Visualization of Relative Flow Patterns in Centrifugal Blood Pump

  • Chan, Weng-Kong (School of Mechanical & Production Engineering, Nanyang Technological University) ;
  • S.C.M Yu (School of Mechanical & Production Engineering, Nanyang Technological University) ;
  • L.P. Chua (School of Mechanical & Production Engineering, Nanyang Technological University) ;
  • Y.W. Wong (School of Mechanical & Production Engineering, Nanyang Technological University)
  • Published : 2001.12.01

Abstract

The paper presents computational and flow visualization results on a centrifugal blood pump. 4 impeller designs were tested at a rotational speed of 2000 rpm using blood analog as working fluid. All impellers have seven blades but of different geometry (Impellers A3, A4, B2 and R7). Flow visualization within the impeller passages was conducted using an image de-rotation system. A pair of large scale vortices was found within the blades of impeller R7 while a single vortex was found in most of the passages of backward facing impellers (Impellers A3, A4 and B2). To establish the effects of blade geometry on blood cells, CFD was used to simulate the blade to blade flow to provide an estimate of the maximum shear stress. The results showed that though most of the stresses within the blade passages are below a threshold level of 150 N/m$^2$for extensive erythrocyte damage to occur, there are some regions near to the leading edge of the pressure side where the shear stresses a abode threshold level.

Keywords

References

  1. Akamatsu T., Nakazeki T. and Itoh H., 1992, 'Centrifugal Blood Pump with a Magnetically Suspended Impeller.' Artificial Organs, Vol. 16, No.3, pp. 305-308
  2. Akamatsu T., Tsukiya T., Nishimura K., Park C. H. and Nakazeki T., 1995, 'Recent Studies oC the Centrifugal Blood Pump with a Magnetically Suspended Impeller,' Artificial Organs, Vol. 19, No.7, pp. 631-638
  3. Allen G. S., Murray K. D. and Olsen D. B., 1997, 'The Importance of Pulsatile and Nonpulsatile Flow in the Design of Blood Pumps,' Artificial Organs, Vol.21, No.8, pp. 922-928
  4. Borges J. E., 1990, 'A Three-Dimensional Inverse Method for Turbomachinery: Part I-Theory,' Journal of Turbomachinery, Vol 112, pp. 346-354
  5. Fagan W. F., Beeck M. A. and Kreitlow H., 1981, 'The Holographic Vibration Analysis of Rotating Objects Using a Retlective Image Derotator,' Optics and Lasers Engineering, Vol 2, pp. 21-32 https://doi.org/10.1016/0143-8166(81)90010-5
  6. FLUENT Version 4. 3 User's Guide, 1995, Fluent Inc.
  7. Lakshminarayana B., 1996, Fluid Dynamics and Heat Transfer of Turbomachinery. Wiley & Sons New York
  8. Leverett L. B., Hellums J. D., Alfrey C. P. and Lynch E. C., 1972, 'Red Blood Cell Damage by Shear Stress,' Biophyscial Journal, Vol 12, pp. 257-272
  9. Li H.D., 1997-99, 'Inverse Design and Optimization of Blood Pump Impeller using Computational Fluid Dynamics,' Final Research Report, Nanyang Technological University
  10. Minami K., El-Banayosy A., Posival R, Seggewi (H., Murray E., Korner M. and Korfer R., 1992, 'Improvement of Survival Rate in Patients with Cardiogenic Shock by using Nonpulsatile and Pulsatile Ventricular Assist Device,' Int. Journal of Artificial Organs, Vol 15, No. 12, pp. 715-721
  11. Nakata K., Shiono M., Orime Y., Hata M., Sezai A., Saitoh T. and Sezai Y., 1996, 'Effect of Pulsatile and Nonpulsatile Assist on Heart and Kidney Microcirculation with Cardiogenic Shock,' Artificial Organs, Vol 20, No 6, pp. 681-684
  12. Ohki H., Yoshinaga Y. and Tsutsumi Y., 1983, 'Visualization of Relative Flow Patterns in Centrifugal Impellers,' Proceedings of the 3rd International Symposium on Flow Visualization, pp. 723-727
  13. Sezai A., Shiono M., Orime Y., Nakata K., Hata M., Yamada R, Ida M., Kashiwazaki S., Kinishita J., Nemoto M., Koujima T., Sezai Y. and Saitoh T., 1997, 'Renal Circulation and Cellular Metabolism During Left Ventricular Assisted Circulation: Comparison Study of Pulsatile and Nonpulsatile Assists,' Artificial Organs, Vol 21, No.7, pp. 830-835
  14. Waddell P., 1976, 'Epicyclic Motion: A System for Real Time Examination,' Engineering Materials and Design, Vol. 20, pp. 2-4
  15. Yada I., Golding L., Harasaki H., Jacobs G., Koike S., Yozu R., Sato N., Fujimoto L., Snow J., Olsen D., Murabayashi S., Venkatesen V., Kiraly R. and Nose Y., 1983, 'Physiopathological Studies of Non-pulsatile Blood Flow in Chronic Models,' ASAIO, Vol. 29, pp. 520-525