• 제목/요약/키워드: Image Impedance

Search Result 110, Processing Time 0.021 seconds

Impedance Tomography using Internal Current Density Distribution Measured by Nuclear Magnetic Resonance (자기공명촬영상에서 구한 내부 전류밀도를 이용한 임피던스 단층촬영법)

  • Lee, Su-Yeol;U, Eung-Je;Mun, Chi-Ung
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.413-418
    • /
    • 1994
  • In electrical impedance tomography (EIT), we use boundary current and voltage measurements to provide the information about the cross-sectional distribution of electrical impedance or resistivity One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.7T NMR machine. We implemented a resistivity image reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the image reconstruction algorithm and furture direction of the research.

  • PDF

The Impedance Characteristics of Verical Antennas Over a Finite Image Plane (영상면상의 직선형 안테나의 임피이던스 특성)

  • 양인용;조성호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.3
    • /
    • pp.2-13
    • /
    • 1966
  • The impedance characteristics of vertical antennas over a finite image plane were analyzed and measured. Two kinds of image plane, one rectangular and the other circular, were used for the mesurements. And the length of antennas was varied at fixed frequency. All kinds of terminal zone effects which possible raise questions because of antenna mounting system were discussed. It is observed from the results that the measured impedance of antennas over a comparativley large rectangular plane is approximatly identical with the theoretical value, and also the impedance of antennas over a comparatively small circular plane had similar characteristics to a comparatively thick antennas over an inifinite image plane.

  • PDF

Effect of input current patterns on dynamic electrical impedance imaging of two-phase flows (이상유동의 동적 전기 임피던스 가시화에 대한 전류패턴의 영향)

  • Chung, Soon-Il;ljaz, U.Z.;Khambampati, A.K.;Kim, Sin;Kim, Kyung-Youn;Kim, Min-Chan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.475-478
    • /
    • 2006
  • In electrical impedance tomography (EIT) an array of electrodes is attached on the boundary of an object and small alternating currents are injected through these electrodes, and then the resulting voltages are measured. An estimation for the cross-sectional resistivity distribution in the object is obtained by using these current and voltage data in a nondestructive manner. In this paper, the electrical impedance imaging of two-phase flows undergoing rapid transient is considered with a special emphasis on the effect of the current pattern on the image reconstruction. The trigonometric current pattern, which is commonly used in the conventional static electrical impedance imaging, shows poor performance in case of the dynamic imaging considered in this work. Extensive numerical experiments are conducted with various kinds of current patterns and their effects on the image reconstruction performance are examined.

  • PDF

A STATIC IMAGE RECONSTRUCTION ALGORITHM IN ELECTRICAL IMPEDANCE TOMOGRAPHY (임피던스 단층촬영기의 정적 영상 복원 알고리즘)

  • Woo, Eung-Je;Webster, John G.;Tompkins, Willis J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.5-7
    • /
    • 1991
  • We have developed an efficient and robust image reconstruction algorithm for static impedance imaging. This improved Newton-Raphson method produced more accurate images by reducing the undesirable effects of the ill-conditioned Hessian matrix. We found that our electrical impedance tomography (EIT) system could produce two-dimensional static images from a physical phantom with 7% spatial resolution at the center and 5% at the periphery. Static EIT image reconstruction requires a large amount of computation. In order to overcome the limitations on reducing the computation time by algorithmic approaches, we implemented the improved Newton-Raphson algorithm on a parallel computer system and showed that the parallel computation could reduce the computation time from hours to minutes.

  • PDF

LONG TERM MONITORING OF HYDRARGYRUM POLLUTED SOIL USING PROJECTED IMAGE RECONSTRUCTION IN ELECTRICAL IMPEDANCE TOMOGRAPHY

  • Munkh-Erdne, Ts;Lee, Eunjung
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.18 no.2
    • /
    • pp.167-180
    • /
    • 2014
  • In this paper we consider a novel reconstruction method in electrical impedance tomography (EIT) and its application for monitoring and detecting a hydrargyrum (mercury) polluted soil near to the surface of underground. We use electrodes placed on the surface of land to collect the data which provides the relations of voltage and current map and to produce a projected image of interior conductivity distribution onto the surface of land. Here the projected image reconstruction method is used to monitor the pollution in soil underneath the ground without any destruction and any digging into a land.

Genetic Algorithm Approach to Image Reconstruction in Electrical Impedance Tomography

  • Kim, Ho-Chan;Boo, Chang-Jin;Lee, Yoon-Joon;Kang, Chang-Ik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.123-128
    • /
    • 2004
  • In electrical impedance tomography (EIT), the internal resistivity distribution of the unknown object is computed using the boundary voltage data induced by different current patterns using various reconstruction algorithms. This paper presents a new image reconstruction algorithm based on the genetic algorithm (GA) via a two-step approach for the solution of the EIT inverse problem, in particular for the reconstruction of "static" images. The computer simulation for the 32 channels synthetic data shows that the spatial resolution of reconstructed images in the proposed scheme is improved compared to that of the modified Newton-Raphson algorithm at the expense of an increased computational burden.rden.

A Image Reconstruction Uing Simulated Annealing in Electrical Impedance Tomograghy (시뮬레이티드 어닐링을 이용한 전기임픽던스단층촬영법의 영상복원)

  • Kim Ho-Chan;Boo Chang-Jin;Lee Yoon-Joon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.2
    • /
    • pp.120-127
    • /
    • 2003
  • In electrical impedance tomography(EIT), various image reconstruction algorithms have been used in order to compute the internal resistivity distribution of the unknown object with its electric potential data at the boundary. Mathematically the EIT image reconstruction algorithm is a nonlinear ill-posed inverse problem. This paper presents a simulated annealing technique as a statistical reconstruction algorithm for the solution of the static EIT inverse problem. Computer simulations with the 32 channels synthetic data show that the spatial resolution of reconstructed images by the proposed scheme is improved as compared to that of the mNR algorithm or genetic algorithm at the expense of increased computational burden.

Electrical Impedance Tomography and Biomedical Applications

  • Woo, Eung-Je
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.1-6
    • /
    • 2007
  • Two impedance imaging systems of multi-frequency electrical impedance tomography (MFEIT) and magnetic resonance electrical impedance tomography (MREIT) are described. MFEIT utilizes boundary measurements of current-voltage data at multiple frequencies to reconstruct cross-sectional images of a complex conductivity distribution (${\sigma}+i{\omega}{\varepsilon}$) inside the human body. The inverse problem in MFEIT is ill-posed due to the nonlinearity and low sensitivity between the boundary measurement and the complex conductivity. In MFEIT, we therefore focus on time- and frequency-difference imaging with a low spatial resolution and high temporal resolution. Multi-frequency time- and frequency-difference images in the frequency range of 10 Hz to 500 kHz are presented. In MREIT, we use an MRI scanner to measure an internal distribution of induced magnetic flux density subject to an injection current. This internal information enables us to reconstruct cross-sectional images of an internal conductivity distribution with a high spatial resolution. Conductivity image of a postmortem canine brain is presented and it shows a clear contrast between gray and white matters. Clinical applications for imaging the brain, breast, thorax, abdomen, and others are briefly discussed.

  • PDF

SPSA Approach to Image Reconstruction in Electrical Impedance Tomograhpy (전기 임피던스 단층촬영법에서 SPSA를 이용한 영상복원)

  • 김호찬;부창진;이윤준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.23-28
    • /
    • 2004
  • In EIT, various image reconstruction algorithms have been used in order to compute the internal resistivity distribution of the unknown object with its electric potential data at the boundary. Mathematically the EIT image reconstruction algorithm is a nonlinear ill-posed inverse problem. In this paper, a SPSA approach is proposed for the solution of the EIT image reconstruction. Results of numerical experiments of EIT solved by the SPSA approach are presented and compared to that obtained by the modified Newton-Raphson(mNR) method.

CoReHA: conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT)

  • Jeon, Ki-Wan;Lee, Chang-Ock;Kim, Hyung-Joong;Woo, Eung-Je;Seo, Jin-Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.279-287
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) is a new medical imaging modality providing cross-sectional images of a conductivity distribution inside an electrically conducting object. MREIT has rapidly progressed in its theory, algorithm and experimental technique and now reached the stage of in vivo animal and human experiments. Conductivity image reconstructions in MREIT require various steps of carefully implemented numerical computations. To facilitate MREIT research, there is a pressing need for an MREIT software package with an efficient user interface. In this paper, we present an example of such a software, called CoReHA which stands for conductivity reconstructor using harmonic algorithms. It offers various computational tools including preprocessing of MREIT data, identification of boundary geometry, electrode modeling, meshing and implementation of the finite element method. Conductivity image reconstruction methods based on the harmonic $B_z$ algorithm are used to produce cross-sectional conductivity images. After summarizing basics of MREIT theory and experimental method, we describe technical details of each data processing task for conductivity image reconstructions. We pay attention to pitfalls and cautions in their numerical implementations. The presented software will be useful to researchers in the field of MREIT for simulation as well as experimental studies.