• Title/Summary/Keyword: Implant placement

Search Result 644, Processing Time 0.023 seconds

THE STUDY ON THE BONE RESORPTION RATE AFTER VERTICAL ALVEOLAR RIDGE AUGMENTATION (수직적 치조제 증강술후 발생하는 골흡수량에 관한 연구)

  • Jeon, Ha-Ryong;Kim, Jong-Won;Kwon, Ho-Beom;Lee, Dong-Hwan;Hong, Jong-Rak;Kim, Chang-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.3
    • /
    • pp.230-234
    • /
    • 2006
  • Purpose: This study presents radiographic and laboratory analysis and comparison of bone resorption rate of grafted endochondral bone and intramembranous bone on the aspect of height and volumetric change. Patients and Methods: 18 partially edentulous patients who needed alveolar ridge augmentation for implant placement during the years 2002 to 2004 were selected for this study. Group A consisted of 5 males & 3 females who were treated with intraoral(intramembranous) bone and Group B consisted of 8 males & 2 females who were treated with iliac(endochondral) bone. Non-standard periapical X-ray was taken at day 1, 2 month, 4 months, 8 months after the surgery. Resorption rate of grafted bone were measured on these X-rays and compared. Also we calculated volume of grafted bone with models which was fabricated at 1.5 months, 6 months. Results: There was bone resorption in both groups. Group B showed more bone resorption than Group A. In Group A, the resorption rate according to the radiographic measurements was 9.81 %, and resorption rate according to volumetric measurement was 16.5 %. In group B, the resorption rate according to the radiographic measurements was 15.9 %, and resorption rate according to volumetric measurement was 30.6 %. Significant difference is on radiographic resorption of post-op 2, 4, 8 months on two groups (P < 0.05). Also significant difference is on volume resorption on two groups (P < 0.05). Conclusion: We found that more bone resorption occurred with iliac(endochondral) bone and when we use intraoral bone, that bone can maintain their vitality for alveolar ridge augmentation.

Clinical Experiences and Usefulness of Cervical Posterior Stabilization with Polyaxial Screw-Rod System

  • Hwang, In-Chang;Kang, Dong-Ho;Han, Jong-Woo;Park, In-Sung;Lee, Chul-Hee;Park, Sun-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.311-316
    • /
    • 2007
  • Objective : The objective of this study is to investigate the safety, surgical efficacy, and advantages of a polyaxial screw-rod system for posterior occipitocervicothoracic arthrodesis. Methods : Charts and radiographs of 32 patients who underwent posterior cervical fixation between October 2004 and February 2006 were retrospectively reviewed. Posterior cervical polyaxial screw-rod fixation was applied on the cervical spine and/or upper thoracic spine. The surgical indication was fracture or dislocation in 18, C1-2 ligamentous injury with trauma in 5, atlantoaxial instability by rheumatoid arthritis (RA) or diffuse idiopathic skeletal hyperostosis (DISH) in 4, cervical spondylosis with myelopathy in 4, and spinal metastatic tumor in 1. The patients were followed up and evaluated based on their clinical status and radiographs at 1, 3, 6 months and 1 year after surgery. Results : A total of 189 screws were implanted in 32 patients. Fixation was carried out over an average of 3.3 spinal segment (range, 2 to 7). The mean follow-up interval was 20.2 months. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-7 lateral masses, as well as the lower cervical and upper thoracic pedicles. Satisfactory bony fusion and reduction were achieved and confirmed in postoperative flexion-extension lateral radiographs and computed tomography (CT) scans in all cases. Revision surgery was required in two cases due to deep wound infection. One case needed a skin graft due to necrotic change. There was one case of kyphotic change due to adjacent segmental degeneration. There were no other complications, such as cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, or implant failure, and there were no cases of postoperative radiculopathy due to foraminal stenosis. Conclusion : Posterior cervical stabilization with a polyaxial screw-rod system is a safe and reliable technique that appears to offer several advantages over existing methods. Further biomechanical testings and clinical experiences are needed in order to determine the true benefits of this procedure.

Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants (교점용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교)

  • Yun, Soon-Dong;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.95-104
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the effect of length and shape of cutting flute on mechanical properties of orthodontic mini-implants. Methods: Three types of mini-implants with different flute patterns (Type A with 2.6 mm long flute, Type B with 3.9 mm long and straight flute, Type C with 3.9 mm long and helical flute) were inserted into the biomechanical test blocks (Sawbones Inc., USA) with 2 mm and 4 mm cortical bone thicknesses to test insertion and removal torque. Results: In 4 mm cortical bone thickness, Type C mini-implants showed highest maximum insertion torque, then Type A and Type B in order. Type C also showed shortest total insertion time and highest maximum removal torque, but Type A and B didn't showed statistically significant difference in insertion time and removal torque. In 2 mm cortical bone thickness, there were no significant difference in total insertion time and maximum removal torque in three types of mini-implants, but maximum insertion torque of Type A was higher than two other Types of mini-implants. Conclusions: Consideration about length and shape of cutting flute of mini-implant is also required when the placement site has thick cortical bone.

THE ERUPTION GUIDANCE OF IMPACTED MAXILLARY ANTERIOR TEETH (맹출장애를 보이는 상악 전치의 맹출유도)

  • Sim, Jeung-Ho;Eum, Jong-Hyeok;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.34-40
    • /
    • 2004
  • Unerupted maxillary anterior teeth is not a common case, However it may present practitioners with management problem. The cause of impaction is considered to be multifactorial, and local cause is the most common. These impacted teeth require surgical intervention, removal, transplantation, or surgical exposure, with or without orthodontic traction to align the malpositioned tooth. The preferred option is surgical exposure and orthodontic correction. Surgical intervention and orthodontic correction should not be delayed to avoid unnecessary difficulties in aligning the tooth in the arch. Surgical exposure should be performed with the intent of providing sufficient attached gingiva rather than simply uncovering the crown, which results in only alveolar mucosal attachment. Attached gingiva is essential to secure the gingival tissues to the adjacent teeth at the dentogingival junction. Thus preventing loss of periodontal tissues as a result of the pull of the surrounding soft tissues and facial muscles. Labially impacted maxillary anterior teeth uncovered with an apically positioned flap technique have more un- esthetic sequelae than those uncovered with a closed-eruption technique. In the case of severly displaced impacted teeth, autotransplantation ensures preservation of the alveolar bone and will facilitate future placement of an osseointegrated implant once growth has ceased or if ankylosis/resorption of the transplant occurs.

  • PDF

A Histo-Pathological Study of Effect on Bone Regeneration with Fibrin Adhesive (이종골 이식시 Fibrin adhesive의 사용이 골 재생에 미치는 영향에 관한 조직병리학적 연구)

  • Ko, Young-Woo;Lim, Sung-Bin;Chung, Chin-Hyung;Lee, Chong-Heon
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.1
    • /
    • pp.91-102
    • /
    • 2003
  • Several effective treatment methods and materials have been developed for the treatment of furcation involvement. Currently, the combination of guided tissue regeneration (GTR) and bone grafts is the most commonly prescribed method of treating furcation involved defects. But because these cases often present with poor accessibility, placement of the membrane may be difficult and consequently, clinically impractical. In this study, the alveolar bone healing patterns of adult beagle dogs presenting with alveolar bone destruction treated by one of two methods - treatment using solely bone allografts (BBP(R)), or treatment using bone allografts (BBP(R)) stabilized by a fibrin adhesive - were comp ared. The effects of the fibrin adhesive on the initial stabilization of the newly formed bone, subsequent regeneration of bone, and the feasibility of the clinical application of the fibrin adhesive were analyzed. The results of the study were as follows: 1. Clinical signs of inflammation at the 4-8 week interval were not observed: but signs of mild inflammation were histologically observed at the 4-week interval. 2. Allografts stabilized by fibrin adhesive showed good bone formation, whereas defects treated with only the allograft material showed incomplete alveolar bone regeneration. 3. Allografts stabilized by fibrin adhesive showed a decrease in the amount old bone with a concurrent increase in the formation of new lamellar bone four weeks post-op, whereas defects treated with only the allograft material showed no new lamellar bone formation at the same interval. 4. In detects treated with only the allograft material, the defective area was filled with connective tissue 8-weeks post-op, whereas fibrin adhesive stabilized allografts showed viable connections between the original bone and the newly formed bone, in addition to neovascularization 8-weeks post-op. The results of this study show that concurrent use of fibrin adhesive materials can stabilize the allograft material and aid in new bone formation Although the stability of fibrin adhesives fall short of the results achievable by GTR membranes, in cases presenting with poor accessibility that contraindicate the use of membranes, fibrin adhesive materials provide a viable and effective alternative to graft stabilization and new bone formation.

The Measurement of Vertical Length from the Root Tip of Maxillary Anterior Teeth to Nasal Floor, When Maxillary Anterior Implants Placed (상악전치부 임플란트 식립 시 상악전치부 치근첨에서 비강저까지 치조골의 수직적 길이 측정)

  • Jang, Hae-Man;Kim, Jin-Wook;Kwon, Tae-Geon;Jang, Hyun-Joong;Kim, Chin-Soo;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.326-331
    • /
    • 2012
  • Purpose: Length measurement from maxillary anterior teeth root tip to nasal floor is incorrect in panoramic radiography. Comparison of cone beam computed tomography (CBCT) and panoramic radiography should be helpful in determining the vertical length. Methods: Sixty nine patients were taken CBCT and panoramic radiography of the maxillary anterior. First measurement is length of parallel lines from the central incisor and lateral incisor root tip to nasal floor on CBCT. Second measurement is length of perpendicular lines from the central incisor and lateral incisor root tip to nasal floor on CBCT. Third measurement is length from the central incisor and lateral incisor root tip to nasal floor on panoramic radiographys. Results: In the first measurement of the maxillary central incisors, an average of $11.36{\pm}2.49$ mm in males and $10.49{\pm}2.17$ mm in females. In the second measurement of the maxillary central incisors, $10.41{\pm}2.42$ mm in males and $9.18{\pm}2.08$ mm in females. In the third measurement of the maxillary central incisors, $10.71{\pm}2.20$ mm in males and $9.27{\pm}2.10$ mm in females. In the first measurement of the maxillary lateral incisors, an average of $13.40{\pm}2.04$ mm in males and $11.96{\pm}2.20$ mm in females. In the second measurement of the maxillary lateral incisors, $11.25{\pm}1.82$ mm in males and $10.06{\pm}1.68$ mm in females. In the third measurement of the maxillary lateral incisors, $11.47{\pm}2.01$ mm in males and $10.13{\pm}1.70$ mm in females. Conclusion: The vertical length from root tip to nasal floor was longer in male than female (P>0.05). First measurement was longer than third measurement (P<0.05). This is the actual placement of the implant site measured on the vertical length than the length of the panorama means that there are a few more free. The first measurement was longer than 114% over the third measurement.

Cortical bone strain during the placement of orthodontic microimplant studied by 3D finite element analysis (3차원 유한요소법을 이용한 교정용 마이크로임플란트 식립 시의 피질골 스트레인 해석)

  • Nam, Ok-Hyun;Yu, Won-Jae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.228-239
    • /
    • 2008
  • Objective: The aim of this study was to evaluate the strain induced in the cortical bone surrounding an orthodontic microimplant during insertion. Methods: A 3D finite element method was used to model the insertion of a microimplant (AbsoAnchor SH1312-7, Dentos Co., Daegu, Korea) Into 1 mm thick cortical bone with a pre-drilled hole of 0.9 mm in diameter. A total of 1,800 analysis steps was used to simulate the 10 turns and 5 mm advancement of the microimplant. A series of remesh in the cortical bone was allowed to accommodate the change in the geometry accompanied by the implant insertion. Results: Bone strains of well higher than 4,000 microstrain, the reported upper limit for normal bone remodeling, was observed in the bone along the whole length of the microimplant. At the bone in the vicinity of the screw tip, strains of higher than 100% was recorded. The insertion torque was calculated at approximately 1.2 Ncm which was slightly lower than those measured from the animal experiment using rabbit tibias. Conclusions: The insertion process of a microimplant was successfully simulated using the 3D finite element method which showed that bone strains from a microimplant insertion might have a negative impact on physiological remodeling of bone.

Bone Added Osteotome Sinus Floor Elevation with Simultaneous Placement of Branemark Ti-Unite and ITI SLA implants (Osteotome 상악동 거상술과 동시에 식립한 $Br{\aa}nemark$ Ti-Unite 과 ITI SLA임프란트의 비교 연구)

  • Kang, Nam-Won;Jung, Ui-Won;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.609-621
    • /
    • 2005
  • 1. 목적 Osteotome 상악동거상술(Bone Added Odteotome Sinus Floor Elevation ; 이하 BAOSFE) 과 동시에 식립한 임프란트($Br{\aa}nemark$, ITI)의 예상 생존율에 대해 현재까지 정확히 알려진 바는 없었으며, $Br{\aa}nemark$ Ti-Unite 과 ITI SLA 임프란트의 표면에 대한 비교 연구 또한없었다. 이번 연구는 BAOSFE 술식과 동시에 식립한 $Br{\aa}nemark$ Ti-Unite 과 ITI SLA 임프란트의 임상 결과를 비교, 평가하고 초기 치유기간 동안의 이식골 높이의 변화를 방사선학적으로 관찰하여 두 가지 임프란트 시스템을 비교해 보고자 한다. 2. 방법 위축된 상악 구치부를 갖는 22명의 환자를 대상으로, BAOSFE술식과동시에 $Br{\aa}nemark$ Ti-Unite(11명, 13 임프란트)임프란트와 ITI SLA(11명, 18 임프란트)임프란트를 식립하였다. 수술 전, 임프란트 식립 직후, 술후 6개월의 파노라마 방사선 사진을 촬영하여 비교 및 평가에 사용하였다. 각 임프란트 시스템의 생존율을 측정하고, 술전 상악동저 높이와 식립된 임프란트 길이를 참고하여 이식골 높이의 방사선학적 변화를 평가하였다. 3. 결과 평균12개월의 추적기간 결과, $Br{\aa}nemark$ Ti-Unite 임프란트의 생존율은 100%(13/13 임프란트)이었으며, ITI SLA 임프란트의 생존율은 94.4%(17/18 임프란트)이었다. 초기 치유 기간인 6개월 동안 평균 이식골 높이의 감소는 $Br{\aa}nemark$ Ti-Unite 임프란트에서 0.67mm(10.73%), ITI SLA 임프란트에서는 0.55mm(8.18%)로 나타났다. 두 가지 임프란트 시스템 간의 유의성 있는 차이는 보이지 않았다. 4. 고찰 BAOSFE 술식과 동시식립한 $Br{\aa}nemark$ Ti-Unite 과 ITl SLA 임프란트는 위축된 상악 구치부를 갖는 환자에서 효과적인 치료방법이 될 수 있으며, 임프란트 표면에 따른 이식골의 치유 반응은 두 가지 임프란트 시스템에서 유사한 양상으로 일어남을 알 수 있었다.

Stabilization of Short Juxta-articular Fractures Using a Circular External Skeletal Fixator System in Dogs (개에서 원형외고정장치를 이용한 관절주위 골절의 안정화)

  • Cheong, Hye-Yeon;Kim, Joo-Ho;Cha, Jae-Gwan;Seol, Jae-Won;Kim, Min-Su;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.523-526
    • /
    • 2014
  • Three dogs were admitted for repair of bone fracture. Case 1 (Maltese, 1.8 kg, intact female, 5-month-old) and case 2 (poodle, 3.0 kg, intact female, 6-month-old) had non-weight bearing lameness in the left pelvic limb, and case 3 (mixed, 3.3 kg, intact female, age unknown) had non-weight-bearing lameness in the left thoracic limb. On orthopedic examination, there was pain, crepitus, palpable instability and substantial soft tissue swelling on the affected side. No neurological deficits were identified. Radiographs revealed left proximal metaphyseal tibial and fibular fractures in cases 1 and 2, and left proximal metaphyseal radial and ulnar fractures in case 3. All cases had closed long-bone fractures with short juxta-articular fracture segments. Under fluoroscopic guidance, proper placement of the ring fixation elements was confirmed during surgery. Two or three rings were used to stabilize fractures with traditional circular external skeletal fixators (CESF). Postoperative radiographs showed acceptable alignment and apposition of the previously identified fracture. Time to radiographic union ranged from 5 to 14 weeks and there were no signs of implant failure or pin tract infection. Functional outcomes were excellent in all cases. CESF can be successfully used to reduce short juxta-articular fractures in which bone plates or external skeletal fixation cannot be applied.

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.