• Title/Summary/Keyword: Impedance Measurement

Search Result 872, Processing Time 0.025 seconds

Characterization of Tribocorrosion Behaviour of CoCr Alloy by Electrochemical Techniques in Several Corrosive Media

  • Escudero, M.L.;Diaz, I.;Martinez Lerma, J.F.;Montoya, R.;Garcia-Alonso, M.C.
    • Corrosion Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.68-73
    • /
    • 2018
  • Substitution of hip and knee joints by CoCr alloys is in great demand due to their high wear resistance and good biocompatibility. Understanding of tribocorrosion in joint replacements requires study of variables such as coefficient of friction and the choice of a proper corrosive medium in wear-corrosion tests carried out in the lab. The objective of this study was to characterize tribocorrosion behaviour of CoCr alloy with low (LCCoCr) and high carbon (HCCoCr) contents in several corrosive media: NaCl, Phosphate Buffer Solution (PBS), and PBS with hyaluronic acid (PBS-HA). Tribocorrosion tests were carried out on a pin-on-disk tribometer with an integrated electrochemical cell. A normal load of 5N was applied on the alumina ball counterpart at a rotation rate of 120 rpm. Coefficient of friction (COF) was measured and tribocorrosion behaviour was characterized by in situ application of electrochemical techniques. HCCoCr alloy immersed in PBS-HA showed the best tribocorrosion behaviour with the lowest COF. In this case, in situ measurement of corrosion potential and the impedance data under wear corrosion process showed an active state while passive film was continuously destroyed without possibility of regeneration.

Lithium ion Transport Characteristics of Gel-Type Polymer Electrolytes Containing Lithium p-[Methoxyoligo(ethyleneoxy)] benzenesulfonates (리튬 p-[메톡시 올리고(에틸렌옥시)]벤젠설폰산염으로 제조된 젤형 고분자 전해질의 리튬 이온 운반 특성)

  • 허윤정;강영구;한규승;이창진
    • Polymer(Korea)
    • /
    • v.27 no.4
    • /
    • pp.385-391
    • /
    • 2003
  • Lithium p-[Methoxyoligo(ethyleneoxy)] benzenesulfonates (LiEOnBS) with different repeating unit of ethylene oxide were synthesized and were used for preparing gel-polymer electrolytes. The conductivities and lithium ion transference number were measured as a function of Li-salt concentration and repeating unit of ethylene oxide of the LiEOnBS. The maximum conductivity of the resulting gel-polymer electrolyte was found to be 4.89${\times}$10$\^$-4/ S/cm (LiEO7.3BS, 0.5 M) at 30$^{\circ}C$. The lithium ion transference number (t$\sub$Li$\sub$+//) measurement were performed by means of the combination do polarization and ac impedance methods in gel-polymer electrolytes. Lithium ion transference number was measured to be in the range of 0.75∼0.92 for the LiEOnBS containing gel-polymer electrolytes. The maximum t$\sub$Li$\sub$+// was obtained to be 0.92 for the 0.1 M LiEOnBS containing polymer electrolytes. The synthesized LiEOnBS showed single ion transport like characteristics when n was large than 3.

Modeling of a Thermal Voltage Converter and Development of AC-DC Transfer Difference Calculation Program (열전형 전압변환기의 모델링 및 교류-직류 변환 차이 계산 프로그램 개발)

  • Lee Jung-Nam;Kwon Sung-Won;Jung Jae-Kap;Lee Hyo-Kyoung;Park Jong-Kweon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.5 s.96
    • /
    • pp.455-464
    • /
    • 2005
  • We have proposed a model of a thermal voltage converter(TVC) using the trans-impedance of lossy transmission line and developed a calculation program for ac-dc transfer difference of the TVC. The proposed TVC consists of a thermo-element(f) and a range resistor wire connected in series at the center of coaxial cylinder. The range resistor wire is used to extend the measurement range of the n. The calculated ac-dc transfer differences of the proposed TVC by simulation agree well with the measured values within the uncertainties. The simulated and measured values are agreed within $1{\mu}V/V$ from 40 Hz to 10kHz, within $5{\mu}V/V$ from 20kHz to 100MHz, and within $12{\mu}V/V$ from 200kHz to 1 MHz.

A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit (지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

Design of Dual-band Stacked Meander Line Antenna with Double Coupled Line (이중 커플드 라인을 이용한 이중 대역 적층형 미앤더 라인 안테나)

  • Jung, Jin-Woo;Seo, In-Jong;Lee, Hyeon-Jin;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.10 s.113
    • /
    • pp.993-999
    • /
    • 2006
  • This paper presents the design simulation, implementation, and measurement of a miniaturized DCS, PCS / Satellite DMB dual-band stacked chip antenna with double coupled line for mobile communication terminals. A stacked meander is realized by using a via hole with height of 0.8 mm and a diameter of 0.35 mm to connect upper- and lower-layer meander sections for a reduction of the dimensions of the antenna. In addition the stacked meander chip antenna is extended by a double coupled-line to achieve two different radiation modes. A ratio of the first frequency and second frequency vary with the geometrical parameter of coupled lines. The fabricated antenna used FR-4 substrate with relative permittivity of 4.2. And its dimensions are $15.2{\times}7{\times}0.8mm^3$. The measured impedance bandwidth(VSRW<2) are 244 and 120 MHz at the operating frequency, respectively.

4-Way Power Divider Based on Substrate Integrated Waveguide for Satellite Communications (기판 집적 도파관 기술을 이용한 위성 통신용 4분기 전력 분배기)

  • Seo, Tae-Yoon;Lee, Jae-Wook;Lee, Taek-Kyung;Cho, Choon-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.721-728
    • /
    • 2009
  • Equal/unequal 4-way power divider suitable for satellite communication using SIW technology is presented in this paper. The control of positions of guiding posts provides equal or unequal power division ratios by maintaining the width of the SIW unchanged. In addition, the detailed descriptions for the proposed power divider include the general characteristics of radial waveguide, feeding part using coaxial cable, simple SIW structure, power-guiding posts, and transition for measurement. The comparison between the simulated and measured data shows a good agreement at a center frequency of 10 GHz. The measured input impedance bandwidths for equal and unequal power divisions are about 2.1 GHz and 3 GHz under the condition of less than VSWR 2:1, respectively.

PEMFC Characterization Study by in-situ Analysis Method (In-Situ 분석법에 의한 연료전지 특성 연구)

  • Kim, Young-Min;Lee, Jong-Hyun;Im, Se-Joon;Ahn, Byung-Ki;Lim, Tae-Won
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.3
    • /
    • pp.208-215
    • /
    • 2009
  • PEMFC stack power output is needed to be around 100 kW to meet the requirements of automotive application and scaling-up the active area of the stack cells will allow a higher power. In the case of scaling-up the active area of cells, it is difficult to obtain uniform in-plane internal conditions such as temperature, relative humidity and stoichiometry of the feed gas. These ununiformity with the location in the cell would affect both the performance and durability of the stack, so it is important to understand phenomena in the cell for improving them. In this study, the current density, electrochemical resistance and performance distribution measurement was performed to understand the ununiformity in a single cell using in-situ method; (1) Current Density Distribution (CDD) Device and (2) Segmented Cell Fixture. The influence of location of feed gas on the performance of a single cell was experimentally measured and discussed by using a segmented single cell which was composed of 8 compartments. The correlation between the location and performance in a single cell was discussed by these two tools and it was extended between the local characterization and the durability in a MEA by comparing the used cell with a fresh one. It was also studied in terms of electrochemistry by Electrochemical Impedance Spectroscopy.

Characteristics of The 1-3 Piezoelectric Composite Transducer Manufactured by Dicing-Filling Method (Dicing-Filling 방법으로 제작된 1-3 압전복합변환자의 특성)

  • Kim, W.S.;Yun, U.H.;Ok, C.I.;Kim, S.B.;Lee, J.K.;Lee, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.33-37
    • /
    • 2000
  • The 1-3 piezoelectric composite transducer with 75 volume percents PZT was fabricated by the dicing-filling method. The resonance modes of the 1-3 transducer have been studied with electric impedance measurement as a function of frequency. The fundamental frequencies of the planar and thickness mode were observed at 0.95MHz and 1.63MHz respectively, but the lateral mode was not observed. In the thickness mode, the electromechanical coupling coefficient of the 1-3 piezoelectric composite transducer, 0.54, was very closed to that of the single phase PZT(0.52). The pulse-echo response by exciting the 1-3 transducer with an electric pulse was observed from the water/reflector interface, and analyzed bandwidth by the spectrum of the impulse response. The quality factor Q for the 1-3 transducer was observed as 1.5 smaller than that of the single phase(80) and then the 1-3 transducer may be used to the broad band type transducer applications.

  • PDF

A Study on Dual Circular Polarized Patch Antenna with Compact Size (소형 이중 원형편파 패치안테나에 관한 연구)

  • Yun, Gi-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1537-1543
    • /
    • 2010
  • This paper describes a compact microstrip antenna with dual polarization characteristics. The antenna, receiving both a left-hand circularly polarized(LHCP) wave and a right-hand circularly polarized(RHCP) wave, can be used for a polarization diversity. A diamond-shaped patch with internal empty room is designed for impedance matching as well as size reduction. And slots are added around feeding point to improve input matching. The proposed antenna has been applied to GPS(global positioning system), operating at 1.57GHz. And, the proposed idea has been verified and estimated by simulation. The measurement results show that it has VSWR 2:1 bandwidth of 83MHz, 3dB axial bandwidth of about 58MHz, 3dB beamwidth of 90degree, and gain of 0dBi, respectively, for RHCP. Also, it has similar performances for LHCP.

Phase Transition and Relaxation Properties of Nonlinear-Optical KTP Single Crystal (비선형광학 단결정 KTP의 상전이 및 완화특성에 관한 연구)

  • Choi, Byung-Chun
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.386-393
    • /
    • 1998
  • We have carried out the measurements of complex dielectric constants with impedance/gain-phase analyzer using capacitor method and the experiments of high temperature X-ray powder diffraction with X-ray diffractometer using ${\theta}-2{\theta}$ scan method for the KTP single crystal which has the premium nonlinear optical properties. From the results of high temperature X-ray powder diffraction experiments, we have found that KTP does not undergo structural phase transition below $900^{\circ}C$. It is clear that KTP undergoes structural phase transition around $900^{\circ}C$ and belongs to orthorhombic above $900^{\circ}C$ still. However, we have applied phenomenological relation of dielectric relaxation to the results of complex dielectric measurement and have found that relaxation mechanism of KTP well satisfies the Cole-Cole relation over the temperature range from $-78^{\circ}C$ to $200^{\circ}C$. And also the relaxation time well satisfies the Vogel-Fulcher relation. It is regarded that the hopping and thermally activated diffusion mechanism may control the conduction behavior of KTP above $200^{\circ}C$.

  • PDF