• Title/Summary/Keyword: Image Degradation

Search Result 639, Processing Time 0.023 seconds

Manipulation of the Compressed Video for Multimedia Networking : A Bit rate Shaping of the Compressed Video (멀티미디어 네트워킹을 위한 압축 신호상에서 동영상 처리 : 압축 동영상 비트율 변환)

  • 황대환;조규섭;황수용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11A
    • /
    • pp.1908-1924
    • /
    • 2001
  • Interoperability and inter-working in the various network and media environment with different technology background is very important to enlarge the opportunity of service access and to increase the competitive power of service. The ITU-T and advanced counties are planning ahead for provision of GII enabling user to access advanced global communication services supporting multimedia communication applications, embracing all modes of information. In this paper, we especially forced the heterogeneity of end user applications for multimedia networking. The heterogeneity has several technical aspects, like different medium access methods, heterogeneous coding algorithms for audio-visual data and so on. Among these elements, we have been itemized bit rate shaping algorithm on the compressed moving video. Previous manipulations of video has been done on the uncompressed signal domain. That is, compressed video should be converted to linear PCM signal. To do such a procedures, we should decode, manipulate and then encode the video to compressed signal once again. The traditional approach for processing the video signa1 has several critical weak points, requiring complexity to implement, degradation of image quality and large processing delay. The bit rate shaping algorithm proposed in this paper process the manipulation of moving video on the completely compressed domain to cope with above deficit. With this algorithms. we could realized efficient video bit rate shaping and the result of software simulation shows that this method has significant advantage than that of pixel oriented algorithms.

  • PDF

Changes in Spatial Resolution at Position of the Detector in Digital Mammography System (디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화)

  • Kim, Hye-Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.215-222
    • /
    • 2016
  • X-ray mammography is the most effective method for the diagnosis of calcified lesions of various breast diseases. To reduce patient dose and to obtain optimal image required for diagnosis, the performance of the mammography system should be maintained continuously. Because the target (anode) angle of the X-ray tube is measured from the central X-ray, the effective angle can be slightly different in view of the position on the detector, which can result in degrading spatial resolution of the imaging within the field of view. In this study, we measured the MTF to examine spatial resolution for positions on the detector in the digital mammography system. For a tungsten wire of $50{\mu}m$ diameter, the highest spatial frequency was obtained. It meant that a wire diameter for measuring MTF through LSF should be small compared to the pixel size of the detector used in the mammography system. The spatial resolution showed slightly different performance according to positions on the detector. The center position gave the best spatial resolution and positions away from the center showed the degraded performance although the difference of the spatial resolution was small. The effective focal spot size of the full width at half maximum also showed similar result. It concluded that the slightly increase of the effective focal spot size gave the degradation of the spatial resolution for positions on the detector.

Evaluation of Growth Inhibition for Microcystis aeruginosa with Different Frequency of Ultrasonic Devices (초음파 장치의 주파수 변화에 따른 Microcystis aeruginosa의 성장억제 평가)

  • Jang, So Ye;Joo, Jin Chul;Kang, Eun Byeol;Ahn, Chae Min;Park, Jeongsu;Jeong, Moo Il;Lee, Dong Ho
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.3
    • /
    • pp.143-153
    • /
    • 2021
  • The growth inhibition effects of M. aeruginosa were verified using large volume (7.2 L) of algae samples and ultrasonication (high frequency of 1.6 MHz vs. low frequency of 23 kHz) in lab-scale experiment. The chlorophyll-a (chl-a) and cell number decreased gradually after 6 hr sonication with high frequency of 1.6 MHz whereas both decreased sharply after 6 hr sonication with low frequency of 23 kHz. Additionally, the first order degradation coefficient (k) values after sonication were greater than those during sonication. These results indicate that relatively low sonication energy per volume may affect the cell membrane and internal organs of M. aeruginosa in a slow and retarded manner and resulted in gradual decrease of cell numbers of M. aeruginosa. Based on the comparison of chl-a and cell number of M. aeruginosa after sonication, low frequency of 23 kHz is superior for growth inhibition of M. aeruginosa, since low frequency of 23 kHz easily penetrates the cell membrane and ruptures the internal organs including gas vesicles. As is evident in SEM and TEM images, ruptured cell membranes were clearly observed for low frequency of 23 kHz. Finally, the microcystin-LR in water is not detected and considered to be harmless in aquaculture systems.

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.

A Study on Problems and Improvement Plans of Non-Face-to-Face Midi Classes (비대면 미디 수업의 문제점과 개선 방안 연구)

  • Baek, Sung-Hyun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.4
    • /
    • pp.267-277
    • /
    • 2021
  • Both teachers and learners should participate in non-face-to-face class due to COVID-19. The non-face-to-face class has brought about many problems, where they made adequate preparations for such abrupt situation. This study attempted to understand and improve problems occurring during non-face-to-face midi class. The findings are as follows: First, there were differences in equipment available to contact and non-face-to-face class. Such a problem could be improved by using Reaper, DAW which can be installed and freely utilized without any functional limits, regardless of the types of operating systems. Second, latency could not be reduced, when the screen share function of Zoom was used, since it was impossible to select audio interface's drivers in DAW. This problem was improved by again receiving audio output as input and sending it, from the perspectives of teachers. In addition, learners who used the operating system of Windows and have no audio interfaces usually suffer from latency during practices. The latency can be reduced by installing Asio4all. Third, image degradation and screen disconnection phenomena occurred due to the lack of resource. Two computers were connected by using a capture board and the screen disconnection phenomena could be improved by distributing resources and maintaining high-resolution. The system for allowing non-face-to-face midi class could be successfully established, as one more computer was connected by using Vienna Ensemble Pro and more plug-ins were used by securing additional resources. Consequently, the problems of non-face-to-face midi class could be understood and improved.

Comparison of Semantic Segmentation Performance of U-Net according to the Ratio of Small Objects for Nuclear Activity Monitoring (핵활동 모니터링을 위한 소형객체 비율에 따른 U-Net의 의미론적 분할 성능 비교)

  • Lee, Jinmin;Kim, Taeheon;Lee, Changhui;Lee, Hyunjin;Song, Ahram;Han, Youkyung
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_4
    • /
    • pp.1925-1934
    • /
    • 2022
  • Monitoring nuclear activity for inaccessible areas using remote sensing technology is essential for nuclear non-proliferation. In recent years, deep learning has been actively used to detect nuclear-activity-related small objects. However, high-resolution satellite imagery containing small objects can result in class imbalance. As a result, there is a performance degradation problem in detecting small objects. Therefore, this study aims to improve detection accuracy by analyzing the effect of the ratio of small objects related to nuclear activity in the input data for the performance of the deep learning model. To this end, six case datasets with different ratios of small object pixels were generated and a U-Net model was trained for each case. Following that, each trained model was evaluated quantitatively and qualitatively using a test dataset containing various types of small object classes. The results of this study confirm that when the ratio of object pixels in the input image is adjusted, small objects related to nuclear activity can be detected efficiently. This study suggests that the performance of deep learning can be improved by adjusting the object pixel ratio of input data in the training dataset.

Optimization-based Deep Learning Model to Localize L3 Slice in Whole Body Computerized Tomography Images (컴퓨터 단층촬영 영상에서 3번 요추부 슬라이스 검출을 위한 최적화 기반 딥러닝 모델)

  • Seongwon Chae;Jae-Hyun Jo;Ye-Eun Park;Jin-Hyoung, Jeong;Sung Jin Kim;Ahnryul Choi
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.331-337
    • /
    • 2023
  • In this paper, we propose a deep learning model to detect lumbar 3 (L3) CT images to determine the occurrence and degree of sarcopenia. In addition, we would like to propose an optimization technique that uses oversampling ratio and class weight as design parameters to address the problem of performance degradation due to data imbalance between L3 level and non-L3 level portions of CT data. In order to train and test the model, a total of 150 whole-body CT images of 104 prostate cancer patients and 46 bladder cancer patients who visited Gangneung Asan Medical Center were used. The deep learning model used ResNet50, and the design parameters of the optimization technique were selected as six types of model hyperparameters, data augmentation ratio, and class weight. It was confirmed that the proposed optimization-based L3 level extraction model reduced the median L3 error by about 1.0 slices compared to the control model (a model that optimized only 5 types of hyperparameters). Through the results of this study, accurate L3 slice detection was possible, and additionally, we were able to present the possibility of effectively solving the data imbalance problem through oversampling through data augmentation and class weight adjustment.

Development of a Deep-Learning Model with Maritime Environment Simulation for Detection of Distress Ships from Drone Images (드론 영상 기반 조난 선박 탐지를 위한 해양 환경 시뮬레이션을 활용한 딥러닝 모델 개발)

  • Jeonghyo Oh;Juhee Lee;Euiik Jeon;Impyeong Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1451-1466
    • /
    • 2023
  • In the context of maritime emergencies, the utilization of drones has rapidly increased, with a particular focus on their application in search and rescue operations. Deep learning models utilizing drone images for the rapid detection of distressed vessels and other maritime drift objects are gaining attention. However, effective training of such models necessitates a substantial amount of diverse training data that considers various weather conditions and vessel states. The lack of such data can lead to a degradation in the performance of trained models. This study aims to enhance the performance of deep learning models for distress ship detection by developing a maritime environment simulator to augment the dataset. The simulator allows for the configuration of various weather conditions, vessel states such as sinking or capsizing, and specifications and characteristics of drones and sensors. Training the deep learning model with the dataset generated through simulation resulted in improved detection performance, including accuracy and recall, when compared to models trained solely on actual drone image datasets. In particular, the accuracy of distress ship detection in adverse weather conditions, such as rain or fog, increased by approximately 2-5%, with a significant reduction in the rate of undetected instances. These results demonstrate the practical and effective contribution of the developed simulator in simulating diverse scenarios for model training. Furthermore, the distress ship detection deep learning model based on this approach is expected to be efficiently applied in maritime search and rescue operations.

Development of Adaptive Spatial Filter to Improve Noise Characteristics of PET Images (PET 영상의 잡음개선을 위한 적응적 공간 필터 개발)

  • Woo, S. K.;Choi, Y.;Im, K. C.;Song, T. Y.;Jung, J. H.;Lee, K. H.;Kim, S. E.;Choe, Y. S.;Park, C. C.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.253-261
    • /
    • 2002
  • A spatially adaptive falter was formulated to imrove PET image qualify and the Performance of the filter was evaluated using simulation and phantom and human PET studies. In the proposed filter. if a pixel was identified as the edge Pixel, the Pixel value was Preserved. Otherwise a Pixel was replaced by the mean of the pixel values weighted by 2:7: 2. A Pixel was identified as the edge Pixel. if it satisfies the following conditions : the number of ADs (absolute difference between center and neighborhood pixels) which is smaller than THl (($pix_max{\times}0.1/log_2(NPM)$, NPM : mean of 6 neighborhood pixels excluding minimum and maximum) is 8-k and the number of ADs which is lager than TH2 ($NPM{\times}0.1$) is k. where k : 2, 3, …, 6. The results of this study demonstrate the superior performance of the Proposed titter compared to Gaussian fitter, weight median filter and subset averaged median filter. The proposed tittering method is simple but effective in increasing uniformity and contrast with minimal degradation of spatial resolution of PET images and thus. is expected to Provide improved diagnositc quality PET images .

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF