• Title/Summary/Keyword: Image Sensor Module

Search Result 133, Processing Time 0.033 seconds

Auto Exposure Control System using Variable Time Constants (가변 시상수를 이용한 자동 노출제어 시스템)

  • Kim, Hyun-Sik;Lee, Sung-Mok;Jang, Won-Woo;Ha, Joo-Young;Kim, Joo-Hyun;Kang, Bong-Soon;Lee, Gi-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2007
  • In order to obtain a fine picture, a camera has many convenient functions. Its representative functions are Auto Focus(AF), Auto White Balance(AWB) and Auto Exposure(AE). In this paper, we present the new algorithm of Auto Exposure control system, one of its useful functions The proposed algorithm of Auto Exposure control system is based on IIR Filter with Variable Time Constant. First, in order to establish the standards of exposure control, we compare change of the picture luminance with luminance of an object in the Zone system. Second, we make an ideal characteristic graph of luminance by using the results. Finally, we can find the value of the right exposure by comparing an ideal characteristic graph of the luminance with the value of the current expose of a scene. We can find an appropriate exposure as comparing the ideal characteristic graph of the luminance with current exposure of a scene. In order to find a suitable exposure state, we make use of IIR Filter instead of a conventional method using micro-controller. In this paper, the proposed system has therefore simple structure, we use it for compact image sensor module used in the handheld device.

Design of Readout Circuit with Dual Slope Correction for photo sensor of LTPS TFT-LCD (LTPS TFT LCD 패널의 광 센서를 위한 dual slope 보정 회로)

  • Woo, Doo-Hyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.6
    • /
    • pp.31-38
    • /
    • 2009
  • To improve the image quality and lower the power consumption of the mobile applications, it is the one of the best candidate to control the backlight unit of the LCD module with ambient light. Ambient light sensor and readout circuit were integrated in LCD panel for the mobile applications, and we designed them with LTPS TFT. We proposed noble start-up correction in order to correct the variation of the photo sensors in each panel. We used time-to-digital method for converting photo current to digital data. To effectively merge time-to-digital method with start-up correction, we proposed noble dual slope correction method. The entire readout circuit was designed and estimated with LTPS TFT process. The readout circuit has very simple and stable structure and timing, so it is suitable for LTPS TFT process. The readout circuit can correct the variation of the photo sensors without an additional equipment, and it outputs the 4-levels digital data per decade for input luminance that has a dynamic range of 60dB. The readout rate is 100 times/sec, and the linearity error for digital conversion is less than 18%.

The Design of Smart-phone Application Design for Intelligent Personalized Service in Exhibition Space (전시 공간에서 지능형 개인화 서비스를 위한 스마트 폰 어플리케이션 설계)

  • Cho, Young-Hee;Choi, Ae-Kwon
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • The exhibition industry, as technology-intensive, eco-friendly industry, contributes to regional and national development and enhancement of its image as well, if it joins cultural and tourist industry. Therefore, We need to revitalize the exhibition industry, as actively holding an exhibition event. However, to attract a number of exhibition audience, the work of enhancing audience satisfaction and awareness of value for participation should be prioritized after improving quality of service within exhibition hall. As one way to enhance the quality of service, it is thought that the way providing personalized service geared toward each audience is needed. that is, if audience avoids the complexity in exhibition space and it affords them service to enable effective time and space management, it will improve the satisfaction. All such personalized service affordable lets the audience's preference on the basis of each audience profile registered in advance online grasp. and Based on this information, it is provided with exhibition-related information suited their purpose that is the booth for the interesting audience, the shortest path to go to the booth and event via audience's smart phone. and it collects audience's reaction information, such as visiting the booth, participating the event through offered the information in this way and location information for the flow of movement, the present position so that it makes revision of existing each audience profile. After correcting the information, it extracts the individual's preference. hereunder, it provides recommend booth and event information. in other words, it provides optimal information for individual by amendment based on reaction information about recommending information built on basic profile. It provides personalized service dynamic and interactive with audience. This paper will be able to provide the most suitable information for each audience through circular and interactive structure and designed smart-phone application supportable for updating dynamic and interactive personalized service that is able to afford surrounding information in real time, as locating movement position through sensing. The proposed application collects user‘s context information and carrys information gathering function collecting the reaction about searched or provided information via sensing. and it also carrys information gathering function providing needed data for user in exhibition hall. In other words, it offers information about recommend booth of position foundation for user, location-based services of recommend booth and involves service providing detailed information for inside exhibition by using service of augmented reality, the map of whole exhibition as well. and it is also provided with SNS service that is able to keep information exchange besides intimacy. To provide this service, application is consisted of several module. first of all, it includes UNS identity module for sensing, and contain sensor information gathering module handling and collecting the perceived information through this module. Sensor information gathered like this transmits the information gathering server. and there is exhibition information interfacing with user and this module transmits to interesting information collection module through user's reaction besides interface. Interesting information collection module transmits collected information and If valid information out of the information gathering server that brings together sensing information and interesting information is sent to recommend server, the recommend server makes recommend information through inference with gathered valid information. If this server transmit by exhibition information process, exhibition information process module is provided with user by interface. Through this system it raises the dynamic, intelligent personalized service for user.

Development of Packaging Technology for CdTe Multi-Energy X-ray Image Sensor (CdTe 멀티에너지 엑스선 영상센서 패키징 기술 개발)

  • Kwon, Youngman;Kim, Youngjo;Ryu, Cheolwoo;Son, Hyunhwa;Kim, Byoungwook;Kim, YoungJu;Choi, ByoungJung;Lee, YoungChoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.371-376
    • /
    • 2014
  • The process of flip-chip bump bonding, Au wire bonding and encapsulation were sucessfully developed and modularized. The CdTe sensor and ROIC were optimally jointed together at $150^{\circ}C$ and $270^{\circ}C$ respectively under24.5 N for 30s. To make SnAg bump on ROIC easy to be bonded, the higher bonding temperature was established than CdTe sensor's. In addition, the bonding pressure was lowered minimally because CdTe Sensor is easier to break than Si Sensor. CdTe multi-energy sensor module observed were no electrical failures in the joints using developed flip chip bump bonding and Au wire bonding process. As a result of measurement, shearing force was $2.45kgf/mm^2$ and, it is enough bonding force against threshold force, $2kgf/mm^2s$.

A Robust Depth Map Upsampling Against Camera Calibration Errors (카메라 보정 오류에 강건한 깊이맵 업샘플링 기술)

  • Kim, Jae-Kwang;Lee, Jae-Ho;Kim, Chang-Ick
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.6
    • /
    • pp.8-17
    • /
    • 2011
  • Recently, fusion camera systems that consist of depth sensors and color cameras have been widely developed with the advent of a new type of sensor, time-of-flight (TOF) depth sensor. The physical limitation of depth sensors usually generates low resolution images compared to corresponding color images. Therefore, the pre-processing module, such as camera calibration, three dimensional warping, and hole filling, is necessary to generate the high resolution depth map that is placed in the image plane of the color image. However, the result of the pre-processing step is usually inaccurate due to errors from the camera calibration and the depth measurement. Therefore, in this paper, we present a depth map upsampling method robust these errors. First, the confidence of the measured depth value is estimated by the interrelation between the color image and the pre-upsampled depth map. Then, the detailed depth map can be generated by the modified kernel regression method which exclude depth values having low confidence. Our proposed algorithm guarantees the high quality result in the presence of the camera calibration errors. Experimental comparison with other data fusion techniques shows the superiority of our proposed method.

Design of UWB/WiFi Module based Wireless Transmission for Endoscopic Camera (UWB/WiFi 모듈 기반의 내시경 카메라용 무선전송 설계)

  • Shim, Dongha;Lee, Jaegon;Yi, Jaeson;Cha, Jaesang;Kang, Mingoo
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Ultra-wide-angle wireless endoscopes are demonstrated in this paper. The endoscope is composed of an ultra-wide-angle camera module and wireless transmission module. A lens unit with the ultra-wide FOV of 162 degrees is designed and manufactured. The lens, image sensor, and camera processor unit are packaged together in a $3{\times}3{\times}9-cm3$ case. The wireless transmission modules are implemented based on UWB- and WiFi-based platform, respectively. The UWB-based module can transmit HD video to a computer in resolution of $2048{\times}1536$ (QXGA) and the frame rate of 15 fps in MJPEG compression mode. The maximum data transfer rate reaches 41.2 Mbps. The FOV and the resolution of the endoscope is comparable to a medical-grade endoscope. The FOV and resolution is ~3X and 16X higher than that of a commercial high-performance WiFi endoscope, respectively. The WiFi-based module streams out video to a smart device with th maximum date transfer rate of 1.5 Mbps at the resolution of $640{\times}480$ (VGA) and the frame rate of 30 fps in MJPEG compression mode. The implemented components show the feasibility of cheap medical-grade wireless electronic endoscopes, which can be effectively used in u-healthcare, emergency treatment, home-healthcare, remote diagnosis, etc.

Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources (감마선원의 공간분포 가시화 및 3D모델링을 위한 운용환경 개발)

  • Song, Keun-Young;Lim, Ji-Seok;Choi, Jung-Huk;Yuk, Young-Ho;Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.702-704
    • /
    • 2017
  • In case of dismantling of nuclear power generation facility or radiation accident, the accurate information of gammaray source is essential for rapid decontamination. In order to more efficiently represent the position of the gamma ray to be removed, we create a spatial domain based on the real image. And we can perform decontamination of gamma-ray source more quickly by expressing the distribution of radiation source. The developed gamma ray imaging device overlaps with the visible image after gamma - ray detection and provides only two - dimensional image, but it does not show the distance information to the source. In this paper, we have developed a operation environment using the 3D visualization model for reporting effective decontamination operation.

  • PDF

A LiDAR-based Visual Sensor System for Automatic Mooring of a Ship (선박 자동계류를 위한 LiDAR기반 시각센서 시스템 개발)

  • Kim, Jin-Man;Nam, Taek-Kun;Kim, Heon-Hui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1036-1043
    • /
    • 2022
  • This paper discusses about the development of a visual sensor that can be installed in an automatic mooring device to detect the berthing condition of a vessel. Despite controlling the ship's speed and confirming its location to prevent accidents while berthing a vessel, ship collision occurs at the pier every year, causing great economic and environmental damage. Therefore, it is important to develop a visual system that can quickly obtain the information on the speed and location of the vessel to ensure safety of the berthing vessel. In this study, a visual sensor was developed to observe a ship through an image while berthing, and to properly check the ship's status according to the surrounding environment. To obtain the adequacy of the visual sensor to be developed, the sensor characteristics were analyzed in terms of information provided from the existing sensors, that is, detection range, real-timeness, accuracy, and precision. Based on these analysis data, we developed a 3D visual module that can acquire information on objects in real time by conducting conceptual designs of LiDAR (Light Detection And Ranging) type 3D visual system, driving mechanism, and position and force controller for motion tilting system. Finally, performance evaluation of the control system and scan speed test were executed, and the effectiveness of the developed system was confirmed through experiments.

Study on Structure Visual Inspection Technology using Drones and Image Analysis Techniques (드론과 이미지 분석기법을 활용한 구조물 외관점검 기술 연구)

  • Kim, Jong-Woo;Jung, Young-Woo;Rhim, Hong-Chul
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.6
    • /
    • pp.545-557
    • /
    • 2017
  • The study is about the efficient alternative to concrete surface in the field of visual inspection technology for deteriorated infrastructure. By combining industrial drones and deep learning based image analysis techniques with traditional visual inspection and research, we tried to reduce manpowers, time requirements and costs, and to overcome the height and dome structures. On board device mounted on drones is consisting of a high resolution camera for detecting cracks of more than 0.3 mm, a lidar sensor and a embeded image processor module. It was mounted on an industrial drones, took sample images of damage from the site specimen through automatic flight navigation. In addition, the damege parts of the site specimen was used to measure not only the width and length of cracks but white rust also, and tried up compare them with the final image analysis detected results. Using the image analysis techniques, the damages of 54ea sample images were analyzed by the segmentation - feature extraction - decision making process, and extracted the analysis parameters using supervised mode of the deep learning platform. The image analysis of newly added non-supervised 60ea image samples was performed based on the extracted parameters. The result presented in 90.5 % of the damage detection rate.

Technical Characteristics and Trends of Capsule Endoscope (캡슐 내시경의 기술적 특징과 동향)

  • Kim, Ki-Yun;Won, Kyung-Hoon;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.329-337
    • /
    • 2012
  • Capsule Endoscope(CE) is a capsule-shaped electronic device which can examine the lesions in digestive tract of human body. Recently the medical procedure using capsule endoscope is receiving great attention to both doctors and patients, since the conventional push-typed endoscope using cables brings great pain and fear to the patients. The technique was firstly available in 2000 and is based on a convergence techniques among BT(Bio Technology), IT(Information Technology), and NT(Nano Technology). The device consists of an optical parts including LEDs(Light Emitting Diodes), an image sensor, a communication module and a power module. Capsule endoscope is the embodiment of the state-of-the art technology and requires key technologies in the various engineering fields. Therefore, in this paper, we introduce the composition of the capsule endoscope system, and compare the communication method between RF(Radio Frequency) communication and HBC(Human Body Communication), which are typically used for data transmission in the capsule endoscope. Furthermore, we analyze the specification of commercialized capsule endoscopes and present the future developments and technical challenges.