• 제목/요약/키워드: Immunity Test

검색결과 253건 처리시간 0.028초

Immunity Test for Semiconductor Integrated Circuits Considering Power Transfer Efficiency of the Bulk Current Injection Method

  • Kim, NaHyun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권2호
    • /
    • pp.202-211
    • /
    • 2014
  • The bulk current injection (BCI) and direct power injection (DPI) method have been established as the standards for the electromagnetic susceptibility (EMS) test. Because the BCI test uses a probe to inject magnetically coupled electromagnetic (EM) noise, there is a significant difference between the power supplied by the radio frequency (RF) generator and that transferred to the integrated circuit (IC). Thus, the immunity estimated by the forward power cannot show the susceptibility of the IC itself. This paper derives the real injected power at the failure point of the IC using the power transfer efficiency of the BCI method. We propose and mathematically derive the power transfer efficiency based on equivalent circuit models representing the BCI test setup. The BCI test is performed on I/O buffers with and without decoupling capacitors, and their immunities are evaluated based on the traditional forward power and the real injected power proposed in this work. The real injected power shows the actual noise power level that the IC can tolerate. Using the real injected power as an indicator for the EMS test, we show that the on-chip decoupling capacitor enhances the EM noise immunity.

Modeling and Prediction of Electromagnetic Immunity for Integrated Circuits

  • Pu, Bo;Kim, Taeho;Kim, SungJun;Kim, SoYoung;Nah, Wansoo
    • Journal of electromagnetic engineering and science
    • /
    • 제13권1호
    • /
    • pp.54-61
    • /
    • 2013
  • An equivalent model has been developed to estimate the electromagnetic immunity for integrated circuits under a complex electromagnetic environment. The complete model is based on the characteristics of the equipment and physical configuration of the device under test (DUT) and describes the measurement setup as well as the target integrated circuits under test, the corresponding package, and a specially designed printed circuit board. The advantage of the proposed model is that it can be applied to a SPICE-like simulator and the immunity of the integrated circuits can be easily achieved without costly and time-consuming measurements. After simulation, measurements were performed to verify the accuracy of the equivalent model for immunity prediction. The improvement of measurement accuracy due to the added effect of a bi-directional coupler in the test setup is also addressed.

전원주파수 교류자기장 내성평가용 대형 3-축 사각 헬름홀쯔 코일 시스템 제작 (Construction of Large 3-axis Square Helmholtz Coil system for the Power Frequendy Magnetic Field Immunity Test)

  • 유권상;김창석;정낙삼
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.905-909
    • /
    • 1995
  • 전원주파수 교류자기장 내성평가을 위하여 유도코일용 대형 3-축 사각 헬름홀쯔 코일 를 설계 .center dot. 제작하였다. 제작한 사각 헬름홀쯔 코일의 코일상수및 자기장 균일도를 측정하였으며, 3축 방향의 자기장 균일도는 컴퓨터 모사에의한 값과 잘 일치하였다. 자기장 균일도부터 교류자기장 내성평가에서 요구하는 유효시험공간을 결정 하였으며, 다회의 유도코일을 사용하므로써 낮은 전류로 큰 자기장을 요구하는 단속적 교류자기장 내성평가도 수행할 수 있음을 알 수 있었다.

  • PDF

음향 기기 및 TV 방송 수신기의 내성 시험용 기준 신호 분석 (Analysis of Reference Signal for Immunity Test of Sound System and Television Broadcast Receiver)

  • 최수나;최성웅;박승근
    • 한국전자파학회논문지
    • /
    • 제23권7호
    • /
    • pp.805-814
    • /
    • 2012
  • 무선기기의 간헐적인 신호 또는 높고 낮은 진폭의 주기적인 신호 전송은 오디오 주파수에 간섭 신호를 발생시켜 근접 거리에 설치된 음향 기기에 잡음을 발생시킨다. 최근 이와 관련하여 Global system for Mobile Communication(GSM) 폰과 유사하게 간헐적인 신호 전송을 하는 Long Term Evolution(LTE) 폰에 의한 오디오 잡음현상이 보고되었다. 현재 국내 KN20 규격에서는 잡음에 대한 내성 능력을 확보하기 위하여 음향 및 TV 방송수신기의 내성 시험 기준 신호로 변조 주파수 1 kHz Amplitude Modulation(AM) 80 %와 Code Division Multiple Access(CDMA) 신호를 이용하고 있다. 본 논문에서는 LTE 폰의 출시에 따라 기존의 내성 기준 신호 AM과 CDMA를 GSM과 LTE 폰이 발생시키는 오디오 잡음의 수준과 비교한 후, 국내 음향 기기에 대한 내성 기준 신호의 개선을 제안한다. CDMA 신호는 음향 기기에 간섭을 거의 일으키지 않는 것으로 여겨지므로 시험 항목에서 삭제해도 무방할 것으로 판단된다. 반면, LTE는 많은 사용자가 이용하고 있으며, 음향 기기 등에 무시할 수 없는 간섭을 발생시킬 것으로 분석되므로 CDMA 신호를 대신하여 음향 기기 및 TV 방송 수신기의 내성 시험을 위한 시험 기준 신호로 규정하는 것이 바람직할 것으로 사료된다.

가미방기황기탕(加味防己黃芪湯) 주정 추출물이 류마티스 관절염 동물병태모델에 미치는 영향 (Effects of GamiBangkeehwangkee-tang (fángjǐhuángqí-tāng) ethanol extract on Collagen-induced Rheumatoid Arthritis model of DBA/1 mice)

  • 심부용;최학주;박지원;김동희
    • 대한본초학회지
    • /
    • 제29권6호
    • /
    • pp.95-102
    • /
    • 2014
  • Objectives : The purpose of this study is to prove the effect of GamiBangkeehwangkee-tang (f$\acute{a}$ngj$\check{i}$hu$\acute{a}$ngq$\acute{i}$-t$\bar{a}$ng, BHT) ethanol extract on the immunity and rheumatoid arthritis related inflammatory cytokines. Methods : We checked viability in RAW 264.7 cell after treat by BHT. Then we measured inflammatory and immunity factors of DBA/1 mice with rheumatoid arthritis induced by collagen after BHT oral administration. Also, we checked micro-CT image, bone volume and bone inflammation ratio in micro-CT and structural parameter test. Results : BHT showed cell viability of 95% or higher in all concentration in RAW 264.7 cells. BHT treated group decreased level in serum of IgM and IgG test by 36% and 25% respectively. And BHT treated group showed significant decrease in WBC, neutrophil, lymphocyte and monocytes immune cell ratio in blood by 47%, 22%, 56% and 85% respectively. Also, BHT treated group decreased level in serum of $IL-1{\beta}$, IL-6, IL-17, $TNF-{\alpha}$ and hs-CRP tests by 29%, 33%, 32%, 24% and 56% respectively. Finally, BHT treated group showed increase ratio of bone volume that decrease ratio of bone inflammation. Conclusions : In this study, the results were observed rheumatoid arthritis factors cytokine decrease in serum. And BHT showed immunoglobulin and immune cells ratio decrease in serum and blood. Also, BHT depending on effects of inflammatory and immunity in hs-CRP test, micro-CT, structural parameter test. Thus, these results can used as a effective drug of BHT for inflammation and immunity.

전자의료기기의 전자파 적합성 평가에 관한 연구 (A Study on the Electromagnetic Compatibility Evaluation of the Electronic Medical Instrumentation)

  • 송철규;김종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.418-421
    • /
    • 2002
  • The immunity testing in this study was performed to examine the conducted immunity and radiated immunity in medical instrumentation. Experiments were performed to assess the conducted emission and radiated emission of medical instrumentation such as MRI, ultrasound system, and electro surgical unit etc. The emission testing revolves around conducted emissions (high-frequency currents) on power lines and signal cables. Emission testing also looks at the output of energy through the air (called radiated emissions) and analyzes the strength of those radio-frequency signals generated unintentionally by the electrical medical device that is under test. Finally, this study would provide significant data for furture research or electromagnetic interference and compatibility test in medical instrumentation.

  • PDF

효율적인 ESD(ElectroStatic Discharge) test를 위한 Stress mode 제안 (Stress mode proposal for an efficient ESD test)

  • 강지웅;장석원;곽계달
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1289-1294
    • /
    • 2008
  • Electrostatic discharge(ESD) phenomenon is a serious reliability concern. It causes approximately most of all field failures of IC. To quality the ESD immunity of IC product, there are some test methods and standards developed. ESD events have been classified into 3 models, which are HBM, MM and CDM. All the test methods are designed to evaluate the ESD immunity of IC products. This study provides an overview among ESD test methods on ICs and an efficient ESD stress method. We have estimated on all pin combination about the positive and negative ESD stress. We make out the weakest stress mode. This mode called a worst-case mode. We proposed that positive supply voltage pin and I/O pin combination is efficient because it is a worst-case mode.

  • PDF

범용 CMOS 공정을 사용한 DTMOS 슈미트 트리거 로직의 구현을 통한 EM Immunity 향상 검증 (DTMOS Schmitt Trigger Logic Performance Validation Using Standard CMOS Process for EM Immunity Enhancement)

  • 박상혁;김소영
    • 한국전자파학회논문지
    • /
    • 제27권10호
    • /
    • pp.917-925
    • /
    • 2016
  • 슈미트 트리거 로직(Schmitt Trigger Logic)은 디지털 회로의 노이즈에 대한 내성을 향상시키기 위해 히스테리시스 특성을 보이는 게이트를 제안한 설계 방법이다. 슈미트 트리거 특성을 보이는 설계 방법 중 최근에 제안된 substrate bias를 조정하여 구현하는 Dynamic Threshold voltage MOS(DTMOS) 방법을 사용할 경우, 게이트 수를 늘이지 않고 내성을 향상 시킬 수 있는 설계방법이나, 범용 CMOS 공정에서 구현하여 시뮬레이션으로 예상하는 성능을 얻을 수 있는지는 검증되지 않았다. 본 연구에서는 $0.18{\mu}m$ CMOS 공정에서 DTMOS 설계 방법을 구현하여 히스테리시스 특성을 측정하여 검증하였다. DTMOS 슈미트 트리거 버퍼, 인버터, 낸드, 노어 게이트 및 간단한 디지털 로직 회로를 제작하였으며, 히스테리시스 특성, 전력 소모, 딜레이 등의 특성들을 관찰하고, 일반적인 CMOS 게이트로 구현된 회로와 비교하였다. 노이즈에 대한 내성이 향상되는 것을 Direct Power Injection(DPI) 실험을 통해 확인하였다. 본 논문을 통해 제작된 DTMOS 슈미트 트리거 로직은 10 M~1 GHz 영역에서 전자파 내성이 향상된 것을 확인할 수 있었다.

전자식 계기 IEC 61000-4-6 EMS 시험표준 적용 타당성 연구 (A Study About the Application Feasibility of EMS IEC 61000-4-6 Test Standard on Electronic Power Meter)

  • 김석곤;박창호;신동열;송태승;최용성
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1261-1267
    • /
    • 2011
  • Electricity meters using in Korea are about 1.8 million units. From among these, electronic meters for high voltage, about 170 thousand units were installed to the digital type meter and ones for low voltage installed hundreds of thou-sands of meters through a model project. Recently, low voltage meter are expected to complete the installation within several years. Domestic power metering technology is being beyond a simple framework with an electronic type and is rapidly evolving to intelligent smart metering systems in conjunction with promotion of a national smart grid project. Accordingly, it is important to ensure an immunity of meter for electromagnetic field and environmental noise at the installation site. In this paper, we are going to check the validity of international standard that focusing on RF electromagnetic field immunity of meter to secure the quality and improve the reliability in field operation of meter. And we will verify the validity of test specification focused on actual installation environment and are going to offer the improvement plan of test standard.

아로마 손 마사지가 밤 근무 간호사의 스트레스 반응 및 IgA에 미치는 효과 (Effects of Hand Massage with Aroma Oil on Stress Responses and Serum Immunity of Registered Nurse during the Night Duty)

  • 이혜숙;황혜숙;김영아
    • 한국간호교육학회지
    • /
    • 제13권2호
    • /
    • pp.169-176
    • /
    • 2007
  • Purpose: The purpose of this study was to verify the effect of aromatherapy hand massage on stress responses and serum Immunity of RN's before the night duty. Method: The data were collected during the period from Oct. 10 to Nov. 15, 2005 at S-Hospital in Seoul. There were forty-eight subjects, 24 for the experimental and 24 for the control group. A Pre & post test were conducted to measure pulse rate, perceived stress(level and score) and a blood sample for cortisol and IgA. In the experimental group, lavender and geranium were used. Data were analyzed by descriptive statistics, $x^2$-test and t-test with SPSS program. Result: The pulse rate was reduced but there were no significant differences between the two groups. Scores of subjective stress(VAS) decreased significantly after aromatherapy hand massage and the level of serum Cortisol was reduced significantly. The level of serum IgA was elevated significantly. Conclusion: Aromatherapy hand massage could be a useful intervention to reduce stress and elevate the immunity of nurses during the night duty.

  • PDF