• Title/Summary/Keyword: Image method

Search Result 17,776, Processing Time 0.047 seconds

Dopamine Transporter Density of the Basal Ganglia Assessed with I-123 IPT SPECT in Methamphetamine Abusers (Methamphetamine 남용자에서 I-123 IPT를 이용한 기저신경절 도파민운반체 밀도의 평가)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Kewn, Do-Hun;Sung, Young-Ok;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Lee, Sang-Woo;Yoo, Jeong-Soo;Lee, Jae-Tae;Chi, Dae-Yoon;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.481-488
    • /
    • 2005
  • Purpose: Functional imaging of dopamine transporter (DAT) defines integrity of the dopaminergic system, and DAT is the target site of drugs of abuse such as cocaine and methamphetamine. Functional imaging the DAT may be a sensitive and selective indicator of neurotoxic change by the drug. The aim of the present study is to evaluate the clinical implications of qualitative/quantitative analyses of dopamine transporter imaging in methamphetamine abusers. Materials and Methods: Six detoxified methamphetamine abusers (abuser group) and 4 volunteers (control group) were enrolled in this study. Brain MRI was performed in all of abuser group. Abuser group underwent psychiatric and depression assessment using brief psychiatric rating scale (BPRS) and Hamilton depression rating scale (HAMD), respectively. All of the subjects underwent I-123 IPT SPECT (IPT SPECT). IPT SPECT image was analysed with visual qualitative method and quantitative method using basal ganglia dopamine transporter (DAT) specific/non-specific binding ratio (SBR). Comparison of DAT SBR between abuser and control groups was performed. We also performed correlation tests between psychiatric and depression assessment results and DAT SBR in abuser group. Results: All of abuser group showed normal MRI finding, but had residual psychiatric and depressive symptoms, and psychiatric and depressive symptom scores were exactly correlated (r=1.0, p=0.005) each other. Five of them showed abnormal finding on qualitative visual I-123 IPT SPECT Abuser group had lower basal ganglia DAT SBR than that of control ($2.38{\pm}0.20\;vs\;3.04{\pm}0.27$, p=0.000). Psychiatric and depressive symptoms were negatively well correlated with basal ganglia DAT SBR (r=-0.908, p=0.012, r=-0.924, p=0.009). Conclusion: These results suggest that dopamine transporter imaging using I-123 IPT SPECT may be used to evaluate dopaminergic system of the basal ganglia and the clinical status in methamphetamine abusers.

A Study on the Critical Success Factors of Social Commerce through the Analysis of the Perception Gap between the Service Providers and the Users: Focused on Ticket Monster in Korea (서비스제공자와 사용자의 인식차이 분석을 통한 소셜커머스 핵심성공요인에 대한 연구: 한국의 티켓몬스터 중심으로)

  • Kim, Il Jung;Lee, Dae Chul;Lim, Gyoo Gun
    • Asia pacific journal of information systems
    • /
    • v.24 no.2
    • /
    • pp.211-232
    • /
    • 2014
  • Recently, there is a growing interest toward social commerce using SNS(Social Networking Service), and the size of its market is also expanding due to popularization of smart phones, tablet PCs and other smart devices. Accordingly, various studies have been attempted but it is shown that most of the previous studies have been conducted from perspectives of the users. The purpose of this study is to derive user-centered CSF(Critical Success Factor) of social commerce from the previous studies and analyze the CSF perception gap between social commerce service providers and users. The CSF perception gap between two groups shows that there is a difference between ideal images the service providers hope for and the actual image the service users have on social commerce companies. This study provides effective improvement directions for social commerce companies by presenting current business problems and its solution plans. For this, This study selected Korea's representative social commerce business Ticket Monster, which is dominant in sales and staff size together with its excellent funding power through M&A by stock exchange with the US social commerce business Living Social with Amazon.com as a shareholder in August, 2011, as a target group of social commerce service provider. we have gathered questionnaires from both service providers and the users from October 22, 2012 until October 31, 2012 to conduct an empirical analysis. We surveyed 160 service providers of Ticket Monster We also surveyed 160 social commerce users who have experienced in using Ticket Monster service. Out of 320 surveys, 20 questionaries which were unfit or undependable were discarded. Consequently the remaining 300(service provider 150, user 150)were used for this empirical study. The statistics were analyzed using SPSS 12.0. Implications of the empirical analysis result of this study are as follows: First of all, There are order differences in the importance of social commerce CSF between two groups. While service providers regard Price Economic as the most important CSF influencing purchasing intention, the users regard 'Trust' as the most important CSF influencing purchasing intention. This means that the service providers have to utilize the unique strong point of social commerce which make the customers be trusted rathe than just focusing on selling product at a discounted price. It means that service Providers need to enhance effective communication skills by using SNS and play a vital role as a trusted adviser who provides curation services and explains the value of products through information filtering. Also, they need to pay attention to preventing consumer damages from deceptive and false advertising. service providers have to create the detailed reward system in case of a consumer damages caused by above problems. It can make strong ties with customers. Second, both service providers and users tend to consider that social commerce CSF influencing purchasing intention are Price Economic, Utility, Trust, and Word of Mouth Effect. Accordingly, it can be learned that users are expecting the benefit from the aspect of prices and economy when using social commerce, and service providers should be able to suggest the individualized discount benefit through diverse methods using social network service. Looking into it from the aspect of usefulness, service providers are required to get users to be cognizant of time-saving, efficiency, and convenience when they are using social commerce. Therefore, it is necessary to increase the usefulness of social commerce through the introduction of a new management strategy, such as intensification of search engine of the Website, facilitation in payment through shopping basket, and package distribution. Trust, as mentioned before, is the most important variable in consumers' mind, so it should definitely be managed for sustainable management. If the trust in social commerce should fall due to consumers' damage case due to false and puffery advertising forgeries, it could have a negative influence on the image of the social commerce industry in general. Instead of advertising with famous celebrities and using a bombastic amount of money on marketing expenses, the social commerce industry should be able to use the word of mouth effect between users by making use of the social network service, the major marketing method of initial social commerce. The word of mouth effect occurring from consumers' spontaneous self-marketer's duty performance can bring not only reduction effect in advertising cost to a service provider but it can also prepare the basis of discounted price suggestion to consumers; in this context, the word of mouth effect should be managed as the CSF of social commerce. Third, Trade safety was not derived as one of the CSF. Recently, with e-commerce like social commerce and Internet shopping increasing in a variety of methods, the importance of trade safety on the Internet also increases, but in this study result, trade safety wasn't evaluated as CSF of social commerce by both groups. This study judges that it's because both service provider groups and user group are perceiving that there is a reliable PG(Payment Gateway) which acts for e-payment of Internet transaction. Accordingly, it is understood that both two groups feel that social commerce can have a corporate identity by website and differentiation in products and services in sales, but don't feel a big difference by business in case of e-payment system. In other words, trade safety should be perceived as natural, basic universal service. Fourth, it's necessary that service providers should intensify the communication with users by making use of social network service which is the major marketing method of social commerce and should be able to use the word of mouth effect between users. The word of mouth effect occurring from consumers' spontaneous self- marketer's duty performance can bring not only reduction effect in advertising cost to a service provider but it can also prepare the basis of discounted price suggestion to consumers. in this context, it is judged that the word of mouth effect should be managed as CSF of social commerce. In this paper, the characteristics of social commerce are limited as five independent variables, however, if an additional study is proceeded with more various independent variables, more in-depth study results will be derived. In addition, this research targets social commerce service providers and the users, however, in the consideration of the fact that social commerce is a two-sided market, drawing CSF through an analysis of perception gap between social commerce service providers and its advertisement clients would be worth to be dealt with in a follow-up study.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF

A Methodology of Customer Churn Prediction based on Two-Dimensional Loyalty Segmentation (이차원 고객충성도 세그먼트 기반의 고객이탈예측 방법론)

  • Kim, Hyung Su;Hong, Seung Woo
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.4
    • /
    • pp.111-126
    • /
    • 2020
  • Most industries have recently become aware of the importance of customer lifetime value as they are exposed to a competitive environment. As a result, preventing customers from churn is becoming a more important business issue than securing new customers. This is because maintaining churn customers is far more economical than securing new customers, and in fact, the acquisition cost of new customers is known to be five to six times higher than the maintenance cost of churn customers. Also, Companies that effectively prevent customer churn and improve customer retention rates are known to have a positive effect on not only increasing the company's profitability but also improving its brand image by improving customer satisfaction. Predicting customer churn, which had been conducted as a sub-research area for CRM, has recently become more important as a big data-based performance marketing theme due to the development of business machine learning technology. Until now, research on customer churn prediction has been carried out actively in such sectors as the mobile telecommunication industry, the financial industry, the distribution industry, and the game industry, which are highly competitive and urgent to manage churn. In addition, These churn prediction studies were focused on improving the performance of the churn prediction model itself, such as simply comparing the performance of various models, exploring features that are effective in forecasting departures, or developing new ensemble techniques, and were limited in terms of practical utilization because most studies considered the entire customer group as a group and developed a predictive model. As such, the main purpose of the existing related research was to improve the performance of the predictive model itself, and there was a relatively lack of research to improve the overall customer churn prediction process. In fact, customers in the business have different behavior characteristics due to heterogeneous transaction patterns, and the resulting churn rate is different, so it is unreasonable to assume the entire customer as a single customer group. Therefore, it is desirable to segment customers according to customer classification criteria, such as loyalty, and to operate an appropriate churn prediction model individually, in order to carry out effective customer churn predictions in heterogeneous industries. Of course, in some studies, there are studies in which customers are subdivided using clustering techniques and applied a churn prediction model for individual customer groups. Although this process of predicting churn can produce better predictions than a single predict model for the entire customer population, there is still room for improvement in that clustering is a mechanical, exploratory grouping technique that calculates distances based on inputs and does not reflect the strategic intent of an entity such as loyalties. This study proposes a segment-based customer departure prediction process (CCP/2DL: Customer Churn Prediction based on Two-Dimensional Loyalty segmentation) based on two-dimensional customer loyalty, assuming that successful customer churn management can be better done through improvements in the overall process than through the performance of the model itself. CCP/2DL is a series of churn prediction processes that segment two-way, quantitative and qualitative loyalty-based customer, conduct secondary grouping of customer segments according to churn patterns, and then independently apply heterogeneous churn prediction models for each churn pattern group. Performance comparisons were performed with the most commonly applied the General churn prediction process and the Clustering-based churn prediction process to assess the relative excellence of the proposed churn prediction process. The General churn prediction process used in this study refers to the process of predicting a single group of customers simply intended to be predicted as a machine learning model, using the most commonly used churn predicting method. And the Clustering-based churn prediction process is a method of first using clustering techniques to segment customers and implement a churn prediction model for each individual group. In cooperation with a global NGO, the proposed CCP/2DL performance showed better performance than other methodologies for predicting churn. This churn prediction process is not only effective in predicting churn, but can also be a strategic basis for obtaining a variety of customer observations and carrying out other related performance marketing activities.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

Stage Costume Design for Performance Hamlet (II) - The Study on Pattern and Manufactured Product - (햄릿 공연을 위한 무대의상 디자인 (II) - 패턴 및 실물제작 -)

  • Kim, Soon-Ku;Hwang, Seong-Won
    • Fashion & Textile Research Journal
    • /
    • v.6 no.1
    • /
    • pp.41-50
    • /
    • 2004
  • This research proposes the on-stage costumes for the play Hamlet of Shakespeare performed by Yunheedan Guhri Pae - the Street Theater Troupe. Stage costumes have an important role in displaying the characteristics of each characters to the audience and has big visual effects. However, in order to design the costumes in the object viewpoints of the audience, the survey on the images of the characters who had actually watched the performance was taken place and proposed the costume design according to the results of the survey. Hamlet a: This result was applied to propose a sweater in black color, black leather pants and vest. Hamlet b: This result was applied to propose hooded coat in purple in middle level of brightness and color spectrum and yellow coat. For free image, loose pants in blue and vest in the same color tone were proposed. Gertrude a: This result was applied to use purple (violet) with reddish tone to propose the formation of a dress applying tailored suit. Gertrude b: This result was applied to propose purple gown and the one-piece dress with black laces. Ophelia a: This result was applied to propose feminine white dress and cape in purple color tone. Ophelia b: This result was applied to propose dyed and weaved clothes. Through the surveys as above, the images of each character was driven in adjectives, and using the results driven from the brightness, coloration, and color, color images were proposed. Only one costume cannot make up for the stage costumes and because it exists as an element of stage production, it is true that costumes are limited in some areas. However, that limit can become the motive of the costume. There is a limit, which the designer cannot produce the costumes as he or she had designed but I believe it is the center of the on-stage customers to display the characteristics of the characters according to the given concept. The limit of this research is the fact that because the costumes were designed so they fit the conditions already given, thus it was difficult to regard the process of designing and producing the costume as a project done according to the interaction. And in the future, if it is possible, I wish for the joint research with the people responsible for stage art to take place as a practical stage art. It was possible to produce practical costume since they were produced for actual performance and the production of costumes considering the dance steps, line of flow, and acting, was able to reduce the trial and error on stage. Through this research, I felt that the understanding and smooth interaction on diverse other areas not limited to the costume design should be taken place and believe that this was a research that proposes new research method since there had been only a few previous research regarding the on-stage costumes for actual performances. Therefore, this research had depended on the surveys given to the audiences to endow objectivity, however, I wish this research can contribute to defining effective process and methods for the on-stage costumes with more active researches with diverse methods and in diverse areas. I am sorry that the costume production for all the characters and all the scenes in Hamlet couldn't be done due to many limitations. As the following research assignment, I am planning on designing the costumes for all the scenes.

A Study on the Variable Factors for Brain Perfusion SPECT(Diamox) Scan (Brain Perfusion SPECT(Diamox) 검사의 수행결과에 영향을 주는 요인)

  • Lee, Jin-Hyeong;Kim, Sang-Eon;Park, Hyeon-Soo;Park, Yeoung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.99-103
    • /
    • 2011
  • Purpose: Head movement during brain perfusion SPECT (Diamox) scan is a one of important issues which decreases image quality. It also causes repeated scans. This study was designed to evaluate variable factors causing scan failures. Materials and Methods: 676 patients (359 men, 317 women, age average $54.5{\pm}18.4$) for brain perfusion SPECT (Diamox) scan from March, 2010 to Feb. 2011 were used as a subject. Age data and the kind of disease(Moyamoya disease (MMD), None moyamoya disease (NMMD), Cerebral infarction (CI)), test performance outcome (success,failure) were collected. The head movement factors(gender, disease, age, head fixation device) were evaluated by chi-square test and logistic regression analysis Results: The result showed that men had higher scan failure rate than women. Seniors in seventies(men 3.4%, women 1.5%) showed the most highest failure rate. Using head fixation device increased scan success rate up to 94.4~97.7%. The scan success rate is dependent upon gender, head fixation device by chi-square test(${\chi}^2$=3.8 (df=1, p<0.05), ${\chi}^2$=10.4 (df=1, p<0.001)) Gender, disease(CI), head fixation device showed very effective result in logistic regression analysis.(Wald=3.3 (p<0.07), Wald=3.7 (p<0.05), Wald=9.3 (p<0.05) Conclusion: It is demonstrated that gender, disease, using head fixation device is statistically very useful factors. Especially, head fixation device is a main key minimizing repeated scan.

  • PDF

Land-Cover Change Detection of Western DMZ and Vicinity using Spectral Mixture Analysis of Landsat Imagery (선형분광혼합화소분석을 이용한 서부지역 DMZ의 토지피복 변화 탐지)

  • Kim, Sang-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.1
    • /
    • pp.158-167
    • /
    • 2006
  • The object of this study is to detect of land-cover change in western DMZ and vicinity. This was performed as a basic study to construct a decision support system for the conservation or a sustainable development of the DMZ and Vicinity near future. DMZ is an is 4km wide and 250km long and it's one of the most highly fortified boundaries in the world and also a unique thin green line. Environmentalists want to declare the DMZ as a natural reserve and a biodiversity zone, but nowadays through the strengthening of the inter-Korean economic cooperation, some developers are trying to construct a new-town or an industrial complex inside of the DMZ. This study investigates the current environmental conditions, especially deforestation of the western DMZ adopting remote sensing and GIS techniques. The Land-covers were identified through the linear spectvral mixture analysis(LSMA) which was used to handle the spectral mixture problem of low spatial resolution imagery of Landsat TM and ETM+ imagery. To analyze quantitative and spatial change of vegetation-cover in western DMZ, GIS overlay method was used. In LSMA, to develop high-quality fraction images, three endmembers of green vegetation(GV), soil, water were driven from pure features in the imagery. Through 15 years, from 1987 to 2002, forest of western DMZ and vicinity was devastated and changed to urban, farmland or barren land. Northern part of western DMZ and vicinity was more deforested than that of southern part. ($52.37km^2$ of North Korean forest and $39.04km^2$ of South Korean were change to other land-covers.) In case of North Korean part, forest changed to barren land and farmland and in South Korean part, forest changed to farmland and urban area. Especially, In North Korean part of DMZ and vicinity, $56.15km^2$ of farmland changed to barren land through 15 years, which showed the failure of the 'Darakbat' (terrace filed) project which is one of food increase projects in North Korea.

  • PDF