• Title/Summary/Keyword: Implant Treatment

Search Result 1,621, Processing Time 0.023 seconds

상악골에서 Veneer 골이식과 동반된 즉시 임프란트 매식

  • Jeong, Jong-Cheol;Choe, Jae-Seon;Kim, Ho-Seong;Seong, Dae-Gyeong;Lee, Gye-Hyeok;Choe, Jae-Uk;Kim, Yeong-Hun
    • The Journal of the Korean dental association
    • /
    • v.37 no.1 s.356
    • /
    • pp.62-68
    • /
    • 1999
  • Patients who present with severe maxillary bone loss Secondary to trauma or resorption provide a unique diagnosis and difficulty in implant installation. To solve this problem, various bone grafting methods and graft materials can be used in these compromised cases. But for the patients required wide reconstruction, autogenous iliac bone has been used widely because of easy harvesting of much corticocancellous bone. Usually, implant installations are performed 6-12 months later after grafting. but this method necessary long treatment period and additional surgery. To avoid this disadvantages, bone grafting with immediate implant installations are frequently used. But special care is necessary to prevent postoperative complication in this method. We present three cases of veneer grafting with immediate implant installation. These patients had a knife-edge shaped alveolar bone due to labial alveolar bone loss. We reconstructed this alveolar bone with veneer grafting with iliac bone and performed immediate implant installation. There was no complications during healing periods in these three cases. Six months later, we found good survival of grafting bone and osseointegration of these implants, so we could perform prosthetic treatment successfully.

  • PDF

Correction of the Dorsal Contour Deformity Caused by Scoliosis with Silicone Implant (실리콘 보형물을 이용한 척추측만증 배부 윤곽변형 교정수술)

  • Park, Ji Ung;Cho, Sang Hun;Shin, Jong In;Kim, Chang Yeon
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.792-795
    • /
    • 2007
  • Purpose: Scoliosis is a multifactorial disorder caused by genetic, biochemical, developmental, neuromuscular factors and causes complex deformities which include skeletal deformity, pain, cardiovascular dysfunction, motor function disorder. Until now, the treatment of scoliosis have been focused on orthopedic correction, preservation of cardiopulmonary and neurologic function. But recently, as aesthetic demands increases, the needs for the correction or improvement of the trunk and extremity contour does. So, the correction of soft tissue contour deformity can be a new concept for the treatment of scoliosis. Methods: We corrected a deformed contour with prefabricated silicone implant in a scoliosis patient who had been operated for orthopedic correction previously. Submuscular pocket was made under trapezius and latissimus dorsi muscle. Silicone implant was placed in the pocket and fixed to thoracolumbar fascia with sutures. Results: We had a satisfactory results for the correction of contour deformity. There was no significant complication. Conclusion: Silicone implant is a new trial for the correction of scoliosis contour deformity. This method is simple, safe and brings on satisfactory results.

COMPLICATIONS ASSOCIATED WITH DENTAL IMPLANT SURGERY; CASE REPORT (임플란트 수술 시의 합병증; 증례 보고)

  • Lee, Hyun-Jin;Yeo, Duck-Sung;Lim, So-Yeon;An, Kyung-Mi;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.173-180
    • /
    • 2007
  • According to the increase in use of implants in clinical dentistry, new kinds of complications happen. Complications that can happen during implant placement are bleeding, nerve injury, jaw fracture, fenestration of maxillary sinus or nasal cavity, dehiscence, fenestration, injury of adjacent tooth. And complications that can happen after implant operation are infection, bleeding, hematoma, chronic sinusitis, peri-implantitis. Problems that are confronted during implant placement happen by inadequate preoperative treatment plan, inadequate consideration about individual anatomic difference, inadequate operation process and lack of experience of clinician. It is important that clinicians consider possible complications in advance and make a comprehensive treatment plan. We report the patient who was happened ramus fracture during block bone harvesting from ramus of severely atrophic mandible, the patient who came to emergency ward due to postoperative swelling and bleeding and the patient whose implant was migrated to maxillary sinus with a review of literature.

Design of Zr-7Si-xSn Alloys for Biomedical Implant Materials (생체의료용 임플란트 소재를 위한 Zr-7Si-xSn 합금설계)

  • Kim, Minsuk;Kim, Chungseok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.1
    • /
    • pp.8-19
    • /
    • 2022
  • The metallic implant materials are widely used in biomedical industries due to their specific mechanical strenth, corrosion registance, and superior biocompatability. These metallic materials, however, suffer from the stress-shielding effect and the generation of artifacts in the magnetic resonance imaging exam. In the present study, we develope a Zr-based alloys for the biomedical implant materials with low elastic modulus and low magnetic susceptibility. The Zr-7Si-xSn alloys were fabricated by an arc melting process. The elastic modulus was 24~31 GPa of the zirconium-based alloy. The average magnetic susceptibility value of the Zr-7Si-xSn alloy was 1.25 × 10-8cm3g-1. The average Icorr value of the Zr-7Si-xSn alloy was 0.2 ㎂/cm2. The Sn added zirconium alloy, Zr-7Si-xSn, is very interested and attractive as a biomaterial that reduces the stress-shielding effect caused by the difference of elastic modulus between human bone and metallic implant.

Sintered Properties and Microstructural Defects of Zirconia Ceramic Implant Fabricated by Injection Molding and Hot Isostatic Pressing (HIP) (사출성형 및 열간가압 소결법으로 제작된 지르코니아 세라믹 임플란트의 소결물성 및 미세구조적 결함)

  • Hyun Jung Park;Jeong Sik Park;Jong Kook Lee
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.4
    • /
    • pp.215-222
    • /
    • 2023
  • 3Y-TZP (3 mol% yttria-stabilized tetragonal zirconia polycrystals, 3Y-TZP) ceramics are emerging as dental implant materials due to their superior optical and mechanical properties as well as excellent biophysical properties, in spite of low bioactivity. In this study, we investigated to sintered properties and microstructural defects of dental zirconia implants fabricated by ceramic injection molding and post-HIP (Hot isostatic pressing) processing and analyzed the processing parameters related with the obtainment of its high sinterd density. Sintered and microstructural parameters, i.e, apparent density, grain size and phase composition of zirconia implants fabricated by injection molding were dependent on the fixtute size and implant type. Maximum sintered density of 99.2% and minimum grain size of 0.3-0.4 ㎛ were obtained from large-scaled 2-body sample. In 1-body ceramic implant, high sintered density of 99.5% was obtained, but it had a little monoclinic phase and wide grain size distribution.

Evaluation of prognosis related to compliance with supportive periodontal treatment in patients with chronic periodontitis: a clinical retrospective study

  • Lee, Jong-Bin;Shin, Hye-Jung;Kim, Dae-Yeob;Pang, Eun-Kyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.2
    • /
    • pp.76-89
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the prognostic effect of patient compliance with supportive periodontal treatment (PC-SPT). Chronic periodontitis patients were classified based on their compliance level, and factors affecting PC-SPT and the prognosis of PC-SPT were investigated. Methods: This study selected 206 patients who started SPT after receiving periodontal treatment between 2010 and 2012. Patients who continued SPT through February 2016 were included. The patients were classified according to whether they exhibited complete compliance (100% of visits), excellent compliance (${\geq}70%$ of visits), incomplete compliance (<70% of visits), or non-compliance (only 2 visits). Patient characteristics that could affect PC-SPT, such as age, sex, distance of the clinic from their residence, implantation, and periodontal treatment, were investigated. The number of newly decayed and extracted teeth, alveolar bone level changes around the teeth and implants, and implant removal were examined to evaluate the prognosis of PC-SPT. Results: Sex and the presence of an implant significantly affected PC-SPT. Additionally, the number of newly decayed and extracted teeth and changes in alveolar bone levels around the teeth and implants were significant prognostic factors related to PC-SPT. Conclusions: PC-SPT in chronic periodontitis patients will help maintain periodontal health and prevent further periodontal disease.

Screw and cement retained implant prosthesis rehabilitation of mandibular edentulous patients with severely absorbed ridge (치조제가 심하게 흡수된 하악 무치악환자의 나사-시멘트 유지형 임플란트 보철 수복증례)

  • Im, Joong-Jae
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.149-156
    • /
    • 2019
  • Purpose: Prosthodontics for edentulous patients is a treatment technique using implant, which has impactful results in retention and support effects. Methods: As a retention technique, SCRP (screw and cement retained implant prosthesis) has reported in many studies as a beneficial method for both patients and curers, which can reduce errors in process of making abutment and top implant. Results: Prosthesis manufacturing, as polymerization method of hardened resin teeth with thermoplastic resin, is helpful for patients with aesthetic and financial situations regarding residual ridge and interocclusal relationship, also indicates reliable results in both retention and care. Conclusion: Using SCRP technique, we notably obtained a clinical and aesthetic outcome from five implants in anterior tooth, which are half fixable and detachable implants on screw of implant abutment by the technicians at anytime.

Occlusal concepts and considerations in implant supported prosthesis (임플란트 지지 보철물의 교합양식 및 고려사항)

  • Baek, Yeon-Wha;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • The Journal of the Korean dental association
    • /
    • v.58 no.8
    • /
    • pp.496-504
    • /
    • 2020
  • The osseointegrated implants react biomechanically in a different pattern to occlusal force, due to lack of the periodontal ligament unlike the natural teeth. The implants show markedly less movement and limited tactile sensitivity compared with the natural teeth. The implant occlusion concept aims to avoid overloading on the implants and to direct occlusal loads along the longitudinal axis of the implants, in order to compensate for the different biomechanics of the implants. Although many guidelines and theories on implant occlusion have been proposed, few have provided strong supportive evidence. Moreover, the outcome of treatment often quite successful in spite of different concepts of occlusion and there is an increasing tendency to doubt about the strict theoretical implant-specific occlusion concept. The purpose of this article is to review the previous reports about the concept of implant occlusion and discuss clinical occlusal considerations in implant rehabilitations.

  • PDF

Histomorphometric evaluation of the implant designed by shape optimization technique (성견 경골에서 최적화 기법을 이용하여 형상 개선된 임프란트의 조직계측학적 분석)

  • Kwon, Hyuk-Rak;Moon, Sang-Kwon;Shim, Joon-sung;Ahn, Sei-young;Lee, Hun;Kim, Han-Sung;Choi, Seong-ho;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.35-48
    • /
    • 2004
  • Since the occlusal loading is transmitted to the surrounding bone, the success of an implant treatment is closely related to the distribution of the stress on the implant. The finite element analysis method is often used in order to produce a model for dispersion of stress. Assessment of the success of the implant is usually based on the degree of osseointegration which is a bone and implant surface interface. Implant used in this research was designed through the method of shape optimization after the stress on implant was anaylzed by the finite element analysis method. This study was pertinently assessed by a clinical, histologic, histomorphometric analysis after the shape optimized implant was installed on beagle dog tibia. The results are as follows 1. It clinically showed a good result without mobility and imflammatory reaction. 2. Implant was supported by dense bone and bone remodeling showed on the surrounding area of the implant 3. The average percentage of bone-implant contact was 58.1%.The percentage of bone density was 57.6%. Having above results, shape optimized implant showed the pertinence through clinical and histologic aspects. However, to use the shape optimized implant, the further experiment is required for finding problems, improvement.

Early implant failure: a retrospective analysis of contributing factors

  • Kang, Dae-Young;Kim, Myeongjin;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Caballe-Serrano, Jordi;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.287-298
    • /
    • 2019
  • Purpose: The aim of this retrospective study was to determine the prevalence of early implant failure using a single implant system and to identify the factors contributing to early implant failure. Methods: Patients who received implant treatment with a single implant system ($Luna^{(R)}$, Shinhung, Seoul, Korea) at Dankook University Dental Hospital from 2015 to 2017 were enrolled. The following data were collected for analysis: sex and age of the patient, seniority of the surgeon, diameter and length of the implant, position in the dental arch, access approach for sinus-floor elevation, and type of guided bone regeneration (GBR) procedure. The effect of each predictor was evaluated using the crude hazard ratio and the adjusted hazard ratio (aHR) in univariate and multivariate Cox regression analyses, respectively. Results: This study analyzed 1,031 implants in 409 patients, who comprised 169 females and 240 males with a median age of 54 years (interquartile range [IQR], 47-61 years) and were followed up for a median of 7.2 months (IQR, 5.6-9.9 months) after implant placement. Thirty-five implants were removed prior to final prosthesis delivery, and the cumulative survival rate in the early phase at the implant level was 95.6%. Multivariate regression analysis revealed that seniority of the surgeon (residents: aHR=2.86; 95% confidence interval [CI], 1.37-5.94) and the jaw in which the implant was placed (mandible: aHR=2.31; 95% CI, 1.12-4.76) exerted statistically significant effects on early implant failure after adjusting for sex, age, dimensions of the implant, and type of GBR procedure (preoperative and/or simultaneous) (P<0.05). Conclusions: Prospective studies are warranted to further elucidate the factors contributing to early implant failure. In the meantime, surgeons should receive appropriate training and carefully select the bone bed in order to minimize the risk of early implant failure.