DOI QR코드

DOI QR Code

리튬 디실리케이트-지르코니아 이중도재관과 단일구조 지르코니아로 제작된 구치부 고정성 임플란트 지지 보철물의 전향적 임상연구: 24개월 추적관찰

A prospective clinical of lithium disilicate pressed zirconia and monolithic zirconia in posterior implant-supported prostheses: A 24-month follow-up

  • 노경우 (부산대학교 치과대학 치과보철학교실) ;
  • 전영찬 (부산대학교 치과대학 치과보철학교실) ;
  • 정창모 (부산대학교 치과대학 치과보철학교실) ;
  • 윤미정 (부산대학교 치과대학 치과보철학교실) ;
  • 허중보 (부산대학교 치과대학 치과보철학교실) ;
  • 이소현 (부산대학교 치과대학 치과보철학교실) ;
  • 양동석 (부산대학교 치과대학 치과보철학교실) ;
  • 배은빈 (부산대학교 치과대학 치과보철학교실)
  • Roh, Kyoung-Woo (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University) ;
  • Jeon, Young-Chan (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University) ;
  • Jeong, Chang-Mo (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University) ;
  • Yun, Mi-Jung (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University) ;
  • Huh, Jung-Bo (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University) ;
  • Lee, So-Hyoun (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University) ;
  • Yang, Dong-Seok (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University) ;
  • Bae, Eun-Bin (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University)
  • 투고 : 2019.02.14
  • 심사 : 2019.03.21
  • 발행 : 2019.04.30

초록

목적: 본 연구에서는 리튬 디실리케이트-지르코니아 이중도재관과 단일구조 지르코니아로 제작된 구치부 고정성 임플란트 지지 보철물의 2년간의 임상적 결과를 비교하고자 하였다. 대상 및 방법: 2015년에서 2018년 사이 부산대학교 치과병원에 내원하여 치료받은 총 17명의 환자(남성: 12, 여성: 5)를 대상으로 60개의 구치부 고정성 임플란트 지지 보철물을 제작하였다(LP. Lithium disilicate pressed zirconia prostheses: n = 30, MZ. Monolithic zirconia prostheses: n = 30) 보철물 제작 후 2년간의 추적 관찰을 통해 임플란트 생존율, 변연골 흡수량, 치주낭 깊이, 치태지수, 출혈지수, 치석지수 및 합병증을 평가하였다. 결과: 모든 임플란트가 기능적 문제와 동요도 없이 100%의 생존율을 보였다. 변연골 흡수량은 관찰 12개월에 LP군이 MZ군 보다 더 적었으며 (P < .05), 임상 검사시 관찰 12개월의 치주낭 깊이 및 치석 지수는 LP군에서 더 높았다 (P < .05). 주된 합병증으로 MZ군에서 7개에서 1.5 mm 이상의 골흡수가 관찰되었으며, LP군에서 2개의 chipping이 관찰되었다. 결론: 본 연구의 한계 내에서, 구치부 임플란트 지지 보철물에서 리튬 디실리케이트가 프레스된 지르코니아 보철물은 단일구조 지르코니아 보철물과 함께 예지성 있는 치료방법으로 판단된다.

Purpose: The purpose of this study was to compare the clinical outcomes of lithium disilicate ceramic pressed zirconia prostheses and monolithic zirconia prostheses and to investigate the complications after two years of follow-up in posterior edentulous site. Materials and methods: A total 17 patients (male: 12, female: 5) were treated with 60 posterior fixed implant-supported prostheses (LP. lithium disilicate ceramic pressed zirconia prostheses: n = 30, MZ. monolithic zirconia prostheses: n = 30). After 24-month, clinical examination of Implant survival rate, marginal bone resorption, probing depth, plaque index, bleeding index, calculus and complications were evaluated. Results: There were no failed implants and all implants were normal in function without mobility. Marginal bone resorption was lower in LP group than MZ group at 12-month (P < .05), and 12-month probing depth and calculus deposit in LP group were significantly higher than MZ group (P < .05). Most common complications in MZ were marginal bone resorptions more than 1.5.mm and 2 chipping occurred in LP group. Conclusion: Within the limitations of the present study, lithium disilicate ceramic pressed zirconia is considered as a predictable treatment option as much as monolithic zirconia in posterior fixed implant-supported prostheses.

키워드

참고문헌

  1. Ha SR, Kim SH, Han JS, Yoo SH, Jeong SC, Lee JB, Yeo IS. The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study. J Adv Prosthodont 2013;5:187-97. https://doi.org/10.4047/jap.2013.5.2.187
  2. Imanishi A, Nakamura T, Ohyama T, Nakamura T. 3-D Finite element analysis of all-ceramic posterior crowns. J Oral Rehabil 2003;30:818-22. https://doi.org/10.1046/j.1365-2842.2003.01123.x
  3. Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications in fixed prosthodontics. J Prosthet Dent 2003;90:31-41. https://doi.org/10.1016/S0022-3913(03)00214-2
  4. Kelly JR, Benetti P. Ceramic materials in dentistry: historical evolution and current practice. Aust Dent J 2011;56:84-96. https://doi.org/10.1111/j.1834-7819.2010.01299.x
  5. Heffernan MJ, Aquilino SA, Diaz-Arnold AM, Haselton DR, Stanford CM, Vargas MA. Relative translucency of six all-ceramic systems. Part I: core materials. J Prosthet Dent 2002;88:4-9. https://doi.org/10.1067/mpr.2002.126794
  6. Drummond JL, King TJ, Bapna MS, Koperski RD. Mechanical property evaluation of pressable restorative ceramics. Dent Mater 2000;16:226-33. https://doi.org/10.1016/S0109-5641(00)00013-0
  7. Guess PC, Zavanelli RA, Silva NR, Bonfante EA, Coelho PG, Thompson VP. Monolithic CAD/CAM lithium disilicate versus veneered Y-TZP crowns: comparison of failure modes and reliability after fatigue. Int J Prosthodont 2010;23:434-42.
  8. Sorensen JA. The IPS Empress 2 system: defining the possibilities. Quintessence Dent Technol 1999;22:153-63.
  9. Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil 2010;37:641-52. https://doi.org/10.1111/j.1365-2842.2010.02094.x
  10. Hannink R, Kelly PM, Muddle BC. Transformation toughening in zirconia-containing ceramics. J Am Ceram Soc 2000;83:461-87. https://doi.org/10.1111/j.1151-2916.2000.tb01221.x
  11. Wiederhorn SM, Bolz LH. Stress corrosion and static fatigue of glass. J Am Ceram Soc 1970;53:543-8. https://doi.org/10.1111/j.1151-2916.1970.tb15962.x
  12. Suh DW, Kim YK, Yi YJ. A review of biocompatibility of zirconia: In vitro experiment. J Korean Acad Prosthodont 2018;56:391-5. https://doi.org/10.4047/jkap.2018.56.4.391
  13. Suh DW, Kim YK, Yi YJ. A review of biocompatibility of zirconia and bioactivity as a zirconia implant: In vivo experiment. J Korean Acad Prosthodont 2019;57:88-94. https://doi.org/10.4047/jkap.2019.57.1.88
  14. Sorrentino R, De Simone G, Tete S, Russo S, Zarone F. Fiveyear prospective clinical study of posterior three-unit zirconiabased fixed dental prostheses. Clin Oral Investig 2011;16:977-85. https://doi.org/10.1007/s00784-011-0575-2
  15. Sailer I, Gottnerb J, Kanelb S, Hammerle C. Randomized controlled clinical trial of zirconia-ceramic and metalceramic posterior fixed dental prostheses. Int J Prosthodont 2009;22:553-60.
  16. Batson ER, Cooper LF, Duqum I, Mendonca G. Clinical outcomes of three different crown systems with CAD/CAM technology. J Prosthet Dent 2014;112:770-7. https://doi.org/10.1016/j.prosdent.2014.05.002
  17. Lim HN, Yu B, Lee YK. Spectroradiometric and spectrophotometric translucency of ceramic materials. J Prosthet Dent 2010;104:239-46. https://doi.org/10.1016/S0022-3913(10)60131-X
  18. Kim HK, Kim SH. Effect of the number of coloring liquid applications on the optical properties of monolithic zirconia. Dent Mater 2014;30:e229-37. https://doi.org/10.1016/j.dental.2014.04.008
  19. Takeichi T, Katsoulis J, Blatz MB. Clinical outcome of single porcelain-fused-to-zirconium dioxide crowns: a systematic review. J Prosthet Dent 2013;110:455-61. https://doi.org/10.1016/j.prosdent.2013.09.015
  20. Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 2008;21:217-22.
  21. Baltzer A. All-ceramic single-tooth restorations: choosing the material to match the preparation--preparing the tooth to match the material. Int J Comput Dent 2008;11:241-56.
  22. Guess PC, Zhang Y, Thompson VP. Effect of veneering techniques on damage and reliability of Y-TZP trilayers. Eur J Esthet Dent 2009;4:262-76.
  23. Kim SY, Choi JW, Ju SW, Ahn JS, Yoon MJ, Huh JB. Fracture strength after fatigue loading of lithium disilicate pressed zirconia crowns. Int J Prosthodont 2016;29:369-71. https://doi.org/10.11607/ijp.4602
  24. Cochran DL, Buser D, ten Bruggenkate CM, Weingart D, Taylor TM, Bernard JP, Peters F, Simpson JP. The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: early results from clinical trials on ITI SLA implants. Clin Oral Implants Res 2002;13:144-53. https://doi.org/10.1034/j.1600-0501.2002.130204.x
  25. Yoo HS, Kang SN, Jeong CM, Yun MJ, Huh JB, Jeon YC. Effects of implant collar design on marginal bone and soft tissue. J Korean Acad Prosthodont 2012;50:21-8. https://doi.org/10.4047/jkap.2012.50.1.21
  26. Quirynen M, Naert I, van Steenberghe D, Teerlinck J, Dekeyser C, Theuniers G. Periodontal aspects of osseointegrated fixtures supporting an overdenture. A 4-year retrospective study. J Clin Periodontol 1991;18:719-28. https://doi.org/10.1111/j.1600-051X.1991.tb00063.x
  27. Mombelli A, van Oosten MA, Schurch E Jr, Land NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 1987;2:145-51. https://doi.org/10.1111/j.1399-302X.1987.tb00298.x
  28. Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.
  29. Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol 2002;73:322-33. https://doi.org/10.1902/jop.2002.73.3.322
  30. Cox JF, Zarb GA. The longitudinal clinical efficacy of osseointegrated dental implants: a 3-year report. Int J Oral Maxillofac Implants 1987;2:91-100.
  31. Lindquist LW, Rockler B, Carlsson GE. Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses. J Prosthet Dent 1988;59:59-63. https://doi.org/10.1016/0022-3913(88)90109-6
  32. Block MS, Kent JN. Factors associated with soft- and hardtissue compromise of endosseous implants. J Oral Maxillofac Surg 1990;48:1153-60. https://doi.org/10.1016/0278-2391(90)90531-6
  33. Menini M, Conserva E, Tealdo T, Bevilacqua M, Pera F, Signori A, Pera P. Shock absorption capacity of restorative materials for dental implant prostheses: an in vitro study. Int J Prosthodont 2013;26:549-56. https://doi.org/10.11607/ijp.3241
  34. Gracis SE, Nicholls JI, Chalupnik JD, Yuodelis RA. Shockabsorbing behavior of five restorative materials used on implants. Int J Prosthodont 1991;4:282-91.
  35. Duyck J, Van Oosterwyck H, Vander Sloten J, De Cooman M, Puers R, Naert I. Influence of prosthesis material on the loading of implants that support a fixed partial prosthesis: in vivo study. Clin Implant Dent Relat Res 2000;2:100-9. https://doi.org/10.1111/j.1708-8208.2000.tb00112.x
  36. Bassit R, Lindstrom H, Rangert B. In vivo registration of force development with ceramic and acrylic resin occlusal materials on implant-supported prostheses. Int J Oral Maxillofac Implants 2002;17:17-23.
  37. Hobkirk JA, Psarros KJ. The influence of occlusal surface material on peak masticatory forces using osseointegrated implant-supported prostheses. Int J Oral Maxillofac Implants 1992;7:345-52.
  38. Bremer F, Grade S, Kohorst P, Stiesch M. In vivo biofilm formation on different dental ceramics. Quintessence Int 2011;42:565-74.
  39. Le M, Papia E, Larsson C. The clinical success of tooth- and implant-supported zirconia-based fixed dental prostheses. A systematic review. J Oral Rehabil 2015;42:467-80. https://doi.org/10.1111/joor.12272
  40. Rinke S, Gersdorff N, Lange K, Roediger M. Prospective evaluation of zirconia posterior fixed partial dentures: 7-year clinical results. Int J Prosthodont 2013;26:164-71. https://doi.org/10.11607/ijp.3229
  41. Sax C, Hammerle CH, Sailer I. 10-year clinical outcomes of fixed dental prostheses with zirconia frameworks. Int J Comput Dent 2011;14:183-202.
  42. Burke FJ, Crisp RJ, Cowan AJ, Lamb J, Thompson O, Tulloch N. Five-year clinical evaluation of zirconia-based bridges in patients in UK general dental practices. J Dent 2013;41:992-9. https://doi.org/10.1016/j.jdent.2013.08.007
  43. Malkondu O, Tinastepe N, Akan E, Kazazoglu E. An overview of monolithic zirconia in dentistry. Biotech Biotech Equip 2016;30:644-52. https://doi.org/10.1080/13102818.2016.1177470
  44. Jang YS, Noh HR, Lee MH, Lim MJ, Bae TS. Effect of lithium disilicate reinforced liner treatment on bond and fracture strengths of bilayered zirconia all-ceramic crown. Materials (Basel) 2018;11:77. https://doi.org/10.3390/ma11010077
  45. Sundh A, Molin M, Sjogren G. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dent Mater 2005;21:476-82. https://doi.org/10.1016/j.dental.2004.07.013