers while providing primary stability.

성견의 Implant 주위에 $GUIDOR^{(R)}$ BARRIER MEMBRANE 사용후 골신생에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF $GUIDOR^{(R)}$ BARRIER MEMBRANE ABOUT BONE PROMOTION AROUND DENTAL IMPLANTS PLACED INTO EXTRACTION SOCKET IN DOGS)

  • 양명철;진우정;신효근;김오환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권1호
    • /
    • pp.135-143
    • /
    • 1996
  • 이 연구의 목적은 성견의 발치와에 식립된 implants에 새로운 골 형성을 유도할 목적으로 사용한 흡수성막의 골유도재생술을 평가하고자 하였다. 성견의 제 3소구치를 발거하고 cylindrial HA-coated implants를 식립하였다. 실험군에는 흡수성막인 $GUIDOR^{(R)}$ 를 덮어 보호를 하고, 대조군은 막으로 보호하지 않았다. 성견은 1, 2, 4개월에 차례로 희생하였으며, 치유과정 및 골형성 정도의 평가를 위해 임상적, 방사선학적, 그리고 조직학적 관찰을 통한 다음과 같은 결론을 얻었다. 1. 치유리간 동안에 실험군의 흡수성막의 안정성과 조직의 만족할 만한 치유능력을 볼 수 있었다. 2. 술후 4개월 정도에서 막이 완전한 흡수를 볼 수 있었다. 3. 미숙골이 정상적인 충판의 성숙골로 바뀌는데 약 4개월의 시간이 필요하였다. 4. 대조군에 비하여 실험군에서 더 많은 골형성을 관찰할 수 있었다. 5. 흡수성막이 implant 매식에 유용하게 이용될 수 있으리라 평가한다.

  • PDF

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.