• 제목/요약/키워드: IS-95

검색결과 16,041건 처리시간 0.045초

CDMA 통신용 IS-95A/B, IS-95C 서비스의 Cell 확대를 위한 광중계기 연결보조장치 (IS-95C coupler for Optical repeater for Cell extension of IS-95A/B & IS-95C service)

  • 정재성;김부곤;이용국
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.39-43
    • /
    • 2001
  • A system, IS-95C coupler that combines the signals of IS-95A/B and IS-95C BTS and compensates the differences between the signals of two systems and connected to optical repeater If no IS-95C coupler exist, Optical repeater can't service of signal balanced. A system carries on combination, amplification, level modulation function of the TX signals(IS-95A/B & IS-95C) and division and level modulation function of the RX signals. Isolation satisfied above 100dB.

  • PDF

관측교통량의 통계적 분포에 의한 도로교통용량 산정 기법에 관한 연구 -이상적인 조건하의 고속도로 기본구간 대상- (The Development of Capacity Estimation Methods from Statistical Distribution of Observed Traffic Flow)

  • 김용걸;장명순
    • 대한교통학회지
    • /
    • 제13권1호
    • /
    • pp.167-183
    • /
    • 1995
  • The objective of study is to evaluate highway capaicty estimation alternative and to develop capacity from statistical distribution of observed traffic flow. Speed-Volume relation is analyzed from vehicle's headway distribution eliminating the long headway by confidence intervals 99%, 95%, 90%. Capacity estimate alternatives were evaluated from 95% , 90%, 85% level of cummulative distribution of observed hourly traffic flow adjusted to confidence intervals. The result of investigation revealed that maximum hourly rate of flow is 2, 130pcu at confidence interval of 995, 2, 233pcu at 95%, 2, 315pcu at 90% respectively. Compared to the capacity of 2, 200pcu per hour per lane used in HCM and KHCM(Korea Highway Capacity Manual), capa챠y appears to correspond to confidence interval of 95%. Using the traffic flow rate at confidence interval of 95% the maximum hourly flow rate is 2, 187pcu at 95% of cummulative volume distribution, 2, 153pcu at 90%, 2, 215pcu at 85%. The study suggests that raional capacity esimation alternative is to take the 95% of cummulative distribution of observed hourly traffic flow at 95% confidence headway interval eliminating 5% long headway.(i.e. 95-95 rule)

  • PDF

개에서 진정 평가를 위한 정량적 뇌파검사의 적용 (The Application of Quantitative Electroencephalography (Spectral Edge Frequency 95) to Evaluate Sedation in Dogs)

  • 김민수;남치주
    • 한국임상수의학회지
    • /
    • 제23권1호
    • /
    • pp.31-35
    • /
    • 2006
  • 본 연구는 건강한 12마리의 슈나우져견에서 정량적 뇌파검사를 이용하여 진정을 평가한 것이다. 뇌파검사는 뇌나 행동의 변화와 관련된 중추신경계의 변화를 객관적으로 측정하는 데 사용이 된다. 특히 정량적 뇌파검사 방법인 spectral edge frequency 95 (SEF 95)는 진정의 상태를 평가하는 효과적인 방법이다. 본 실험에서 뇌파 전극은 8곳의 각각 다른 부위의 피하에 장착 하였으며 뇌파의 원래 파형과 SEF 95로 변환된 수치를 획득하여 분석하였다. 기전이 다른 5종의 진정제를 투여 한 후 측정된 모든 실험군의 SEF 95 값이 진정제 투여 전 상태와 비교하였을 때, 유의적으로 감소한다는 것을 확인하였다. 이상의 결과로 SEF 95의 정량적인 뇌파검사는 개에서 진정 상태를 평가하는 효과적인 방법이라고 생각된다.

ON THE FAILURE OF GORENSTEINESS FOR THE SEQUENCE (1, 125, 95, 77, 70, 77, 95, 125, 1)

  • Ahn, Jeaman
    • 충청수학회지
    • /
    • 제28권4호
    • /
    • pp.537-543
    • /
    • 2015
  • In [9], the authors determine an infinite class of non-unimodal Gorenstein sequence, which includes the example $$\bar{h}_1\text{ = (1, 125, 95, 77, 71, 77, 95, 125, 1)}$$. They raise a question whether there is a Gorenstein algebra with Hilbert function $$\bar{h}_2\text{= (1, 125, 95, 77, 70, 77, 95, 125, 1)}$$, which has remained an open question. In this paper, we prove that there is no Gorenstein algebra with Hilbert function $\bar{h}_2$.

신뢰타원에 의한 삼변망의 오차해석 (Error Analysis of Trilateration Network by Confidence Ellipse)

  • 백은기;구재동
    • 한국측량학회지
    • /
    • 제13권1호
    • /
    • pp.13-20
    • /
    • 1995
  • 수평위치 결정에서 오차해석은 중요하다. 오차해석의 경우 표준오차타원이 정밀도의 척도로써 사용되나, 오차한계의 설정이나 측정치의 합격기준과 상대오차를 비교하는데 한계가 있어, 캐나다나 미국에서는 작업규정 에 95%신뢰타원을 오차한계로 설정하고 있다. 본 연구에서는 수평위치 결정시 신뢰타원을 오차해석에 적용하여 분석하였다. 최소제곱법과 오차해석이론에 대해 검토하였으며 , 컴퓨터 프로그램으로 E.D.M 삼변망에 대해 오차분석을 하였다. 본 연구결과 오차한계의 설정 , 측정치의 합격기준, 상대오차를 비교할 때 95%신뢰타원이 합리적이므로 작업규정에 95%신뢰타원을 도입하는 것이 필요하다. 또한 경제성있는 최적망 설계를 위해 측량망의 예비분석에도 95%신뢰타원이 효과적으로 적용될 수 있다고 사료된다.

  • PDF

선조질강 ESW95의 기계적 성질에 관한 연구 (Study on Mechanical Behavior of a Pre-Heat Treated Steel of ESW95)

  • 박지태;엄재근;김종훈;윤덕재;전만수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.439-443
    • /
    • 2008
  • We investigate the mechanical behavior of a pre-heat treated steel of ESW95, which is being used for automotive parts including tie-rods to save manufacturing cost and enhance product quality. SCM435 is also investigated to reveal the characteristics of the pre-heat treated steel tested. AFDEX/MAT is used to extract the true stress-strain curve over the large strain with higher accuracy. It has been found that ESW95 has very week strain-hardening behavior which can be negligible compared with SCM435 and that the initial yield strength is quite high and the toughness of ESW95 reaches nearly 75% of SCM435. ESW95 is characterized by the weak strain-hardening behavior and high yield strength that can be lead to minimization of post-processing including heat treatment and straightening. ESW95 and SCM435 are also compared by applying them to ball-stud forging by computer simulation. It is expected that a great deal of change may take place in production as well as in service if the pre-heated steels are adopted.

  • PDF

Procedural outcomes of laparoscopic caudate lobe resection: A systematic review and meta-analysis

  • Shahab Hajibandeh;Ahmed Kotb;Louis Evans;Emily Sams;Andrew Naguib;Shahin Hajibandeh;Thomas Satyadas
    • 한국간담췌외과학회지
    • /
    • 제27권1호
    • /
    • pp.6-19
    • /
    • 2023
  • A systematic review was conducted in compliance with PRISMA statement standards to identify all studies reporting outcomes of laparoscopic resection of benign or malignant lesions located in caudate lobe of liver. Pooled outcome data were calculated using random-effects models. A total of 196 patients from 12 studies were included. Mean operative time, volume of intraoperative blood loss, and length of hospital stay were 225 minutes (95% confidence interval [CI], 181-269 minutes), 134 mL (95% CI, 85-184 mL), and 7 days (95% CI, 5-9 days), respectively. The pooled risk of need for intraoperative transfusion was 2% (95% CI, 0%-5%). It was 3% (95% CI, 1%-6%) for conversion to open surgery, 6% (95% CI, 0%-19%) for need for intra-abdominal drain, 1% (95% CI, 0%-3%) for postoperative mortality, 2% (95% CI, 0%-4%) for biliary leakage, 2% (95% CI, 0%-4%) for intra-abdominal abscess, 1% (95% CI, 0%-4%) for biliary stenosis, 1% (95% CI, 0%-3%) for postoperative bleeding, 1% (95% CI, 0%-4%) for pancreatic fistula, 2% (95% CI, 1%-5%) for pulmonary complications, 1% (95% CI, 0%-4%) for paralytic ileus, and 1% (95% CI, 0%-4%) for need for reoperation. Although the available evidence is limited, the findings of the current study might be utilized for hypothesis synthesis in future studies. They can be used to inform surgeons and patients about estimated risks of perioperative complications until a higher level of evidence is available.

여과지전기영동법(濾過紙電氣泳動法)에 의한 장수명(長壽命) 핵분열(核分裂) 생성물분리(生成物分離) (Paper Electrophoretic Separation of Some Long-Lived Fission Products)

  • 이병헌;이종두
    • Journal of Radiation Protection and Research
    • /
    • 제8권2호
    • /
    • pp.15-35
    • /
    • 1983
  • 특별히 제작한 영동장치를 써서 고전압 전기영동법에 의하여 24시간 중성자 조사하고 150일 냉각한 90% 농축질산우라닐 수용액의 핵분열 생성물을 분리하였다. 핵분열생성물부터 Zr-95, Nb-95의 분리는 0.1M-$HClO_4$(pH=0.85), 0.05M-HCl+0.09M-KCl(pH=0.9), 0.1M-HCl(pH=1.1), 0.01M-HCl(pH=2.0)의 이동조건에서 가능하며 Zr-95, Nb-95는 원점부터 +1cm의 거리에서 분리된다. Zr-95와 Nb-95의 상호분리는 2% 수산암모늄을 첨가하는 경우 가능하다. 즉 0.1M-$HClO_4$, 0.05M-HCl+0.09M-KCl, 0.1M-HCl, 0.1M-식초산+0.1M- 식초산나트륨(pH=4.68)의 이동조건에서 원점부터 $-6{\sim}-7cm$ 거리에서 Nb-95, $+1{\sim}-1cm$ 거리에서 Zr-95가 각각 분리된다. 핵분열생성물부터 Ru-103의 분리는 0.025M-$Na_2CO_3+0.025M-NaHCO_3(pH=10.0)$, $0.01M-Na_3PO_4(pH=11.7)$, 0.1M-NaOH(pH=13.2)의 이동조건에서 가능하며 Ru-103는 각각 원점부터 -6cm, -4cm, -3cm거리 이동한다.

  • PDF

IS-95 시스템 역방향 채널에서의 효율적인 성능평가 기법 (Efficient Performance Evaluation Method for IS-95 System)

  • 전재춘;고윤진;정미선;황인관
    • 한국통신학회논문지
    • /
    • 제27권4B호
    • /
    • pp.345-352
    • /
    • 2002
  • 본 논문에서는 백색잡음과 페이딩환경에서 IS-95 시스템 역방향의 성능을 평가하는데 있어 컴퓨터 수행시간을 개선할 수 있는 획기적인 방법을 제안하고 제안된 방법의 효율성은 샘플수의 형태로 입증된다. 현재 통신 시스템의 성능분석에 가장 많이 사용되는 MC(Monte Carlo) 시뮬레이션 기법은 낮은 에러율에서 많은 시뮬레이션 수행시간을 요구한다. 때문에 MC 방법은 컴퓨터 수행속도의 한계를 피할 수 없게 된다. 이러한 문제점을 해결하기 위해 제안된 방식인 센트랄 모멘트 기법을 IS-95 시스템 역방향에 적용하여 MC 방법에서 요구되는 데이터 샘플수보다 적은 수신신호의 N차 센트랄 모멘트로부터 이산 확률밀집함수를 얻을 수 있다. 연속된 누적확률분포 함수는 보간법을 통해 정확하게 되고 샘플수에서의 개선 효과가 입증된다.

FPGA를 이용한 CDMA 디지털 트랜시버의 구현 (Implementation of CDMA Digital Transceiver using the FPGA)

  • 이창희;이영훈
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권4호
    • /
    • pp.115-120
    • /
    • 2002
  • 본 논문은 Field Programmable Gate Array (FPGA)와 디지털 신호처리 소자를 이용한 IS-95 CDMA신호 처리기 FPGA와 고속의 ADC/DAC를 이용한 기저대역과 중간주파수(IF)의 디지털 변환기 그리고 주파수 상·하향 변환기를 구현하였다. IS-95 CDMA 채널 처리기는 짧은 PN 코드 발생기와 왈쉬 코드 발생기로 파일롯 채널의 신호를 발생시킨다. 디지털 IF는 FPGA, 디지털 송·수신 신호처리 소자와 고속의 ADC/DAC로 구성하였다. 주파수 상·하향 변환기는 필터, 믹서, 디지털 감쇠기와 PLL로 구성되어 중간주파수(IF)와 RF 주파수를 변환하였다. 이 구현된 시스템은 IS-95 CDMA 기지국 장비 등에 장착할 수 있다.

  • PDF