• Title/Summary/Keyword: Implant fixed prostheses

Search Result 140, Processing Time 0.029 seconds

Fabrication of definitive complete-arch implant-supported fixed prosthesis in upper and lower completely edentulous patient using temporary prosthesis scan: a case report (상하악 완전 무치악 환자에서 임시 보철물 스캔을 이용한 일체형 임플란트 지지 고정성 보철물 수복 증례)

  • Seung-Mi Jeong;Hyun-Lak Son;Kang-Duck Choi;Byung-Ho Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.3
    • /
    • pp.243-252
    • /
    • 2024
  • When fabricating definitive implant-supported fixed prostheses in upper and lower completely edentulous patients, it is crucial to get information about the vertical dimension, jaw relationship, implants, abutments and gingival contour. In this case, temporary prostheses were used to take the information. The temporary prosthesis was scanned outside of the mouth so that it increased the efficiency of scanning it. During the scan of the prosthesis, a scan zig which connected both posterior parts of the prosthesis was used to minimize the scan errors. We report this case because we obtained satisfactory functional and esthetic results by using the digital technology.

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

A prospective clinical of lithium disilicate pressed zirconia and monolithic zirconia in posterior implant-supported prostheses: A 24-month follow-up (리튬 디실리케이트-지르코니아 이중도재관과 단일구조 지르코니아로 제작된 구치부 고정성 임플란트 지지 보철물의 전향적 임상연구: 24개월 추적관찰)

  • Roh, Kyoung-Woo;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, So-Hyoun;Yang, Dong-Seok;Bae, Eun-Bin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.134-141
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the clinical outcomes of lithium disilicate ceramic pressed zirconia prostheses and monolithic zirconia prostheses and to investigate the complications after two years of follow-up in posterior edentulous site. Materials and methods: A total 17 patients (male: 12, female: 5) were treated with 60 posterior fixed implant-supported prostheses (LP. lithium disilicate ceramic pressed zirconia prostheses: n = 30, MZ. monolithic zirconia prostheses: n = 30). After 24-month, clinical examination of Implant survival rate, marginal bone resorption, probing depth, plaque index, bleeding index, calculus and complications were evaluated. Results: There were no failed implants and all implants were normal in function without mobility. Marginal bone resorption was lower in LP group than MZ group at 12-month (P < .05), and 12-month probing depth and calculus deposit in LP group were significantly higher than MZ group (P < .05). Most common complications in MZ were marginal bone resorptions more than 1.5.mm and 2 chipping occurred in LP group. Conclusion: Within the limitations of the present study, lithium disilicate ceramic pressed zirconia is considered as a predictable treatment option as much as monolithic zirconia in posterior fixed implant-supported prostheses.

Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques

  • Zhou, Ying;Li, Yong;Ma, Xiao;Huang, Yiqing;Wang, Jiawei
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.124-129
    • /
    • 2017
  • PURPOSE. This study evaluated the effect of span length on the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques. MATERIALS AND METHODS. Models with two solid abutment analogs at different inter-abutment distances were digitized using a laboratory scanner. Frameworks of two-, three-, and four-unit fixed prostheses were designed by a computer. Six dots with a diameter of 0.2 mm were preset on the surface of each framework. A total of 54 implant-supported cobalt chromium frameworks were fabricated by milling, selective laser melting (SLM), and cast techniques. The frameworks were scanned and exported as Stereolithography files. Distances between two dots in X, Y, and Z coordinates were measured in both the designed and fabricated frameworks. Marginal gaps between the framework and the abutments were also evaluated by impression replica method. RESULTS. In terms of distance measurement, significant differences were found between three- and four-unit frameworks, as well as between two- and four-unit frameworks prepared by milling technique (P<.05). Significant differences were also noted between two- and three-unit frameworks, as well as between two- and four-unit frameworks prepared by cast technique (P<.05). The milling technique presented smaller differences than the SLM technique, and the SLM technique showed smaller differences than the cast technique at any unit prostheses (P<.05). Evaluation with the impression replica method indicated significant differences among the span lengths for any fabrication method (P<.05), as well as among the fabrication methods at any unit prostheses (P<.05). CONCLUSION. The adaptation of implant-supported cobalt chromium frameworks was affected by the span length and fabrication method.

Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses (3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석)

  • Kim, Sang-Beom;Lee, Du-Hyeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.321-327
    • /
    • 2020
  • Purpose: The purpose of this study was to measure and compare the strain value exerted on the cervical area using different screw tightening protocols in implant-supported, screw-retained 3-unit prostheses. Materials and methods: Strain gauges were attached to four implants: two external and two internal. Thereafter, two study model were designed each type using acrylic resin. CAD-CAM was used to design hex and nonhex abutments for each group (EH, ENH, IH, and INH group) and Screw-cement-retained prostheses were also designed using a nonprecious base metal. Abutment was fixed with 10 Ncm torque, and the prosthesis was cemented. Screws were fixed with 30 Ncm torque using different three protocols. After 5 min, the strain gauge level was measured, and group analysis was performed (α=.05). Results: External group showed significantly lower strain values than internal group and the EH group showed significantly lower strain values than the ENH group (P<.05). There was no difference in strain value based on the types of screw tightening protocols in same group (P>.05). The IH group exhibited significantly higher strain values than the INH group and the IH group showed a significant difference in strain values based on the types of screw tightening protocols used (P<.05). Conclusion: There was no significant effect on the external type in the implant-supported, screw-retained prostheses. However, strain values were high in the internal type, and the types of screw tightening protocol significantly affected these implants.

Application and consideration of digital technology for removable complete denture (총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰)

  • Lee, Jung-Jin;Song, Kwang-Yeob;Park, Ju-Mi
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.534-543
    • /
    • 2019
  • Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.

  • PDF

Rehabilitation using short implants in the mandibular fully edentulous patient with severe alveolar bone loss: a case report (치조골 흡수가 심한 하악 완전 무치악 환자에서 짧은 임플란트를 이용한 고정성 보철 수복 증례)

  • Hwang, Hee-Sun;Lee, Ki-Young;Kim, Yu-Lee
    • The Journal of the Korean dental association
    • /
    • v.54 no.9
    • /
    • pp.692-702
    • /
    • 2016
  • A short dental implant is considered as possible solution in difficult clinical situations for the placement of a regular length implant. Using a short implant avoiding more invasive surgical procedures simplifies the treatment plan and shortenes the duration of treatment. In this case, 71-year-old female came up with discomfort from her old mandibular denture. As she had fully edentulous mandible and got a negative feedback from removable denture, implant-supported fixed prosthesis was planned. Six short implants were placed on her mandible with severe alveolar bone loss. After 1 year follow up period, implants were well retained with any other abnormal findings. The patient was satisfied with her prostheses and satisfactory outcomes were attained in terms of both esthetic and functional clinical results.

  • PDF

Burnishing effect on marginal misfit of implant-supported screw-and-cement retained prostheses: A case report (임플란트 지지 나사-시멘트 유지형 보철물에서 보철물-지대주 제거 후 변연부 연마의 효과: 증례보고)

  • Kim, Mijoo;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.239-243
    • /
    • 2020
  • When the marginal fit of fixed dental prosthesis decreases, biological and technical complications, such as plaque accumulation, periodontal disease, hypersensitivity, components fracture, cement loss, can happen. The complications affect the long-term success and survival of prostheses. This case report describes a clinical procedure to minimize the marginal gap of implant-supported screw-and-cement retained prosthesis by removing prosthesis-abutment complex and burnishing the interface area. The marginal gap was measured before and after the burnishing using a stereomicroscope and compared. This technique improves the marginal fit, thereby contributing the longevity of the prosthesis.

Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system (구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례)

  • Jung, Jiwon;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.44-54
    • /
    • 2022
  • Without proper treatment on the multiple tooth missing area, the lack of posterior support and the supra-eruption of the teeth cause many severe complications of occlusion, vertical dimension and masticatory function. This report is a case of full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion due to missing teeth area left untreated for a long time. The patient who is 68-year old male patient had some teeth fallen out while removing his old maxillary denture and was complaining about pain in the region of anterior teeth due to traumatic contact. The vertical dimension was corrected by 4 mm from the top cervical point of the canine through various evaluations and the edentulous area was treated with the implant fixed prostheses through computer guided implant surgery based on the diagnosis and treatment plan for definitive prostheses supported by computed tomography (CT) data analysis and CAD-CAM (Computer-aided design/computer-aided manufacturing) technique. After full mouth rehabilitation, the patient was very satisfied with remarkable improvements in mastication, function, and aesthetics.

Full mouth implant-supported fixed prosthesis restoration of an edentulous maxillary patient using computer-guided implant surgery (Computer-guided implant surgery를 활용한 상악 무치악 환자의 전악 임플란트고정성 보철물 수복 증례)

  • Min-tae Lee;Sung Yong Kim;Sun-Young Yim;Yong-Sang Lee;Keun-Woo Lee;Seong-A Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.63-72
    • /
    • 2023
  • When oral restoration is performed with a full mouth implant-supported fixed restoration in an edentulous patient, it is very important to determine the shape and position of the definitive prosthesis in consideration of the anatomical state and the relationship with the antagonist, and the process of placing multiple implants in the planned direction and angle is very important. In this case, implants were ideally planned based on an upper prosthesis through a computer-guided surgical procedure for an edentulous maxillary patient who visited due to discomfort in the existing denture. Through this, we would like to report this because we obtained satisfactory functional and esthetic results for both the patient and the operator with the treatment of oral restoration by manufacturing a fixed prosthesis for maxillary and full jaw implants.