• Title/Summary/Keyword: Images quality

Search Result 3,156, Processing Time 0.03 seconds

Noise2Atom: unsupervised denoising for scanning transmission electron microscopy images

  • Feng Wang;Trond R. Henninen;Debora Keller;Rolf Erni
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.23.1-23.9
    • /
    • 2020
  • We propose an effective deep learning model to denoise scanning transmission electron microscopy (STEM) image series, named Noise2Atom, to map images from a source domain 𝓢 to a target domain 𝓒, where 𝓢 is for our noisy experimental dataset, and 𝓒 is for the desired clear atomic images. Noise2Atom uses two external networks to apply additional constraints from the domain knowledge. This model requires no signal prior, no noise model estimation, and no paired training images. The only assumption is that the inputs are acquired with identical experimental configurations. To evaluate the restoration performance of our model, as it is impossible to obtain ground truth for our experimental dataset, we propose consecutive structural similarity (CSS) for image quality assessment, based on the fact that the structures remain much the same as the previous frame(s) within small scan intervals. We demonstrate the superiority of our model by providing evaluation in terms of CSS and visual quality on different experimental datasets.

A Study on the Using Drone Images in Cadastral Resurvey (지적재조사 드론 영상 활용방안 연구)

  • Keo Bae Lim;Seoung Hun Bae;Won Hui Lee;Boeun Kim;Yeongju Yu;Jin Kim
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.259-267
    • /
    • 2023
  • At a time when the demand for drones is increasing, a plan to utilize drone images was sought for efficient promotion of cadastral resurvey. To achieve the purpose of this study, the technical and legal status of drone images was reviewed, and through this, the possibility of using it for cadastral resurvey was primarily reviewed. subsequently, an experiment was conducted targeting the project district to examine whether drone images were applied to boundary extraction, which is the primary process of cadastral resurvey. As a result of the experiment, it was found that boundary extraction from images is possible. However, in some cases, it is impossible due to field conditions or image quality. Therefore, it is necessary first to apply cases where boundary extraction is possible to cadastral resurvey and seek solutions for some impossible cases. In particular, the image quality problem may have problems with the current technology, but it will also have problems with the existing drone equipment. So, standard for drone calibration should also be established. Finally, the cadastral resurvey surveying procedure using drones was also presented

Quality Evaluation of Drone Image using Siemens star (Siemens star를 이용한 드론 영상의 품질 평가)

  • Lee, Jae One;Sung, Sang Min;Back, Ki Suk;Yun, Bu Yeol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.3
    • /
    • pp.217-226
    • /
    • 2022
  • In the view of the application of high-precision spatial information production, UAV (Umanned Aerial Vehicle)-Photogrammetry has a problem in that it lacks specific procedures and detailed regulations for quantitative quality verification methods or certification of captured images. In addition, test tools for UAV image quality assessment use only the GSD (Ground Sample Distance), not MTF (Modulation Transfer Function), which reflects image resolution and contrast at the same time. This fact makes often the quality of UAV image inferior to that of manned aerial image. We performed MTF and GSD analysis simultaneously using a siemens star to confirm the necessity of MTF analysis in UAV image quality assessment. The analyzing results of UAV images taken with different payload and sensors show that there is a big difference in σMTF values, representing image resolution and the degree of contrast, but slightly different in GSD. It concluded that the MTF analysis is a more objective and reliable analysis method than just the GSD analysis method, and high-quality drone images can only be obtained when the operator make images after judging the proper selection the sensor performance, image overlaps, and payload type. However, the results of this study are derived from analyzing only images acquired by limited sensors and imaging conditions. It is therefore expected that more objective and reliable results will be obtained if continuous research is conducted by accumulating various experimental data in related fields in the future.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

The Influence of Service Quality Factors on Reuse Intention (항공사의 유·무형, 인적서비스 품질요인이 재이용의도에 미치는 영향 : 항공사 브랜드 및 브랜드태도의 매개효과를 중심으로)

  • Park, Hye-Yoon;Park, So-Yeon
    • Journal of Distribution Science
    • /
    • v.15 no.4
    • /
    • pp.59-67
    • /
    • 2017
  • Purpose - This study's aims are to examine the effects of airline service quality on brand image, brand attitude and reuse intention and the mediating roles of brand image and brand attitude in the relationship between airline service quality and reuse intention. Research design, data and methodology - A total of 500 questionnaire copies were distributed and 474 were used for the empirical study after excluding some empirical inappropriate or unusable ones. To analyze the collected data, the SPSS/WIN 22.0 statistical package was used. Results - The result of analysis showed that all the intangible, tangible and human elements of the airline service quality positively influenced on brand image and brand attitude and did not directly influence on reuse intention. However, brand image and brand attitude played mediating roles in the relationship between all the service quality elements and reuse intention. Conclusions - This means that airlines need to develop service quality, which is differentiated and provides special feelings for customers and work out improvement strategies for positive brand images and attitudes, since customers choose and reuse airlines, based on brand images and attitudes, which are perceived and formed through the experience of airline service quality and word of mouth.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

Compression of 3D color integral images using 2D referencing technique (2차원 참조 기법을 이용한 3D 컬러 집적 영상의 압축)

  • Kim, Jong-Ho;Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2693-2700
    • /
    • 2009
  • This paper proposes an effective compression method to utilize the 3D integral image with large amount of data obtained by a lens array in various applications. The conventional compression methods for still images exhibit low performance in terms of coding efficiency and visual quality, since they cannot remove the correlation between elemental images. In the moving picture compression methods, 1D scanning techniques that produce a sequence of elemental images are not enough to remove the directional correlation between elemental images. The proposed method effectively sequences the elemental images from an integral image by the 2D referencing technique and compresses them using the multi-frame referencing of H.264/AVC. The proposed 2D referencing technique selects the optimal reference image according to vertical, horizontal, and diagonal correlation between elemental images. Experimental results show that compression with the sequence of elemental images presents better coding efficiency than that of still image compression. Moreover, the proposed 2D referencing technique is superior to the 1D scanning methods in terms of the objective performance and visual quality.

Socio-cultural Meanings in Advertisement of Fashion Luxury Products -Focused on Women`s Images- (패션명품 광고에 나타난 사회문화적 의미 -여성 이미지를 중심으로-)

  • Yang, Sook-Hi;Hahn, Soo-Yeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.2
    • /
    • pp.267-278
    • /
    • 2005
  • Fashion luxury products, which used to mean high-quality, handcrafted not-so-trendy items, are nowadays regarded as expensive fashion merchandise produced under the name of imported well-known brands. People cunsuming fashion luxury products distinguish themselves from other people according to the luxury fashion brands they are using, and as a result, advertisements of fashion luxury products are taken as a kind of international language. The purpose of this study is to point out the socio-cultural meanings of consuming fashion luxury products, by analyzing images shown in advertisements of fashion luxury products focusing on women's images. To do so, this study is based on general theoretical background on fashion, consumer culture advertising and analysis advertisements of fashion luxury products shown in fashion magazines in recent three years. The result of this study is as follows; The images of the advertisements of fashion luxury products could be categorized as (1) elegance, (2) kitsch and (3) fetish. Elegance is a taste of high society, aesthetically chic and feminine. Fashion luxury products, which are merchandise of extravagance, dignity, refinement, feminity and harmony, exhibit high-quality grace through their advertisements. Kitsch represents the vulgar and popular images of trivial commodities of industrial society. In the advertisement of fashion luxury product, it is shown as inappropriateness, excessiveness, stereotyped pleasantness, exaggeration an playful satisfaction. Finally, fetish images represent erotic or perverted sexuality, based on psychoanalytic fetishism which objects are regarded s substitute of sexual orgasm. The advertisements of fashion luxury product are characterized as (1) popularization of luxury, (2) objectification of sex and body, and (3) re-aestetification of anti-aesthetics. The asvertisements of fashion luxury products are actually targeted to the middle class with successful career women's images. They objectify female bodies through fetishistic images. Also, the deviant subcultural style, represented a new kind of cultural capital, is now reproduced as a new commodity aesthetics.

Circuit Design for Compesation of a Dry Fingerprint Image Quality on Charge Sharing Scheme (전하분할 방식의 건조 지문이미지 보상회로 설계)

  • Jung, Seung-Min;Yeo, Hyeop-Goo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.795-797
    • /
    • 2013
  • This paper describes a charge sharing capacitive-sensing circuit technique that improves the quality of images captured with fingerprint sensor LSIs. When the finger is dry, the electrical resistance of a finger surface is high. It leads to poor image quality. To capture clear images even when the finger is dry, the modified capacitive detection circuit improves the image quality using an enhancement plate at the finger surface and a voltage control circuit. The test circuit is analyzed on $0.35{\mu}m$ CMOS process.

  • PDF

Electric power characteristic test of diagnostic X-ray high voltage transformer by input power condition (고전압트랜스포머의 진공이 방사선출력 노이즈에 미치는 영향)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Young-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.499-499
    • /
    • 2008
  • High voltage transformer of Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. High voltage transformer of diagnostic X-ray system has been usefully used for diagnostic purpose but if high voltage transformer performances are deteriorated, low quality image will be archived. In this case, operator has to exposure to get a more good quality images. In this case, unexpected radiation could be exposed to patient and it is very harmful to the patient. And I would like to design and make equipment to checkable high voltage transformer performance after that I wish to test and study what it is most influences in radiation output quality.

  • PDF