• 제목/요약/키워드: Implant Patient

검색결과 990건 처리시간 0.021초

Cranioplasty with the Porous Polyethylene Implant(Medpor) for Large Cranial Defect

  • Hong, Ki-Sun;Kang, Shin-Hyuk;Lee, Jang-Bo;Chung, Yong-Gu;Lee, Hoon-Kap;Chung, Heung-Seob
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권2호
    • /
    • pp.96-101
    • /
    • 2005
  • Objective : This paper describes our experience and implant technique for cranioplasty of a large cranial defects using a porous polyethylene implant[Medpor] and compares the results with polymethylmethacrylate[PMMA]. Methods : Sixteen cranioplasties were performed using Medpor[n= 10] and PMMA[n=6] implants between June 2003 and January 2005. The criterion for patient enrollment was a defect larger than 10cm in diameter. This study compared the operation times and complications. Results : The operation times ranged from 105 to 250minutes[Mean $180^{\circ}{\pm}44minutes$) in Medpor and from 185 to 460minutes [mean 128minutes] in PMMA. The absolute operation times were shorter using the Medpor implant and the differences were statistically significant[P=0.030]. Satisfactory cosmetic results were obtained in all cases using the Medpor implant and with no implant-related complications. Bone ingrowth to the medpor implant was presumed to be the result on an increase in Houndsfield units of the implant, particularly at the marginal areas in the serial follow-up brain computed tomography images. Conclusion : It is believed that the properties of a Medpor implant make this implant an good alternative to the existing methods of a cranial contour correction. However, a further follow-up study will be needed.

A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template

  • Youk, Shin-Young;Lee, Jee-Ho;Park, Ji-Man;Heo, Seong-Joo;Roh, Hyun-Ki;Park, Eun-Jin;Shin, Im Hee
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.395-405
    • /
    • 2014
  • PURPOSE. This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS. A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computerguided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (${\alpha}=.05$). RESULTS. The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION. In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery.

피질골 절단술을 이용한 수평면에서의 임플란트의 위치 교정에 대한 치험례 (A CASE REPORT ABOUT CORRECTION OF IMPLANT POSITION AT HORIZONTAL PLANE AFTER CORTICOTOMY)

  • 최빈;오해수;김진철;길용갑;김경수;김좌영
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권3호
    • /
    • pp.255-261
    • /
    • 2007
  • Preface: Dental implant is important method that may solve the mastication, occlusion, esthetic, temporomandibular joint, and psychologic problem in oral and maxillofacial surgery. It is ideal that all of the implant are well positioned by adequate technique. By the way it‘s not always possible because of some anatomic, physiologic factor. In this case, If the implant can be moved to adequate position, it may be possible more esthetically and implanted patients more satisfied, but the majority of Implantists and orthodontists have thought that it is not possible. However, Implant, in fact, can be moved. and thus we can overcome the limit of implantation more. The aim of the present study was to evaluate the possibility of implant movement after corticotomy. Case report: Patient missed the upper right first molar. and implantation was done after completion of socket healing. We wait six months for osseointegration. Then, corticotomy was done under local anesthesia and close coil was used for orthodontic force. After traction during 3 weeks, we find the change of implant position at horizontal plane. we can not see the degenerative change on adjacent structure and tracted implant. there is a clinical mobility on upper right second premolar that used for anchorage but it subside spontaneously at the timing of prosthetic restoration without additional treatment. Discussion: As we could have some knowledge with this experiment, we report the case of implant movement after corticotomy and suggest a method about more esthetic implant treatment with a review of literature.

심미적 영역에서 즉시 임플란트 식립 및 임시 수복을 통한 단일치의 수복에 대한 증례 보고 (Immediate implant placement and provisionalization of single implant in the esthetic region : Cases report)

  • 이성배;박유선;김병헌;이보아;최성호;김영택
    • 대한치과의사협회지
    • /
    • 제58권2호
    • /
    • pp.83-92
    • /
    • 2020
  • In the anterior maxillary area, dental implants for tooth replacement are challenging due to the need to satisfy high esthetic level as well as functionality. Immediate implant placement and provisionalization can dramatically reduce the edentulous period, and then fulfill patient's demand for esthetics. The aim of present case report is to demonstrate two cases that successfully restored single tooth with immediate implant placement and provisionalization in the anterior maxillary area. A 47 years old female was scheduled to replace her maxillary right central incisor due to crown-root fracture by trauma. Another 54-year-old female was planned to place dental implant following tooth extraction of maxillary right lateral incisor owing to continuous pus discharge despite repetitive treatments including apicoectomy. In these two cases, surgical and prosthetic procedures progressed in a similar way. After minimal flap elevation, atraumatic tooth extraction was performed. Implant was placed in proper 3-dimensional position and angulation with primary stability. Bone graft or guided bone regeneration for peri-implant bone defect was conducted simultaneously. Provisionalization without occlusal loading was carried out at the same day. Each definitive crown was delivered at 7 and 5 months after the surgery. Two cases have been followed uneventfully for 2 to 5 years of loading time. In conclusion, Immediate implant placement and provisionalization could lead to esthetic outcome for single tooth replacement with dental implant under proper case selection.

  • PDF

상악에 식립된 Frialit-2 임플란트의 성공률에 대한 후향적 연구 (Retrospective analysis of $frialit-2^{(R)}$ implant system placed in maxilla)

  • 채경준;정의원;김창성;심준성;조규성;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제35권2호
    • /
    • pp.449-460
    • /
    • 2005
  • Objectives Aim of this study was to evaluate the clinical use and the efficacy of Frialit-2 implant system. Experimental Methods Fifty nine patients received placement of Frilalit-2 implants(137 implants) in their maxillary anterior and posterior sites(40 and 97 implants). Intraoral & clinical examination, chart review and radiographs were taken from each patient. Results 1. The total implant survival rate was 92.7% after a mean follow-up period of 19.9 months. 2. The implant survival rate placed in anterior region was 97.5%. 3. The implant survival rate placed in posterior region was 90.7%. 4. The implant survival rate placed in atrophic posterior maxilla with advanced technique (GBR, Sinus elevation) was 87.2%. 5. The implant survival rate placed in type N(D4) bone was 82%, while 95.7% in type III (D3), and 100% in type II(D2) bone. 6. Most of the failed implants(7 of 10) were removed during the maintenance stage after prosthodontic treatment. Conclusion It was concluded that Frialit-2 implant could be used satisfactorily in the esthetic anterior region, but the use in the posterior region, especially with poor bone quality and quantity, further studies are needed.

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

엇갈린 교합 환자에서 임플란트 고정성 보철물을 이용한 수복증례 (Full mouth rehabilitation of the patient with crossed occlusion using implant fixed prosthesis: A case report)

  • 정병석;전영찬;정창모;윤미정;이소현;허중보
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.338-346
    • /
    • 2018
  • 엇갈린 교합 환자의 치료 방법은 피개의치, 이중관 의치를 사용하여 치료하거나 결손 부위에 임플란트를 식립함으로써 교합 지지를 회복해주는 방법이 있다. 잔존 치조골의 양이 양호하고 심미적, 기능적으로 임플란트 식립이 가능한 경우 임플란트 고정성 보철물 수복을 통해 환자에게 적절한 교합지지 및 기능, 편안함을 제공할 수 있다. 이 증례는 발치 후 심한 치조골 흡수가 동반되어 좌우 엇갈린 교합이 된 환자에서 상악동 골이식술 및 수직, 수평적 치조골 증대술을 실시하였다. 이후, 보철적으로 이상적 위치에 임플란트를 식립하였고 임시 보철물로 환자의 고유의 기능 및 심미를 평가한 후 이를 반영할 수 있는 double scanning technique을 사용하여 최종 보철물을 제작하였다. 이를 통해 엇갈린 교합을 성공적으로 극복하였으며, 저작 및 심미를 회복하여 만족스러운 결과를 얻었기에 이를 보고하고자 한다.

완전무치악환자의 전악 임플란트 치료 계획 수립을 위한 체계적인 접근법 (Rational treatment planning for implant treatment of the edentulous patients)

  • 배정인
    • 대한심미치과학회지
    • /
    • 제32권2호
    • /
    • pp.54-68
    • /
    • 2023
  • 디지털 방법을 사용한 무치악의 임플란트 치료계획은 surgical guide design으로 구체화된다. Surgical guide를 제작할 때, 우리는 먼저 최종 보철의 형태를 가상공간에 구현한 후 이를 바탕으로 식립 계획을 구체화하게 된다. 그러나 완전무치악 환자는 치아배열의 기준이 없고 악간관계가 정립되어 있지 않아 최종 보철의 형태를 짐작하기 어려워 surgical guide를 만드는 데 어려움이 있다. 이때 기존의 만족스러운 총의치나 부분의치, 잔존치 등이 존재한다면 그 치아배열이 가상적인 최종 보철의 reference가 될 수 있다. 만약 이러한 reference가 부재하거나 만족스럽지 못하다면, 진단용 목적으로 총의치를 제작하되 이를 구내에서 검증하는 과정이 필요하다. 이러한 과정을 통해 surgical guide를 제작할지라도 구내 상황에 따라 implant의 위치가 계획한 것과 다르게 식립될 수 있으며, 만약 guide의 positioning이 잘못된다면 그 오차는 모든 implant의 위치를 변위시킬 수 있으므로 guide 수술이 오히려 재앙으로 다가올 수 있다. 본 기고에서는 치아 배열의 reference가 될 수 있는 자료들을 적절한 시기에 채득하여 이를 디지털 공간에 이전 및 통일된 좌표계로 정렬하는 방법에 대해 논의하고, 또한 이렇게 수립된 식립계획을 현실의 구강에 적은 오차로 이전 및 정렬하는 방법에 대해 소개하여 일관적이고 체계적인 무치악 가이드 디자인의 프로토콜 정립에 대해 의견 개진하려 한다.

Full mouth fixed implant rehabilitation in a patient with generalized aggressive periodontitis

  • Huh, Yoon-Hyuk;Shin, Hyung-Joo;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.154-159
    • /
    • 2010
  • BACKGROUND. Generalized aggressive periodontitis (GAP) is a destructive periodontal disease that can develop in young age. Only a few cases of full mouth rehabilitation, using dental implants, have been reported in a patient with aggressive periodontitis. CASE DESCRIPTION. This clinical report describes the treatment procedures and results of full mouth rehabilitation in a patient with aggressive periodontitis. After all teeth were extracted, 6 implants were placed in the maxilla and mandible, respectively. Fixed detachable implant prostheses were made. The patient was satisfied with the final results. She was followed for 10 months postloading. CLINICAL IMPLICATION. For a long-term success, continuous maintenance care is critical, as the contributing factors of the disease (such as immune factors or periodontal pathogens) may not be controlled adequately.

컴퓨터 보조 기반 치아 지지 서지컬 템프레이트를 이용한 상악구치부 임플란트 식립 (Implant Fixture Installation in the Posterior Maxilla Using a Tooth-supported Surgical Template Based on Computer Assisted Treatment Planning)

  • 김성민;김명주;이지호;명훈;이종호;김명진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권6호
    • /
    • pp.381-389
    • /
    • 2013
  • Two patients with partial edentulous maxilla were scheduled to undergo installation of implant fixtures using a tooth-supported surgical template based on computer assisted treatment planning. After 3-dimensional (3D) computed tomographic scanning was transferred to the OnDemand3D (Cybermed Co., Seoul, Korea) software program for virtual planning, fixtures of MK III Groovy RP implant of the Br${\aa}$nemark System (Nobel Biocare AB Co., G$\ddot{o}$teborg, Sweden) was installed using the In2Guide (CyberMed Co., Seoul, Korea) tooth-supported surgical template with a Quick Guide Kit (Osstem Implant Co., Seoul, Korea) system in the posterior maxilla of each patient. Sinus floor elevation with a xenogenic bone graft procedure was also performed simultaneously in one patient. Fixture installations were completed successfully without complications, such as sinus mucosa perforation, bony bleedings, fenestrations, or others. During the last two-year follow-up period after prosthetics delivery, each implant was found to be fine with no other minor complications. The entire procedures are reported and the literatures on use of tooth-supported surgical template was reviewed.