COMPLICATIONS ASSOCIATED WITH DENTAL IMPLANT SURGERY; CASE REPORT
![]() |
Lee, Hyun-Jin
(Dept. of Dentistry, Oral & Maxillofacial Surgery, Daegu Catholic University Hospital)
Yeo, Duck-Sung (Dept. of Dentistry, Oral & Maxillofacial Surgery, Daegu Catholic University Hospital) Lim, So-Yeon (Dept. of Dentistry, Oral & Maxillofacial Surgery, Daegu Catholic University Hospital) An, Kyung-Mi (Dept. of Dentistry, Oral & Maxillofacial Surgery, Daegu Catholic University Hospital) Sohn, Dong-Seok (Dept. of Dentistry, Oral & Maxillofacial Surgery, Daegu Catholic University Hospital) |
1 | Tolman DE, Keller EE: Management of mandibular fracture in patients with endosseous implants. Int J Oral Maxillofac Implants 1991;6:427-436 |
2 | Regev E, Smith RA, Perrott DH, Pogrel MA: Maxillary sinus complications related to endosseous implants. Int J Oral Maxillofac Implants 1995;10:451-461 |
3 | Karlis V, Bae RD, Glickman RS: Mandibular fracture as a complication of inferior alveolar nerve transposition and placement of endosseous implants: a case report. Implant Dent 2003;12:211-216 DOI ScienceOn |
4 | Schonberg DC, Herbert DS, Jameson LM, et al.: Mandibular fracture through an endosseous implant. Int J Oral Masxillofac Implants 1992;7:401-404 |
5 | Iida S, Tanaka N, Kogo M, Matsuya T: Migration of a dental implant into the maxillary sinus: A case report. Int J Oral Maxillofac Surg 2000;29:358-359 DOI ScienceOn |
6 | Ueda M, Kaneda T: Maxillary sinusitis caused by dental implants:Report of two cases. J Oral Maxillofac Surg 1992;50:285- 287 DOI ScienceOn |
7 | Manson ME, Triplett RG, Van Sickles JE, et al.: Mandibular fracture through endosseous implants. Report of a case and review. J Oral Maxillofac Surg 1990;48:311-317 DOI ScienceOn |
8 | Flanagan D: Important arterial supply of the mandible, control of an arterial hemorrhage, and report of a hemorrhagic incident. J of Oral Implantology 2003;29:165-73 DOI ScienceOn |
9 | Galindo P, Sanchez-Fernandez E, Avila G, et al.: Migration of implants into the maxillary sinus: two clinical cases. Int J Oral Maxillofac Implants 2005;20:291-295 |
10 | Raghoebar GM, Vissink A: Treatment for an endosseous implant migrated into the maxillary sinus not causing maxillary sinusitis. Int J Oral Maxillofac Implants 2003;18:745-749 |
11 | Kan JY, Lozada JL, Boyne PJ, Goodacre CJ, Rungcharassaeng K: Mandibular fracture after endosseous implant placement in conjunction with inferior alveolar nerve transposition. Int J Oral Maxillofac Implants 1997;12:655-659 |
12 | Vercellotti T: Piezoelectric surgery in implantology: A case report- A new piezoelectric ridge expansion technique. Int J Periodont Restor Dent 2000;20:358-365 |
13 | Raghoebar GM, Stellingsma K, Batenburg RH, Vissink A: Etiology and management of mandibular fractures associated with endosteal implants in the atrophic mandible. Oral Surg Oral Med Oral pathol Oral Radiol Endod 2000;89:553-9 DOI ScienceOn |
14 | Sohn DS: Piezoelectric block bone graft in severely atrophic posterior maxilla with simultaneous implant placement. Dent Success 2003;10:1208-1213 |
15 | Mordenfeld A, Andersson L, Bergstrom B: Hemorrhage in the floor of the mouth during implant placement in the edentulous mandible. Int J Oral Maxillofac Implants 1997;12:558-561 |
16 | Tepper G, Hofschneider UB, Gahleitner A, Ulm C: Computed tomographic diagnosis and localization of bone canals in the mandibular interforaminal region for prevention of bleeding complications during implant surgery. Oral Maxillofac Implants 2001;16:68-72 |
17 | El Charkawi HG, El Askary AS, Ragab A: Endoscopic removal of an implant from the maxillary sinus: a case report. Implant Dent 2005;14:30-35 DOI ScienceOn |
![]() |