• Title/Summary/Keyword: IT Equipment/Server

Search Result 135, Processing Time 0.026 seconds

Design of HMI software Interoperable with OPC-DA Server (OPC Server와 연동되는 HMI 소프트웨어 설계)

  • Cha, Jae-Pil;Jang, Dong-Wook;Jo, Sang-Hyun;Sun, Bok-Keun;Kim, Su-Hee;Han, Kwang-Rok
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.801-802
    • /
    • 2006
  • The present study purposes to develop HMI software that runs on Windows CE .NET platform without being bound to specific HMI equipment and accesses data in PLC equipment through interoperation with an OPC-DA server. As the OPC-DA server reads data in PLC equipment, HMI system does not need to be configured differently for different equipments. In addition, when the interface environment of specific equipment changes, it does not require the application of new equipment or the change of communication protocol. As HMI system runs on Windows CE .NET platform, it can be configured using common embedded devices based on Windows CE .NET platform. HMI software reads data in PLC equipment through RS-232C communication interface. In addition, because it connects to an OPC-DA server through Ethernet communication interface, it can access data in PLC equipment as long as Ethernet is usable.

  • PDF

An Embedded Web Server for Remote Monitoring the Semiconductor Equipment (반도체 장비의 원격 모니터링을 위한 임베디드 웹 서버)

  • 윤한경;임성락
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.3
    • /
    • pp.13-18
    • /
    • 2003
  • A remote monitoring system of the semiconductor equipment is used to monitor or control operations of the equipment. Most of the conventional monitoring systems are based on the client-server model with the general purpose PC. Basically, it implies the difficulties in the system reliability and cost down due to its size and complexity. To overcome these difficulties, we suggest an embedded web server which is based on the low-cost microprocessor. It is designed for the monitoring or controlling a dedicated equipment only. To evaluate the feasibility of the suggested embedded web server, we have implemented a test-board with ATMega103 and programmed the basic modules using the AVR-GCC. Finally, we have tested its operations on the MS Explorer 6.0 environment.

  • PDF

Power and Heat Load of IT Equipment Projections for New Data Center's HVAC System Design (데이터센터의 공조시스템 계획을 위한 IT장비의 전력 및 발열량 예측에 대한 연구)

  • Cho, Jin-Kyun;Shin, Seung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.212-217
    • /
    • 2012
  • The cooling of data centers has emerged as a significant challenge as the density of IT equipment increased. With the rapid increasing of heat load and cooling system, predictions for electronics power trends have been closely watched. A data center power density projection is needed so that IT organizations can develop data centers with adequate cooling for reasonable lifetimes. This paper will discuss the need for something more than processor and equipment power trend projections which have overestimated the required infrastructure for customers. This projection will use data from a survey of actual enterprise data centers and the ASHRAE projections to formulate a data center server heat load trend projection.

The Design for Packet Transmission Technology of Vehicle and Base Station in the Intelligent Transport System (지능형 교통시스템에서 차량과 기지국의 패킷전송기술 설계)

  • Lee, Dae Sik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 2013
  • In this paper which it is relating to the DSRC system based road side equipment, we propose the protocol stack architecture of road side equipment and the process structure of the main RM, L7 and LLC layers which is road side equipment device as well. And also we design the signal flow and data-transfer process as well between road side equipment and on board equipment to describe the installation process between road side equipment and von board equipment based on DSRC system. Thus, it is possible to provide various application services between intelligent transportation systems of road side equipment and local server, as well as it enables the local server managing the memorys of on board equipment which entry in service area thru the road side equipment.

Design and Implementation of a Protection System for the Mentally Handicapped Using a GPS Receiver and Mobile Communications (이동통신과 GPS 수신기를 이용한 지적장애인 보호 시스템의 설계 및 구현)

  • Seol, Tae-Min;Yoon, Sang-Ho;Kang, Chang-Soon
    • Journal of Information Technology Services
    • /
    • v.9 no.4
    • /
    • pp.207-217
    • /
    • 2010
  • This paper is concerned with a protection system for the mentally handicapped, which is utilizing a GPS receiver and mobile communications. The protection system consists of a location notification equipment, a location identification and management server, and a cell phone of guardian. The location notification equipment is made up of a GPS receiver, a CDMA communication module and a microprocessor. The equipment transfers the location of the mentally impaired to the location identification and management server when the handicapped gets out of a certain bound of the designated facility. The server marks the handicapped's location on the map in the server and also notifies the guardian's cell phone of the locations. With applying the proposed protection system to social welfare organizations related to the mentally handicapped, it is expected to efficiently contribute to the promotion of the handicapped's welfare.

A Robust Mutual Authentication between User Devices and Relaying Server(FIDO Server) using Certificate Authority in FIDO Environments

  • Han, Seungjin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.63-68
    • /
    • 2016
  • Recently, Biometrics is being magnified than ID or password about user authentication. However, unlike a PIN, password, and personal information there is no way to modify the exposure if it is exposed and used illegally. As FIDO(Fast IDentity Online) than existing server storing method, It stores a user's biometric information to the user device. And the user device authentication using the user's biometric information, the user equipment has been used a method to notify only the authentication result to the server FIDO. However, FIDO has no mutual authentication between the user device and the FIDO server. We use a Certificate Authority in order to mutually authenticate the user and the FIDO server. Thereby, we propose a more reliable method and compared this paper with existed methods about security analysis.

A Study on a Heat-load of IT Equipments for the Thermal Environment Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 장비 발열기준에 대한 연구)

  • Cho, Jin-Kyun;Hong, Min-Ho;Jeong, Cha-Su;Kim, Byung-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.938-943
    • /
    • 2006
  • The primary purpose of a computer room of data center and associated infrastructure is to support the operation of critical IT equipment. Traditionally, most owners of large critical data centers have been more than willing to accept a reasonable amount of computer room worker discomfort if necessary to support critical IT systems. All electrical equipment produces heat, which must be removed to prevent the equipment temperature from rising to an unacceptable level. Most information technology equipment and other equipment found in a data center or network room is air-cooled. Sizing a cooling system requires an understanding of the amount of heat produced by the equipment contained in the enclosed space, along with the heat produced by the other heat sources typically encountered.

  • PDF

Development of an USN Based Integrated Open Server System for Disaster Prevention Management (USN 기반 개방형 방재관리 통합시스템 개발)

  • Lee, Jeong-Kyoon;Lee, Ki-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.929-932
    • /
    • 2007
  • The integrated prevention of disaster management system is collected prevention of disaster data from prevention of disaster relation other systems and smart sensor in USN. This system manages fire fighting facility effectively. The relation equipment which is used in existing and network using "Open Protocols" about under using the support system which is integrated effectively as the destroyer. It connects CCTV, the sensitivity environmental sensor, automatic fire detection equipment and security equipment and air flow equipment system using Internet. The System Server was collected monitoring data at the each equipment and processing by operational scenario. It will verified the effectiveness of operational scenario and integrated prevention of disaster management system

  • PDF

A Study on an IT Converged Smart Outdoor Exercise Equipment (IT 융합형 스마트 야외체육기구 연구)

  • Ro, Kwang-Hyun;An, Jae-Sung;Kim, Sang-Hoon;Seo, Jeong-Min;Shin, Myeong-Guk;Lee, Gunn-Yeong;Kim, Dong-Sik;Lee, Kyung-Hun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.874-875
    • /
    • 2016
  • This paper proposes the architecture and major functionalities of IT converged smart outdoor exercise equipment and health cashback system. It provides basic information such as date, time, weather information, and display the amount of exercise, thermal images for monitoring the change of user's body temperature and health cashback point. The amount of exercise is transferred to a health cashback server via mobile communication network and the server provides the exercise history and health cashback point. Also, as additional public services, a fine dust alarm light and an emergency alarm function are embedded. The proposed IT converged smart outdoor exercise equipment will be a reference model for studying and commercializing the next generation product.

A Design of Client BBS System for Secure HVA

  • Park, Jae-Kyung;Kim, Young-Ja
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.9
    • /
    • pp.73-80
    • /
    • 2018
  • In this paper, we propose a new type of client server environment to improve the architecture vulnerable to hacking in an existing client server environment. On the server side, move the existing Web server to the client side and This is a way for clients to communicate only the data they need and suggests a structure that completely blocks the web attack itself to the server. This can completely prevent a server from being hacked, spreading malicious code and hacking data on a server. It also presents a new paradigm that will not affect servers even if malware is infected with client PCs. This paper validates the proposed environment through BBS (Big Bad Stick) hardware in the form of USB on the client side. This study proof that secure services are provided through encryption communication with server-side security equipment, indicating that this study is a system with new security.