• Title/Summary/Keyword: Image Detector

Search Result 914, Processing Time 0.022 seconds

SPATIAL AND ENERGY RESOLUTIONS OF A HEXAGONAL ANIMAL PET SCANNER BASED ON LGSO CRYSTAL AND FLAT-PANEL PMT

  • Lee, Chan-Mi;Hong, Seong-Jong;Yoon, Hyun-Suk;Ito, Mikiko;Kwon, Sun-Il;Park, Sang-Keun;Lee, Dong-Soo;Sim, Kwang-Souk;Lee, Jae-Sung
    • Nuclear Engineering and Technology
    • /
    • v.44 no.1
    • /
    • pp.53-60
    • /
    • 2012
  • The aim of this study was to explore the spatial and energy resolutions of a PET scanner that we have recently developed. The scanner, which consists of six detector modules with 1-layer LGSO crystals, has a hexagonal configuration with a faceto- face distance of 86.4 mm between two opposite PET modules; such properties facilitate the imaging of small animals. A $^{22}Na$ point source was employed to estimate horizontal and vertical spatial resolutions. To assess the energy resolution, a uniform $^{18}F$ cylindrical phantom was scanned. A software-based spectrum analysis of list-mode data was used to assign a local energy window centered on the photopeak position for every single crystal. For the image reconstruction, an ML-EM algorithm was used. The spatial resolutions at the center of the scanner were 0.99 mm in the horizontal direction and 1.13 mm in the vertical direction. The energy resolution averaged over each PMT ranged from 13.3%-14.3%, which gave an average value of 13.8%. These results show that this simple system is promising for small animal imaging with excellent spatial and energy resolutions.

UV Responsive Characteristics of n-Channel Schottky Barrier MOSFET with ITO as Source/Drain Contacts

  • Kim, Tae-Hyeon;Lee, Chang-Ju;Kim, Dong-Seok;Sung, Sang-Yun;Heo, Young-Woo;Lee, Jung-Hee;Hahm, Sung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • We fabricated a schottky barrier metal oxide semiconductor field effect transistor(SB-MOSFET) by applying indium-tin-oxide(ITO) to the source/drain on a highly resistive GaN layer grown on a silicon substrate. The MOSFET, with 10 ${\mu}M$ gate length and 100 ${\mu}M$ gate width, exhibits a threshold gate voltage of 2.7 V, and has a sub-threshold slope of 240 mV/dec taken from the $I_{DS}-V_{GS}$ characteristics at a low drain voltage of 0.05 V. The maximum drain current is 18 mA/mm and the maximum transconductance is 6 mS/mm at $V_{DS}$=3 V. We observed that the spectral photo-response characterization exhibits that the cutoff wavelength was 365 nm, and the UV/visible rejection ratio was about 130 at $V_{DS}$ = 5 V. The MOSFET-type UV detector using ITO, has a high UV photo-responsivity and so is highly applicable to the UV image sensors.

Design and Implementation of Real-time High Performance Face Detection Engine (고성능 실시간 얼굴 검출 엔진의 설계 및 구현)

  • Han, Dong-Il;Cho, Hyun-Jong;Choi, Jong-Ho;Cho, Jae-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.2
    • /
    • pp.33-44
    • /
    • 2010
  • This paper propose the structure of real-time face detection hardware architecture for robot vision processing applications. The proposed architecture is robust against illumination changes and operates at no less than 60 frames per second. It uses Modified Census Transform to obtain face characteristics robust against illumination changes. And the AdaBoost algorithm is adopted to learn and generate the characteristics of the face data, and finally detected the face using this data. This paper describes the face detection hardware structure composed of Memory Interface, Image Scaler, MCT Generator, Candidate Detector, Confidence Comparator, Position Resizer, Data Grouper, and Detected Result Display, and verification Result of Hardware Implementation with using Virtex5 LX330 FPGA of Xilinx. Verification result with using the images from a camera showed that maximum 32 faces per one frame can be detected at the speed of maximum 149 frame per second.

Dose Change according to Diameter Change of the Cone for Dental X-ray Apparatus (치과구내용 X선발생기의 조사통 직경 변화에 따른 선량변화)

  • Ahn, Sung-Min;Oh, Jung-Hoan;Choi, Jung-Hyun;Shin, Gwi-Soon;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.266-270
    • /
    • 2010
  • In case of the Dental X-ray apparatus, the diameter (or the field size) of the tip of the cone should be less than 7 cm according to the Diagnosis Radiation Equipment Safety Management. However, deviation from the field is not expected to be big as photography is made at close range from the skin. Also, as the size of film or digital detector used in intra-oral photography is $3\times4cm^2$, the size mentioned above can be considered to be much bigger. Furthermore, the patient dose by short-distance photography can not be ignored. Therefore, effect on the patient dose, resolution and image qualty was examined by reducing the cone diameter by 0.5 cm interval. The result showed that the patient dose was reduced and a partial improvement in picture contrast was observed. Therefore, it can be concluded from these results that further investigation may be worthwhile in terms of policy.

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

Facilities Analysis of Laver Cultivation Grounds in Korean Coastal Waters Using SPOT-5 Images in 2005 (SPOT-5 위성영상에 의한 2005년 한국 연안 김 양식장의 시설현황 분석)

  • Yang Chan-Su;Park Sung-Woo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.3
    • /
    • pp.168-175
    • /
    • 2006
  • The cultural grounds of lave r have been surveyed using SPOT-5 satellite images. The facilities of laver cultivation area in the coastal waters of Korea were calculated. 10 m resolution multispectral images of SPOT-5 are adopted for the southern are a of Jebu Island, Hwaseong city to develop an automatic detection approach of laver nets that consists of the following: band difference technique, canny edge detector and morphological analysis: The number of satellite-based facilities was relatively high as compared with the licensed number in 2005, 676,749 chaek and 572,745 chaek(柵, unit of measure for laver farm), respectively. The ratio of a law abiding facility was very low at 52.9%. These data could be applied to control its national production keeping a stable market price for the government body.

  • PDF

Study on Methodology of Trade-Off for Space-borne FPA Thermal Design by Simplified Thermal Node Analysis (단순화 된 열 저항 해석을 이용한 우주용 FPA 열제어 설계 방안 연구)

  • Chang, Jin-Soo;Yang, Seung-Uk;Kim, Jong-Un;Kim, Ee-Eul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.179-185
    • /
    • 2015
  • The main objective of thermal design for a space-borne FPA(Focal Plane Assembly) is to provide stable thermal environment during imaging operation and thus maintain the image quality. An FPA must be maintained within its operating temperature range and cooled down to its initial temperature soon enough for the next imaging operation. This paper describes the study result on performing trade-off studies for FPA thermal design by using simplified thermal node analysis about FPA preliminary design. It also describes the verification results of the study by comparing thermal analysis results and trade-off study results. According to results, we can conclude that this approach is useful for simple and quick trade-off studies without thermal analysis based on thermal math models.

Development of a Data Reduction Algorithm for Optical Wide Field Patrol (OWL) II: Improving Measurement of Lengths of Detected Streaks

  • Park, Sun-Youp;Choi, Jin;Roh, Dong-Goo;Park, Maru;Jo, Jung Hyun;Yim, Hong-Suh;Park, Young-Sik;Bae, Young-Ho;Park, Jang-Hyun;Moon, Hong-Kyu;Choi, Young-Jun;Cho, Sungki;Choi, Eun-Jung
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.221-227
    • /
    • 2016
  • As described in the previous paper (Park et al. 2013), the detector subsystem of optical wide-field patrol (OWL) provides many observational data points of a single artificial satellite or space debris in the form of small streaks, using a chopper system and a time tagger. The position and the corresponding time data are matched assuming that the length of a streak on the CCD frame is proportional to the time duration of the exposure during which the chopper blades do not obscure the CCD window. In the previous study, however, the length was measured using the diagonal of the rectangle of the image area containing the streak; the results were quite ambiguous and inaccurate, allowing possible matching error of positions and time data. Furthermore, because only one (position, time) data point is created from one streak, the efficiency of the observation decreases. To define the length of a streak correctly, it is important to locate the endpoints of a streak. In this paper, a method using a differential convolution mask pattern is tested. This method can be used to obtain the positions where the pixel values are changed sharply. These endpoints can be regarded as directly detected positional data, and the number of data points is doubled by this result.

Implementation of Filter for the Removal of Partial Volume Effect (부분용적효과 제거를 위한 Filter 구현)

  • Park, Minju;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • When examining a patient using SPECT, gamma rays emitted from the body decrease or scatter. And when they reach the detector they spread in accordance with physical characteristics and geometric shapes of the scanner, quantitative analysis was difficult. For exact quantitative analysis of gamma rays emitted from the body, so that they must be considered to correction about PVE(partial volume effect). In this paper, sinogram filter was implemented to solve comprehensive PVE of SPECT. According to the results in which implemented filter was applied, partial volume effect caused by SPECT was removed. To compare proposed method and conventional method, PSNR(Peak Signal to Noise Ratio) was executed. As a result, proposed method was indicated as 7dB, conventional method was indicated as 14db respectively. dB(decibel) level of the proposed methods is lower, since the MSE(mean square error) becomes greater because scattered ray was removed, PSNR value is low. Therefore, by applying the proposed method for removing the PVE of SPECT imaging method, the image quality is improved.

Pyroelectric Infrared Microsensors Made for Human Body Detection (인체 감지용 강유전체 박막 초전형 적외선 센서의 제작)

  • Choi, Jun-Rim
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.103-110
    • /
    • 1998
  • Pyroelectric infrared detectors based on La-modified $PbTiO_{3}$ (PLT) thin films have been fabricated by RF magnetron sputtering and rnicrornachining technology. The detectors form $Pb_{l-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.05) thin film ferroelectric capacitors epitaxially grown by RF magnetron sputtering on Pt/MgO (100) substrate. The sputtered PLT thin film exhibits highly c-axis oriented crystal structure that no poling treatment for sensing applications is required. This is an essential factor to increase the yield for realization of an infrared image sensor. Micromachining technology is used to lower the thermal mass of the detector by giving maximum sensor efficiency. Polymide is coated on top of the sensing elements to support the fragile structure and the backside of the MgO substrate is selectively etched to reduce the heat loss. The sensing element exhibited a very high detectivity D* of $8.5{\times}10^{8}cm{\cdot}\sqrt{Hz}/W$ at room temperature and it is about 100 times higher than the case of micromachining technology is not used. A sensing system that detects the position as well as the existence of a human body is realized using the array sensor.

  • PDF