• 제목/요약/키워드: Image Detector

검색결과 914건 처리시간 0.022초

SPATIAL AND ENERGY RESOLUTIONS OF A HEXAGONAL ANIMAL PET SCANNER BASED ON LGSO CRYSTAL AND FLAT-PANEL PMT

  • Lee, Chan-Mi;Hong, Seong-Jong;Yoon, Hyun-Suk;Ito, Mikiko;Kwon, Sun-Il;Park, Sang-Keun;Lee, Dong-Soo;Sim, Kwang-Souk;Lee, Jae-Sung
    • Nuclear Engineering and Technology
    • /
    • 제44권1호
    • /
    • pp.53-60
    • /
    • 2012
  • The aim of this study was to explore the spatial and energy resolutions of a PET scanner that we have recently developed. The scanner, which consists of six detector modules with 1-layer LGSO crystals, has a hexagonal configuration with a faceto- face distance of 86.4 mm between two opposite PET modules; such properties facilitate the imaging of small animals. A $^{22}Na$ point source was employed to estimate horizontal and vertical spatial resolutions. To assess the energy resolution, a uniform $^{18}F$ cylindrical phantom was scanned. A software-based spectrum analysis of list-mode data was used to assign a local energy window centered on the photopeak position for every single crystal. For the image reconstruction, an ML-EM algorithm was used. The spatial resolutions at the center of the scanner were 0.99 mm in the horizontal direction and 1.13 mm in the vertical direction. The energy resolution averaged over each PMT ranged from 13.3%-14.3%, which gave an average value of 13.8%. These results show that this simple system is promising for small animal imaging with excellent spatial and energy resolutions.

UV Responsive Characteristics of n-Channel Schottky Barrier MOSFET with ITO as Source/Drain Contacts

  • Kim, Tae-Hyeon;Lee, Chang-Ju;Kim, Dong-Seok;Sung, Sang-Yun;Heo, Young-Woo;Lee, Jung-Hee;Hahm, Sung-Ho
    • 센서학회지
    • /
    • 제20권3호
    • /
    • pp.156-161
    • /
    • 2011
  • We fabricated a schottky barrier metal oxide semiconductor field effect transistor(SB-MOSFET) by applying indium-tin-oxide(ITO) to the source/drain on a highly resistive GaN layer grown on a silicon substrate. The MOSFET, with 10 ${\mu}M$ gate length and 100 ${\mu}M$ gate width, exhibits a threshold gate voltage of 2.7 V, and has a sub-threshold slope of 240 mV/dec taken from the $I_{DS}-V_{GS}$ characteristics at a low drain voltage of 0.05 V. The maximum drain current is 18 mA/mm and the maximum transconductance is 6 mS/mm at $V_{DS}$=3 V. We observed that the spectral photo-response characterization exhibits that the cutoff wavelength was 365 nm, and the UV/visible rejection ratio was about 130 at $V_{DS}$ = 5 V. The MOSFET-type UV detector using ITO, has a high UV photo-responsivity and so is highly applicable to the UV image sensors.

고성능 실시간 얼굴 검출 엔진의 설계 및 구현 (Design and Implementation of Real-time High Performance Face Detection Engine)

  • 한동일;조현종;최종호;조재일
    • 대한전자공학회논문지SP
    • /
    • 제47권2호
    • /
    • pp.33-44
    • /
    • 2010
  • 본 논문에서는 로봇 시각 처리 활용을 위한 실시간 얼굴 검출 하드웨어 구조를 제안한다. 제안한 구조는 조명 변화에 강인하고 초당 60 프레임 이상의 속도로 처리된다. 조명 변화에 강인한 얼굴 특성 추출을 위해 MCT(Modified Census Transform) 변환을 이용하였다. 그리고 AdaBoost 알고리즘은 얼굴 특징 데이터의 학습 및 생성을 하며, 이 생성된 학습 데이터를 이용해 얼굴 검출을 하게 된다. 본 논문에서는 메모리 인터페이스부, 이미지 크기 조정부, MCT 생성부, 후보 얼굴 검출부, 신뢰도 비교부, 좌표 재조정부, 데이터 그룹화부, 검출 결과 표시부로 구성된 얼굴 검출 하드웨어 구조 및 Xilinx사의 Virtex5 LX330 FPGA를 이용한 하드웨어 구현 검증 결과에 대해 설명한다. 카메라로 부터 입력받은 이미지를 이용해 검증한 결과로 초당 최대 149프레임의 속도로 한 프레엠 당 최대 32개 얼굴을 검출함을 확인하였다.

치과구내용 X선발생기의 조사통 직경 변화에 따른 선량변화 (Dose Change according to Diameter Change of the Cone for Dental X-ray Apparatus)

  • 안성민;오정환;최정현;신귀순;김성철
    • 한국콘텐츠학회논문지
    • /
    • 제10권3호
    • /
    • pp.266-270
    • /
    • 2010
  • 진단용방사선발생장치의 안전관리법에 의하면 치과 구내촬영용 X선발생기의 경우 조사통의 조사야 크기는 촬영면에서의 최대지름이 7 cm이하가 되게 기준 되어있다. 하지만 실제 두개부에 붙여서 촬영하는 근접촬영이기 때문에 X선 조사면적을 벗어날 염려가 없으며, 구내촬영에 사용되는 필름 또는 디지털 디텍터의 크기도 $3\times4cm^2$의 크기이기 때문에 훨씬 큰 편이며, 근거리 촬영에 따른 환자의 피부선량도 무시할 수 가 없다. 이에 조사통의 지름을 0.5 cm간격으로 줄이며, 환자선량, 해상력 및 화질의 영향을 알아본 결과 조사통 직경이 5 cm가 되어도 사용에 따른 큰 불편이 없으면서 환자선량 감소 및 사진의 대조도 증가 효과를 볼 수 있어 정책적으로 검토해볼 사항이라는 연구 결과를 얻었다

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • 제34권4호
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

SPOT-5 위성영상에 의한 2005년 한국 연안 김 양식장의 시설현황 분석 (Facilities Analysis of Laver Cultivation Grounds in Korean Coastal Waters Using SPOT-5 Images in 2005)

  • 양찬수;박성우
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제9권3호
    • /
    • pp.168-175
    • /
    • 2006
  • 연안 김 양식장의 효과적 관리를 위해서는 실제 시설량의 조사가 필요하며, 인공위성을 이용한 방법이 가장 효과적이다. 본 연구에서는 10m의 해상도를 갖고 있는 SPOT-5 다중분광영상을 사용하였으며, 경기도 화성시 제부도 남방 해역에 김 양식장의 자동탐지 기법을 적용하고 평가하였다. 김 양식장을 추출하기 위하여 우선 3밴드 영상의 분광 특성을 이용한 밴드차(Band difference) 영상을 작성하여, 두 가지 방법(형태학적 처리기법 및 Canny 에지 탐지기법)으로 처리를 한 후, 두 결과를 합성하여 레이블링함으로써 탐지율을 극대화하였다. 인공위성영상을 이용하여 얻어진 2005년 한국연안 김 양식장 시설량은 676,749책(柵)으로, 면허시설량 572,745책보다 많은 것으로 나타났다. 또한, 준법시설 비율은 52.9%로 아주 낮았다. 이와 같은 양식장 시설 현황 조사 결과는, 정부에서 전체 생산량을 조절할 수 있게 하여 안정적인 시장 가격을 유지하는데 도움이 될 수 있을 것이다.

  • PDF

단순화 된 열 저항 해석을 이용한 우주용 FPA 열제어 설계 방안 연구 (Study on Methodology of Trade-Off for Space-borne FPA Thermal Design by Simplified Thermal Node Analysis)

  • 장진수;양승욱;김종운;김이을
    • 한국항공우주학회지
    • /
    • 제43권2호
    • /
    • pp.179-185
    • /
    • 2015
  • 우주용 고해상도 전자광학카메라의 개발에 있어 초점면 배열 장치(Focal Plane Assembly, FPA)의 열제어 설계는 영상품질을 결정하는 중요한 요소이다. FPA 열제어 설계의 목표는 영상 촬영 기간 중 안정적인 열 환경을 제공하는 것으로, 촬영 기간 동안 운용 온도를 주어진 범위 내로 유지해야 하며 후속 촬영에 문제가 없도록 빠른 시간 내에 온도 초기화를 완료해야 한다. 상기의 두 항목인 온도 유지와 온도 초기화 중에서 FPA 구조 설계에 따른 영향을 가장 많이 받으며, 설계 변경의 자유도가 상대적으로 낮은 온도 유지 항목에 대하여 FPA 구조설계 초기 단계부터 검토 및 반영이 가능한 단순화 된 열 저항 해석 기반의 온도 예측 방안을 정의하였다. 또한 열해석 결과와의 비교를 통해 온도 예측 방안을 검증, FPA 설계를 위한 trade-off에 효과적으로 사용할 수 있음을 확인하였다.

Development of a Data Reduction Algorithm for Optical Wide Field Patrol (OWL) II: Improving Measurement of Lengths of Detected Streaks

  • Park, Sun-Youp;Choi, Jin;Roh, Dong-Goo;Park, Maru;Jo, Jung Hyun;Yim, Hong-Suh;Park, Young-Sik;Bae, Young-Ho;Park, Jang-Hyun;Moon, Hong-Kyu;Choi, Young-Jun;Cho, Sungki;Choi, Eun-Jung
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권3호
    • /
    • pp.221-227
    • /
    • 2016
  • As described in the previous paper (Park et al. 2013), the detector subsystem of optical wide-field patrol (OWL) provides many observational data points of a single artificial satellite or space debris in the form of small streaks, using a chopper system and a time tagger. The position and the corresponding time data are matched assuming that the length of a streak on the CCD frame is proportional to the time duration of the exposure during which the chopper blades do not obscure the CCD window. In the previous study, however, the length was measured using the diagonal of the rectangle of the image area containing the streak; the results were quite ambiguous and inaccurate, allowing possible matching error of positions and time data. Furthermore, because only one (position, time) data point is created from one streak, the efficiency of the observation decreases. To define the length of a streak correctly, it is important to locate the endpoints of a streak. In this paper, a method using a differential convolution mask pattern is tested. This method can be used to obtain the positions where the pixel values are changed sharply. These endpoints can be regarded as directly detected positional data, and the number of data points is doubled by this result.

부분용적효과 제거를 위한 Filter 구현 (Implementation of Filter for the Removal of Partial Volume Effect)

  • 박민주;이상복
    • 한국방사선학회논문지
    • /
    • 제9권3호
    • /
    • pp.139-145
    • /
    • 2015
  • SPECT를 이용한 환자의 검사 시 몸 안에서 방출되는 ${\gamma}$-선은 감쇠 또는 산란 등의 현상이 일어나며, 검출기에 도달할 때 조준기의 물리적 특성과 기학적인 모양에 따라 퍼지는 현상이 발생하여 정량분석이 불가능하였다. 체내에서 방출되는 ${\gamma}$-선의 정확한 정량분석을 위해서는 반드시 부분용적효과에 대한 보정이 고려되어야 한다. 본 논문에서는 SPECT의 종합적인 부분용적효과를 해결하기 위하여 Sinogram Filter를 구현하였다. 구현된 Filter를 적용하여 실험을 한 결과, SPECT에서 발생되는 부분용적효과를 제거하였다. 기존방법과 제안한 방법을 비교하기 위하여 PSNR을 시행한 결과 제안한 방법으로 한 경우 PSNR은 7 dB, 기존방법은 14 dB로 나왔다. 제안한 방법의 dB이 낮아진 이유는 산란선 제거를 많이 하여 MSE가 높아지기 때문에 PSNR값이 낮게 나타났다. 따라서 제안한 방법을 적용한다면 SPECT 영상의 부분용적효과를 제거하여 영상의 질이 좋아질 것이다.

인체 감지용 강유전체 박막 초전형 적외선 센서의 제작 (Pyroelectric Infrared Microsensors Made for Human Body Detection)

  • 최준림
    • 센서학회지
    • /
    • 제7권2호
    • /
    • pp.103-110
    • /
    • 1998
  • 강유전체 박막과 마이크로 가공기술을 이용하여 초전형 적외선 센서를 제작하였다. 초전형 적외선 센서는 $Pb_{l-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.05) (PLT) 강유전체 박막 커패시터를 RF 마그네트론 스퍼터링 방식으로 백감 전극이 증착된 MgO 기판상에 결정 성장시킨 구조를 갖고 있다. 스퍼터링된 PLT 박막은 높은 c-축 결정 구조를 가지므로 센서로 사용하기 위한 분극 처리 과정이 필요 없다. 이는 적외선 이미지 센서를 구현함에 있어서 수율 향상에 필수적인 요소이다. 또한 마이크로 가공 기술을 사용하여 센서의 열용량을 극소화함으로서 센서의 효율을 최대화하였다. 제작된 센서의 상부에 폴리이미드를 코팅하고 MgO 기판을 선택적으로 식각하여 코팅된 폴리이미드와 MgO가 강유전체 박막 커패시터를 지지하고 있는 구조를 구현하였다. 이렇게 제작된 센서의 감도는 상온에서 $8.5{\times}10^{8}cm{\cdot}\sqrt{Hz}/W$로 측정되었으며 이는 마이크로 가공 기술을 사용하지 않은 경우보다 약 100 배의 감도 향상을 가져왔다. 2차원 배열 구조를 갖는 센서를 가지고 인체의 유 무 뿐만 아니라 위치까지 감별할 수 있는 센싱 시스템을 구현하였다.

  • PDF