• Title/Summary/Keyword: Image display system

Search Result 792, Processing Time 0.025 seconds

Computer Image Processing for AR Conceptional Display 3D Navigational Information (증강현실 개념의 항행정보 가시화를 위한 영상처리 기술)

  • Lee, Jung-Min;Lee, Kyung-Ho;Kim, Dae-Soek;Nam, Byeong-Wook
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.10a
    • /
    • pp.245-246
    • /
    • 2014
  • This paper suggests the navigation information display system which is based on augmented reality technology and especially focuses on image analysis technology. Navigator has to always confirm the information from marine electronic navigation devices and then they compare with the view of outside targets of the windows. During this 'head down' posture, they feel uncomfortable and sometimes it cause near-accidents such as collision or missing objects, because he or she cannot keep an eye on the front view of windows. Augmented reality can display both of information of virtual and real in a single display. Therefore we tried to adapt the AR technology to help navigators and have been studied and developed image pre-processing module as a previous research already. To analysis the outside view of the bridge window, we have extracted navigational information from the camera image by using image processing. This paper mainly describes about recognizing ship feature by haar-like feature and filtering region of interest area by AIS data, which are to improve accuracy of the image analysis.

  • PDF

A Study on Formation of Incremental Palette for Lower Quality Display (저 사양 디스플레이를 위한 동적 팔래트 생성 방법에 관한 연구)

  • Paik, Doo-Won;Lim, Hun-Gyu;Hwang, Joo-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.1
    • /
    • pp.169-173
    • /
    • 2008
  • A navigation system for virtual environments using low-quality HMD(head mounted display) must quantize images when the system presents true-color image with restricted number of colors. Such navigation system quantizes an image by using fixed palette. If the system represents an image by using a variable palette which is made considering a region around the viewpoint then user can perceive a virtual environments more vividly because human visual system is sensitive to the colors variation in the region around the viewpoint. In this paper we propose a color quantization algorithm that quantize a region around the viewpoint more finely than other regions at each variation of viewpoint for virtual environments navigation system.

  • PDF

Image Enhancement of an Infrared Thermal Camera Using Edge Detection Methods (에지 검출 방법을 이용한 열화상 카메라의 영상 개선)

  • Jung, Min Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2016
  • This paper proposes a new image enhancement method for an infrared thermal image. The proposed method uses both Laplacian and Prewitt edge detectors. Without a visible light, it uses an infrared image for the edge detection. The method subtracts contour images from the infrared thermal image. It results black contours of objects in the infrared thermal image. That makes the objects in the infrared thermal image distinguished clearly. The proposed method is implemented using C language in an embedded Linux system for a high-speed real-time image processing. Experiments were conducted by using various infrared thermal images. The results show that the proposed method is successful for image enhancement of an infrared thermal image.

Optical System Design of Compact Head-Up Display(HUD) using Micro Display (마이크로 디스플레이를 이용한 소형 헤드업 디스플레이 광학계 설계)

  • Han, Dong-Jin;Kim, Hyun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6227-6235
    • /
    • 2015
  • The HUD has recently been downsized due to the development of micro display and LED technology as a see through information display device, gradually expands the application areas. In this paper, using a DLP micro display device designed a compact head-up display(HUD) optical system for biocular observation of the image exhibition area 5 inches. It was analyzed for each design element of the optical system in order to design a compacted HUD. DLP, projection optical system and concave image combiner were discussed the design approach and the characteristics. Through a connection structure analysis of each optical system, detailed design specifications were set up and designed the optical system in detail. Put a folded configuration in the form of a white diffuse reflector between the projection lens and concave image combiner was designed to be independent, respectively. Distance of the projected image is adjustable up to approximately 2m ~ infinity and observation distance is 1m. Resolution could be recognized by 1 ~ 2pixels in HD($1,280{\times}720pixels$) class, various characters and symbols could be read. In addition, color navigation map, daytime video camera and thermal imaging cameras can be displayed.

Dynamic Stitching Algorithm for 4-channel Surround View System using SIFT Features (SIFT 특징점을 이용한 4채널 서라운드 시스템의 동적 영상 정합 알고리즘)

  • Joongjin Kook;Daewoong Kang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.1
    • /
    • pp.56-60
    • /
    • 2024
  • In this paper, we propose a SIFT feature-based dynamic stitching algorithm for image calibration and correction of a 360-degree surround view system. The existing surround view system requires a lot of processing time and money because in the process of image calibration and correction. The traditional marker patterns are placed around the vehicle and correction is performed manually. Therefore, in this study, images captured with four fisheye cameras mounted on the surround view system were distorted and then matched with the same feature points in adjacent images through SIFT-based feature point extraction to enable image stitching without a fixed marker pattern.

  • PDF

A Study on the Development of a MPACS (시범 MPAC 시스템 개발에 관한 연구)

  • 김근섭;임호근
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.215-222
    • /
    • 1991
  • In this paper, we present a result of our study on how to construct a pilot MPACS (medical hic lure archiving and communication System) based on X -Window system. The proposed MPACS Is composed of image acquisition units, image archiving and processing units, display units, and all units are Interfaced with a LAN The image management is done according to the TIFF (Tagged Image File Format) , and the dis- play system is built upon generally accepted software packages, namely the X -Window system. Also, lossless and lossy digital image compression methods were implemented and tested with X -ray and CT images.

  • PDF

Lens system design for head mounted display using schematic eyes (정밀모형안을 이용한 Head Mounted Display용 렌즈계 설계)

  • 박성찬;안현경
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.236-243
    • /
    • 2003
  • We discussed the design of lens module schematic eyes equivalent to finite model eyes, which are used to model the human eye based on spherical aberration and Stiles-Crowford effect. The optical system for head mounted display (HMD) is designed and evaluated using lens module schematic eyes. In addition to a compact HMD system, an optical system with high Performance is required. To satisfy these requirements, we used diffractive optical elements and aspheric surfaces so that the color and mono-chromatic aberrations were corrected. The optical system for HMD is composed of 0.47 inch micro-display of SVGA grade with 480,000 pixels, a plastic hybrid lens for the virtual image, and the lens module schematic eyes. The designed optical system fulfills the current specifications of HMD: such as, EFL of 31.25 mm, FOV of 24H$\times$18V$\times$30D degrees, and overall length of 59.1 mm. As a result, we could design an optical system useful for HMD; the system is expected to be comfortable while the user wears it.

Study on the Real Time Medical Image Processing (실시간 의학 영상 처리에 관한 연구)

  • 유선국;이건기
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.118-122
    • /
    • 1987
  • The medical image processing system is intended for a diverse set of users in the medical Imaging Parts. This system consists of a 640 Kbyte IBM-PC/AT with 30 Mbyte hard disk, special purpose image processor with video input devices and display monitor. Image may be recorded and processed in real time at sampling rate up to 10 MHz. This system provides a wide range of image enhancement processing facilities via a menu-driven software packages. These facilities include point by point processing, image averaging, convolution filter and subtraction.

  • PDF

Color Inspection System for Plasma Display Panel by Using Area Camera (영역 카메라를 이용한 플라즈마 디스플레이의 컬러출력 검사 시스템)

  • 김우섭;도현철;진성일
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.1763-1766
    • /
    • 2003
  • This paper proposes a non-contact color inspection system for plasma display panel (PDP). The red, green, and blue test pattern images are acquired by using the area color CCD camera at the various distance from the PDP. The RGB values are obtained from the region of interest (ROI) which are extracted by applying the image processing to the test pattern image. Finally, the CIE xy and u'v' chromaticity coordinates of the test pattern images according to the distance are acquired from the RGB color coordinates.

  • PDF

A Study on the Measurement of Surface-strain Using the Image Processing Technique(II) (화상처리법을 이용한 곡면변형률 측정에 관한 연구(II))

  • 한상준;김영수;김형종;오수익
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.10a
    • /
    • pp.142-146
    • /
    • 1997
  • An automated surface-strain measuring system is developed in the present study, which consists of the hardware to capture and to display digital images and the software to calculate the 3-D informations of grid points. The software is implemented using the image processing technique, and includes a program for the camera calibration and the post-processor to display the strain distribution. An LDH(limitting dome height) test specimen is measured its surface-strain as an application of the present system.

  • PDF