• 제목/요약/키워드: Impeller Blades

검색결과 129건 처리시간 0.024초

Visualization of Relative Flow Patterns in Centrifugal Blood Pump

  • Chan, Weng-Kong;S.C.M Yu;L.P. Chua;Y.W. Wong
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1869-1875
    • /
    • 2001
  • The paper presents computational and flow visualization results on a centrifugal blood pump. 4 impeller designs were tested at a rotational speed of 2000 rpm using blood analog as working fluid. All impellers have seven blades but of different geometry (Impellers A3, A4, B2 and R7). Flow visualization within the impeller passages was conducted using an image de-rotation system. A pair of large scale vortices was found within the blades of impeller R7 while a single vortex was found in most of the passages of backward facing impellers (Impellers A3, A4 and B2). To establish the effects of blade geometry on blood cells, CFD was used to simulate the blade to blade flow to provide an estimate of the maximum shear stress. The results showed that though most of the stresses within the blade passages are below a threshold level of 150 N/m$^2$for extensive erythrocyte damage to occur, there are some regions near to the leading edge of the pressure side where the shear stresses a abode threshold level.

  • PDF

관류형팬의 설계변수 특성에 관한 연구 (A Study on Characteristics of Design Parameters for In-line Duct Fan)

  • 박진욱;허종철;이철형;박완순
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.373-377
    • /
    • 2005
  • The Performance of in-line duct fan depends on the design parameters of impeller and guide vane. such as sweep back angle of impeller, the number of blades, outlet blade angle, guide vane angle etc. In this experimental study total four kinds of impellers having different sweep back angles, $90^{\circ},\;72.5^{\circ},\;55^{\circ},\;37.5^{\circ}$ with 8 guide vanes, different the number of blades, 6ea, 8ea, 10ea, 12ea, different kinds of outlet blade angles, $30^{\circ},\;45^{\circ}.\;60^{\circ}$ and different kinds of guide vane angles, $15^{\circ},\;30^{\circ},\;45^{\circ}$ were selected and their performance measured to investigate the effects of them. The results were non-dimensionalized to compare their performance.

  • PDF

고속 원심홴의 공력성능 향상을 위한 에어포일 임펠러 적용 (Application of Airfoil Impeller for Enhancement of Aerodynamic Performance of High Speed Centrifugal Fan)

  • 박경현;박창환
    • 대한기계학회논문집B
    • /
    • 제40권5호
    • /
    • pp.321-327
    • /
    • 2016
  • 본 연구에서는 고속 회전을 하는 진공청소기용 원심홴의 공력성능 향상을 위해 에어포일 임펠러(Airfoil Impeller)의 적용을 검토 및 연구하였다. 에어포일 최대두께 및 최대두께 위치에 따라 3종의 에어포일 임펠러를 제시하였고, 이때 C4 에어포일 두께분포를 이용하였다. 에어포일 임펠러의 성능 평가는 전산유체역학(Computational Fluid Dynamics) 해석과 흡입일률시험을 통해 수행되었다. 이를 통해 에어포일 형상 적용 시 기존 블레이드 형상에 비하여 임펠러 블레이드 압력면과 디퓨져 블레이드 압력면에서 발생하는 유동박리가 크게 줄어드는 것을 확인하였다. 그리고 이로 인해 기존 원심홴에 비하여 홴 효율이 약 3% 증가 및 비소음이 약 1.3dB(A) 감소되는 것을 확인하였다.

디퓨저 베인에 기인한 공진조건에서의 임펠러 강제진동 및 구조응답 예측 (Forced Vibration and Structural Response Prediction for Impeller in Resonant Conditions due to Diffuser Vanes)

  • 김용세;공동재;신상준;박기훈;임강수
    • 한국추진공학회지
    • /
    • 제22권4호
    • /
    • pp.24-35
    • /
    • 2018
  • 원심압축기 임펠러의 블레이드는 임펠러와 디퓨저 베인 간 상호작용에 의해 발생하는 비정상 유동의 공력가진력이 공진조건에서 주기적으로 임펠러를 가진함에 따라 고주기피로 파손이 발생할 수 있다. 이에 대한 정밀한 구조응답 예측을 위해 유동해석과 구조해석을 각기 수행하여 공력가진력과 주요 공진조건을 도출하였다. 이 후 단일방향의 유체-구조 연성 기반의 강제진동 해석을 수행하고, 결과들을 토대로 고주기피로에 대한 구조 안전도를 평가할 수 있는 수치해석 절차를 구축하였다. 본 논문의 수치해석 절차는 임펠러 초기 설계단계에서 고주기피로 문제를 사전에 방지하는데 기여할 것으로 기대된다.

Prediction of Specific Noise Based on Internal Flow of Forward Curved Fan

  • Sasaki, Soichi;Hayashi, Hidechito;Hatakeyama, Makoto
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.80-91
    • /
    • 2009
  • In this study, a prediction theory for specific noise that is the overall characteristic of the fan has been proposed. This theory is based on total pressure prediction and broadband noise prediction. The specific noises of two forward curved fans with different number of blades were predicted. The flow around the impeller having 120 blades (MF120) was more biased at a certain positions than the impeller with 40 blades (MF40). An effective domain of the energy conversion of MF40 has extended overall than MF120. The total pressure was affected by the slip factor and pressure loss caused by the vortex flow. The suppression of a major pressure drop by the vortex flow and expansion of the effective domain for energy conversion contributed to an increase in the total pressure of MF40 at the design point. The position of maximum relative velocity was different for each fan. The relative velocity of MF120 was less than that of MF40 due to the deviation angle. The specific noise of MF120 was 2.7 dB less than that of MF40 due to the difference in internal flow. It has been quantitatively estimated that the deceleration in the relative velocity contributed to the improvement in the overall performance.

설계유량을 변수로 한 원심다익송풍기의 최적설계 (Design Optimization of A Multi-Blade Centrifugal Fan With Variable Design Flow Rate)

  • 서성진;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1726-1731
    • /
    • 2004
  • This paper presents the response surface optimization method using three-dimensional Navier-Stokes analysis to optimize the shape of a forward-curved blades centrifugal fan. For numerical analysis, Reynolds-averaged Navier-Stokes equations with $k-{\varepsilon}$ turbulence model are discretized with finite volume approximations. In order to reduce huge computing time due to a large number of blades in forward-curved blades centrifugal fan, the flow inside of the fan is regarded as steady flow by introducing the impeller force models. Three geometric variables, i.e., location of cut off, radius of cut off, and width of impeller, and one operating variable, i.e., flow rate, were selected as design variables. As a main result of the optimization, the efficiency was successfully improved. And, optimum design flow rate was found by using flow rate as one of design variables. It was found that the optimization process provides reliable design of this kind of fans with reasonable computing time.

  • PDF

설계유량을 변수로 한 원심다익송풍기의 최적설계 (Design Optimization of A Multi-Blade Centrifugal Fan With Variable Design Flow Rate)

  • 서성진;김광용
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1332-1338
    • /
    • 2004
  • This paper presents the response surface optimization method using three-dimensional Navier-Stokes analysis to optimize the shape of a forward-curved blades centrifugal fan. For numerical analysis, Reynolds-averaged Navier-Stokes equations with k-$\varepsilon$ turbulence model are discretized with finite volume approximations. In order to reduce huge computing time due to a large number of blades in forward-curved blades centrifugal fan, the flow inside of the fan is regarded as steady flow by introducing the impeller force models. Three geometric variables, i.e., location of cut off, radius of cut off, and width of impeller, and one operating variable, i.e., flow rate, were selected as design variables. As a main result of the optimization, the efficiency was successfully improved. And, optimum design flow rate was found by using flow rate as one of design variables. It was found that the optimization process provides reliable design of this kind of fans with reasonable computing time.

혼합기 블레이드 설계변수에 따른 입자의 혼합성능 연구 (Effects of Design Parameters of Mixer Blades on Particle Mixing Performance)

  • 황선필;박상현;손동우
    • 한국전산구조공학회논문집
    • /
    • 제30권4호
    • /
    • pp.363-370
    • /
    • 2017
  • 본 논문에서는 원통형 혼합기를 대상으로 블레이드의 각도, 길이, 개수 및 블레이드와 탱크 바닥과의 간극을 설계변수로 선정하고, 각각의 설계변수가 혼합성능에 미치는 영향을 분석하였다. 이산요소법을 이용하여 임펠러 회전에 의한 고체 입자의 혼합공정을 해석하였으며, 혼합지수를 도입하여 혼합성능을 정량적으로 평가하였다. 다양한 설계변수의 조합을 고려한 실험계획법으로 설계변수의 주효과와 교호작용을 분석함으로써, 블레이드 각도가 입자의 혼합성능에 가장 지배적인 영향을 미치며 간극의 영향은 상대적으로 작다는 결론을 도출할 수 있었다. 또한 가장 우수한 혼합성능을 보이는 설계변수의 조합을 제시하였다.

원심형 터보기계의 볼류트네의 유동특성에 관한 실험적 연구 (An Experimental Study on Flow Characteristics in Volute of Centrifugal Turbomachinery)

  • 전경준;주원구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.801-806
    • /
    • 2001
  • The objective of present study is to find the interaction between volute and impeller of the centrifugal turbomachinery with rectangular cross-sectional volute. Flow measurement were taken in shrouded impeller with 12 backward type blades by using a five-hole pressure probe. The measurements are carried out in 7 flow rate, respectively. Primary function of a centrifugal turbo machinery volute is to serve the flow from the impeller and diffuser to pipe system. For the off-design conditions, Influence of pressure distortion was shown by these measurements. As a result, It has caused the decrease of total efficiency of centrifugal turbomachinery. We have also taken data to design volute by these measurements.

  • PDF

토크 컨버터 내부 유동장 측정 (II) (Flow Field Measurements in a Torque Converter (II))

  • 유성출;장성국
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.82-87
    • /
    • 2009
  • LDV measurements were conducted on the planes between impeller blades of torque converter. The flow fields are extremely complex because they contain unsteady viscous three-dimensional flows. Besides of their complexity, the difference in rotor speeds between the impeller and turbine compound the flow effects. The good spatial resolution of the LDV allows measurements of the instantaneous flow structures within the impeller passage, yielding valuable information about the production automotive torque converter in realistic operating conditions. It was found that the mass flow rates are strongly related with the internal flow characteristics of torque converter.

  • PDF