Browse > Article

PEMFC Characterization Study by in-situ Analysis Method  

Kim, Young-Min (Eco-Technology Research Institute, Hyundai Motor Company)
Lee, Jong-Hyun (Eco-Technology Research Institute, Hyundai Motor Company)
Im, Se-Joon (Eco-Technology Research Institute, Hyundai Motor Company)
Ahn, Byung-Ki (Eco-Technology Research Institute, Hyundai Motor Company)
Lim, Tae-Won (Eco-Technology Research Institute, Hyundai Motor Company)
Publication Information
Transactions of the Korean hydrogen and new energy society / v.20, no.3, 2009 , pp. 208-215 More about this Journal
Abstract
PEMFC stack power output is needed to be around 100 kW to meet the requirements of automotive application and scaling-up the active area of the stack cells will allow a higher power. In the case of scaling-up the active area of cells, it is difficult to obtain uniform in-plane internal conditions such as temperature, relative humidity and stoichiometry of the feed gas. These ununiformity with the location in the cell would affect both the performance and durability of the stack, so it is important to understand phenomena in the cell for improving them. In this study, the current density, electrochemical resistance and performance distribution measurement was performed to understand the ununiformity in a single cell using in-situ method; (1) Current Density Distribution (CDD) Device and (2) Segmented Cell Fixture. The influence of location of feed gas on the performance of a single cell was experimentally measured and discussed by using a segmented single cell which was composed of 8 compartments. The correlation between the location and performance in a single cell was discussed by these two tools and it was extended between the local characterization and the durability in a MEA by comparing the used cell with a fresh one. It was also studied in terms of electrochemistry by Electrochemical Impedance Spectroscopy.
Keywords
PEMFC stack; Bipolar plate Current density distribution; segmented cell fixture;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 I. H. Oh, H. Y. Ha and T. H. Lee, Chemical IndustIy and Technology, 16, No.5, 431 (1998)
2 S. J. Lee and S. Mukergee, Electrochemica Acta, 43, 3693 (1998)   DOI   ScienceOn
3 Q. Dong, M. M. Mench, S. Cleghorn and U. Beuscherller, J. Electrochem. Soc., 152 (11) A2114-A2122, (2005)   DOI   ScienceOn
4 노영우, 김세훈, 정귀성, 손익제, 한국일, 안병기, :'운전 조건에 따른 PEM 연료전지 모델링 및 성능 분석', 한국수소 및 에너지 학회지, 제19권 제3호, pp. 209-216   과학기술학회마을
5 J.P.Meyers, R.M.Darling, J. Electrochem. Soc., 153(8) A1432-Al442, (2006)   DOI   ScienceOn
6 Jens T. Mueller and Peter M. Urban, J. Power Sources, 75, pp. 139-143, (1998)   DOI   ScienceOn
7 I. A. Schneider, M. H. Bayer, A. Wokaun and G. G. Scherer, J. Electrochem. Soc., 155(8) B783-B792, (2008)   DOI   ScienceOn