• Title/Summary/Keyword: Image quality evaluation table

Search Result 22, Processing Time 0.031 seconds

컴퓨터단층촬영 검사 시 테이블 높이에 따른 화질 특성에 관한 연구 (A Study on Characteristic of Image Quality according to CT Table Height in Computed Tomography )

  • 김기원;민정환;이상선;이영봉;이기종;박한솔;오주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권4호
    • /
    • pp.295-301
    • /
    • 2023
  • In addition to protocol adjustments during CT examinations, the height of the CT table can also affect image quality. Therefore, this study aimed to investigate the change in image quality depending on the height of the table in brain CT, which accounts for a large proportion of CT examinations, by measuring signal to contrast to noise ratio (CNR) and noise power spectrum (NPS) using the head phantom and evaluating them. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. The CNR result showed the highest value at 965 mm, which is the height adjacent to the center of the head phantom. NPS showed the lowest NPS at 915 mm, the center of the head phantom in the low frequency region. From these results, it can be seen that the height of the table in CT examination is closely related to the image quality, and it can be seen the characteristics of image quality according to CT table through quantitative evaluation methods such as CNR and NPS.

한.일 화질평가표에 의한 우리나라 위장조영검사의 품질관리 (Quality Control of Upper Gastrointestinal Series(UGIS) by The Image Quality Evaluation Table of Korea and Japan)

  • 오혜경;김정민;김창균;박영선;선종률;최인석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.277-285
    • /
    • 2011
  • 위장조영검사(UGIS)의 품질관리(quality control)를 위해 우리나라를 대표하는 종합검진기관 21곳에서 수검자 105명에 대한 위장조영촬영 영상 표본을 획득하였다. 표본 영상을 두 나라의 위장조영검사 화질평가표에 의해 각각 평가한 결과 우리나라 화질평가표(Image Quality Evaluation Table; IQET)에 의한 평균점수는 73.3점에 표준 오차 4.49로 21개 검진기관 중 19개 기관이 적격 판정을 받았다. 이에 반해 일본의 화질평가표에 의한 평균점수는 58점에 표준오차 4.45로 적격판정을 받은 기관은 불과 8곳 밖에 되질 않았다. 동일한 영상을 다른 평가표로 평가한 결과에 큰 차이를 보였다. 원인을 알아보기 위해 화질 평가표를 각각 항목별로 분석하여 위 전체영역의 묘출확인과 촬영기술에 대한 문제점을 파악하였고 획득된 영상으로 각 종합검진기관의 위장조영검사의 실태를 분석하였다. 우리나라 위장조영검사의 가장 큰 문제점은 명확한 검진방법 없이 검사가 시행되고 있다는 점이었다. 종합검진기관 21곳 모두 위장조영촬영방법이 모두 다를 뿐더러 앞벽 이중조영 촬영은 대부분 시행하지 않고 있었고 우리나라 화질 평가표에 포함하도록 명시된 점막상이나 식도영상을 포함하지 않는 종합검진기관도 있었다. 또한 체위에 따른 중복촬영이 시행되고 있어 수검자에 대한 무분별한 피폭선량에 대한 문제도 발생하고 있었다. 이에 적절한 위장조영검사의 품질관리를 통해 진단정보가 충분한 영상을 획득할 수 있도록 노력해야 할 것이다.

전산화단층촬영 테이블의 에어 매트리스 적용에 따른 환자의 편안함과 화질 변화 (Changes in the Comfort and Image Quality of the Patient According to the Application of Air Mattresses in the Computed Tomography Table)

  • 이영희;이용기
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.889-896
    • /
    • 2022
  • 본 연구는 전산화단층촬영의 테이블에 에어 매트리스의 적용으로 인한 환자의 주관적 편안함의 변화를 설문지를 통하여 분석하고, 환자의 임상 영상을 정량적 정성적 평가를 통하여 화질 변화를 분석하여 에어 매트리스의 유용성을 평가하고자 하였다. 연구에 참여한 피험자는 남성이 221명, 여성이 229명이었으며, 연령 범위는 만 18세에서 86세이다. 영상의 화질 변화를 평가하기 위해 연구 대상자 중 Chest CT & Enhancement를 촬영한 환자를 단순 무작위 표본 추출(Simple random sampling) 방법을 사용하여 정량적 평가를 위하여 각 군당 50명씩 총 150명의 환자를 선정하였으며, 정성적 평가를 위하여 각 군당 20명씩 총 60명의 환자를 선정하였다. 본 연구결과 에어 매트리스로 인하여 환자의 주관적 편안함이 증가하였으며, 임상영상의 정량적, 정성적 평가 결과 화질의 차이는 나타나지 않았다. 이상의 결과를 보았을 때 에어 매트리스는 진단 영상에 아무런 해가 없이 환자의 주관적인 편안함을 높일 수 있는 방법으로 유용하게 적용될 수 있을 것으로 사료된다.

가열장치를 구비한 부착형 X선 촬영대의 사용에 따른 화질 평가 (Evaluation of Image Quality according to the Use of Attachable X-ray Table Equipped with Heating Device)

  • 송종남;김응곤
    • 한국방사선학회논문지
    • /
    • 제9권4호
    • /
    • pp.219-225
    • /
    • 2015
  • 본 연구의 목적은 CR과 DR에서 가열장치를 구비한 부착형 탄소발열체 X선 촬영대의 사용에 따른 SNR과 CNR을 측정하여 부착 전과 부착 후의 화질을 평가하고자 한다. 알루미늄 계단 실험에서 CR은 부착 후에 SNR과 CNR이 증가하였지만 DR에서는 SNR과 CNR이 감소하였다. 인체모형팬텀 실험에서는 CR의 경우에 저에너지 저선량과 고에너지 고선량에서만 SNR과 CNR이 증가하였지만 다른 모든 조건에서는 SNR과 CNR이 감소하였다. 결론적으로 환자에게 온화한 느낌과 안전감을 제공하고 심적인 불안감을 해소하여 검사에 도움을 줄 수 있지만 임상적용에 있어서는 탄소발열체를 포함한 바닥필름과 보호필름의 두께와 재질을 고려하지 않으면 화질에 영향이 주기 때문에 향후 지속적인 연구가 필요하다고 사료된다.

전산화단층촬영장비 테이블의 에어 매트리스 적용에 따른 화질평가 (Image Quality Evaluation according to the Application of Air Mattress on Computed Tomography Equipment Table)

  • 전상원;박재윤;서태석
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.819-825
    • /
    • 2020
  • 전산화단층촬영장비 테이블로 인한 화질 저하의 경감을 위하여 개발한 에어 매트리스(Air mattress)의 유용성을 평가하고자 하였다. 5, 10 cm 두께의 에어 매트리스(Air mattress)를 개발하여 적용 유무와 두께에 따른 AAPM 팬텀을 스캔한 영상을 통하여 화질을 측정하였으며 일원배치 분산분석으로 통계적 유의성을 확인하였다. AAPM 팬텀을 표준 방식으로 스캔한 영상과 비교했을 때 에어 매트리스를 적용한 영상은 차이가 나타나지 않았으나, 에어 매트리스를 적용하지 않았을 때의 영상은 CT Number와 균일도가 낮아지고 노이즈가 높게 나타났으며 공간분해능이 낮아지는 것으로 나타났다. 개발된 에어 매트리스는 진단 영상에 아무런 해가 없을 뿐만 아니라, 화질을 높이는 데에 매우 효과적이며 최신, 고가 장비에 적용되는 기술을 이용하지 않고도 기존의 장비에 단순히 에어 매트리스를 적용함으로써 화질을 증가시킬 수 있다.

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • 제24권7호
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

CT 테이블 높이에 따른 방사선 선량 및 화질 평가 (Evaluation of Radiation Dose and Image Quality according to CT Table Height)

  • 이종웅;정홍문
    • 한국방사선학회논문지
    • /
    • 제11권6호
    • /
    • pp.453-458
    • /
    • 2017
  • 컴퓨터단층촬영 (CT:Computed Tomography)은 환자의 정확한 진단을 위해 진단참고준위인 전산화 단층촬영 선량지표 (CTDI: Computed Tomography Dose Index)와 (DLP:Dose Length Product)의 정보를 제공한다. 그러나 CT 장비가 제공하는 진단참고준위는 테이블 높이에 따른 선량의 변화를 제공하지 않는다. 이번 연구는 컴퓨터단층촬영 검사 시 최적화된 이미지와 최소선량을 찾기 위하여 컴퓨터단층촬영 테이블 높이 변화에 따른 이미지와 선량을 팬텀(PMMA: Polymethyl Methacrylate)을 사용하여 비교 평가하였다. 성인의 복부와 같은 두께인 32 cm PMMA 팬텀을 촬영할 경우 테이블 높이에 따른 선량 변화는 거의 없었다. 그러나 이미지의 노이즈(Noise) 평가에서는 테이블 높이에 따라 노이즈 변동 폭이 크게 발생되었다. 그리고 16 cm PMMA 팬텀인 경우는 노이즈의 변화는 작지만 선량변화는 약 30 % 발생하였다. 결론적으로 컴퓨터단층촬영 (CT:Computed Tomography)의 검사 시에는 환자의 두께에 중심에 정확하게 일치시켜야 한다. 또한 최적화된 이미지와 최소선량으로 검사하기 위해서는 테이블 높이 설정이 중요할 것으로 사료된다.

CT Scan Mode와 관전압 변경에 따른 소아 두부 영상의 선량 및 영상평가 (Dose and Image Evaluation of Pediatric Head Image according to CT Scan Mode and kVp Changes)

  • 김병제;김동현
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.801-808
    • /
    • 2023
  • 소아 두부 CT 검사 시 방사선 피폭 최소화와 진단적 가치가 높은 영상을 확보하기 위하여 Volume Axial Mode, High Pitch Mode, Helical Mode 간 피폭 선량과 영상의 비교 분석을 통하여 Volume Axial Mode의 유용성을 평가하였다. 1세 미만의 소아 두부 CT Helical Mode, High Pitch Mode, Volume Axial Mode에서 70, 80, 100 kVp의 관전압에 따라 영상평가와 선량평가를 시행하였다. 영상평가는 각 영상에 ROI를 설정해 SNR과 CNR을 산출하여 영상평가를 진행하였으며 일원배치 분산분석(ONE-WAY ANOVA)을 사용하여 통계적 유의성을 평가하였고, 선량평가는 검사 후 장비에서 직접 제공하는 Dose Report에 표시되는 DLP값을 이용하여 비교 분석하였다. Volume Axial Mode를 사용하여 검사하였을 때, DLP 값은 전체적으로 낮게 나왔고, SNR과 CNR은 각각 ROI와 kVp별 차이를 가졌다. Volume Axial Mode가 다른 Scan Mode와 비교하여 영상의 질을 평가하였을 때, 그 차이 값이 균일하지 않아 특정 Mode가 우수하다고 볼 수 없었으나 선량 측면에서는 가장 피폭선량을 줄일 수 있었다. 또한 Volume Axial Mode의 짧은 스캔 시간과 Table의 이동 없이 제자리에서 검사 할 수 있는 점은 방사선 감수성이 높은 1세 미만 소아 CT검사에서 유용하게 적용된다.

디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가 (Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System)

  • 김창수;강세식;고성진
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.329-335
    • /
    • 2010
  • 디지털 방사선시스템에서의 의료영상 획득의 방법은 X선을 조사하고, 반도체 디텍터(Detector)를 이용하여 직접 및 간접으로 변환하여 기존 업체마다 여러 가지 알고리즘을 적용하여 적절한 이미지 프로세싱을 거쳐서 임상의 적정한 영상을 획득한다. 방사선과에서 적절한 의료 영상 형성을 위하여 적용하는 이미지 프로세싱 파라미터(Image Processing Parameters)는 Edge, Frequency, Contrast, Latitude, LUT, Noise 등의 영상 증강의 과정은 기술력 및 업체 알고리즘에 따라 다르게 적용되고 있다. 따라서 본 논문에서는 디지털 방사선 환경에서의 최종의 임상 영상을 위한 이미지 증강의 파라미터들의 적정 세팅 값의 기준을 제시하고자 한다. 그리고 각 병원들의 의료 영상을 바탕으로 이미지 프로세싱 파라미터들을 변화하여 각 파라미터들의 세부적인 기준 세팅값을 연구하며, 실제적인 파라미터 변화에 대한 적합한 의료 영상을 디지털방사선시스템의 영상 평가 방법을 도식화하여 결과를 제시하고, 향후 임상에서 적응 및 활용 가능한 객관적인 영상 파라미터에 대한 특성 평가의 응용을 정립하고자 한다. 또한 다양한 표본 병원의 디지털 방사선 환경에서 적정 파라미터 값들을 조사하여 임상에서 영상의 화질에 미치는 영향으로 특성 평가의 객관적인 기준의 변조전달함수(MTF)의 공간해상력을 제시하고 한다.

스트리밍 비디오 화질 평가를 위한 수신 영상 복원 (Reconstruction of Transmitted Frames for Visual Quality Assessment of Streaming Video)

  • 박수경;심동규
    • 대한전자공학회논문지SP
    • /
    • 제46권1호
    • /
    • pp.32-40
    • /
    • 2009
  • 본 논문에서는 단말기상의 출력영상을 기반으로 한 수신영상 복원 방법을 제안한다. 무선 네트워크를 통해 전송되는 비디오 스트리밍의 화질을 평가하기 위해서는 단말기로 전송된 수신 영상에 대한 정보가 필요하다. 그러나 실제 전송된 스트리밍 데이터를 단말기로부터 얻기가 용이하지 않기 때문에 일반적으로 다수의 사람이 직접 화질을 평가하는 방법이 많이 사용된다. 본 논문에서는 단말기로 수신된 스트리밍 영상을 획득하기 위하여 단말기 상에서 출력되는 영상을 기반으로 전송영상을 재구성한다. 이를 위하여 제안한 방법에서는 단말기를 통해 출력되는 영상을 카메라를 이용하여 획득하고, 획득된 영상에서 나타나는 카메라와 단말기 사이의 기하학적 왜곡과 컬러 왜곡을 모델링하여 제거함으로써 전송받은 영상을 재구성하였다. 실험 결과에서는 원영상과 재구성한 영상사이의 PSNR을 측정하여 알고리즘의 성능을 평가하였다. 그 결과 제안한 알고리즘을 통해 $27{sim}28dB$의 PSNR을 얻을 수 있었다. 또한 EPSNR을 이용하여 제안한 알고리즘의 성능을 분석한 결과, 제안한 알고리즘을 통하여 예측된 영상이 MOS 테스트 스케일에서 비교적 좋은 범위에 속하는 것을 확인하였다.