• Title/Summary/Keyword: IR thermometer

Search Result 10, Processing Time 0.023 seconds

Microwave Sintering Behavior and Electrical Properties of BaTiO$_3$ Ceramics (BaTiO$_3$ 세라믹의 마이크로파 소성 및 전기적 특성)

  • Bai, Kang;Kim, Ho-Gi
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.11
    • /
    • pp.1203-1211
    • /
    • 1998
  • The microwave sintered BaTiO3 samples were obtained by using the microwave sintering device which can precisely control the sintering temperature and the sinter time by using IR optical thermometer and PID temperature controller. During microwave sintering the internal temperature of samples were mesur-ed by the optical fiber thermometer to compare the sintering behaviors between microwave- and con-ventionally sintered ones. The former showed the faster rate of grain growth with sintering time and the larger grain size than the latter. Also they showed the similar pattern of dielectric properties with tem-perature changes from 2$0^{\circ}C$ to 16$0^{\circ}C$.

  • PDF

Analysis of infrared thermal image for melting processes of Co-Cr-Mo based alloy using high frequency induction casting machine (치과용 고주파 주조기를 이용한 Co-Cr-Mo계 합금 용해과정의 적외선 열화상 분석)

  • Kang, Hoo-Won;Park, Young-Sik;Hwang, In;Lee, Chang-Ho;Heo, Yong;Won, Yong-Gwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: Dental casting Co-Cr-Mo based alloys of five kinds of ingot type and two kinds of shot type were analyzed the melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: When Co-Cr-Mo based alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer and IR thermometer indicated these alloys in the crucible were set and operated. Results: The melting temperatures of alloys measuring infrared thermal image analyzer were deviated ${\pm}10^{\circ}C$ compared to those of manufacturing company. On the other hand, the melting time of alloys were differently appeared with the shape of alloys(ingot and shot type). Conclusion: The melting temperatures of dental Co-Cr-Mo based alloys were measured the degree of $1,360{\sim}1410^{\circ}C$ and the heating time with the alloys of ingot and shot type were deviated ${\pm}10sec$.

Black Body Design and Verification for Non-Uniformity Correction of Imaging Sensor and Uncertainty Analysis (영상센서의 비균일 응답특성 보정을 위한 흑체 설계 및 성능검증과 보정오차 분석)

  • Shin, Somin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.240-245
    • /
    • 2013
  • Each pixel of InfraRed(IR) sensor differently responds to IR light as time elapses or the sensor on/off operation is repeated. As a result, the quality of IR sensor image is deteriorated, and therefore NUC(Non-uniformity Correction) is periodically needed for IR sensor. In this paper, in order to perform NUC in the Satellite, on-board V-grooved blackbody is designed with a baffle so that the emissivity of black body is to be higher than 0.995 as well as the temperature deviation is less than $1^{\circ}C$ in the range of the infrared wave length from 3.3 to $5.2{\mu}m$. To check its performance, the emissivity and the surface temperature of the blackbody by TRT(Transfer Reference Thermometer) and IR Micrometer scanner are measured, respectively. From the results, black body design is verified and the uncertainty of NUC is estimated through the measurement results.

IR CHARACTERISTICS OF MOLECULAR CLOUDS IN THE REGION OF SUPERSHELL GS234-02

  • JUNG JAE HOON;LEE JUNG KYU;YOON TAE SEOG
    • Journal of The Korean Astronomical Society
    • /
    • v.30 no.1
    • /
    • pp.71-81
    • /
    • 1997
  • We have studied the IR properties of molecular clouds in the region of the supershell GS234-02 using IRAS and COBE data. The mean values of dust color temperature and optical depth at $240{\mu}m$ are derived to be $15.4\pm1.5K\; and\;9.0\pm5.7\times10^{-4}$, respectively, which agree well with those determined by Sodroski et al.(1994) for the outer Galaxy. Mean IRAS colors, $R_{12}/100= 0.074,\; R_{25}/100= 0.052,\; R_{60/100}= 0.219$, indicate that the abundance of PAHs is enhanced but other particles are nearly the same as those of the solar neighborhood. We found the anticorrelation between $R_{100/140}\;and\;R_{140/240}$. It cannot be explained by the thermal emission of traditional big grains. The anticorrelation implies that, at high ISRF, $T_{100/140}$ underestimates the equilibrium temperature, while $T_{140/240}$ overestimates it and, at low ISRF, vice versa. Therefore we propose to use the intensity ratio, $R_{100/240}$ as a dust thermometer.

  • PDF

Ion Flux Assisted PECVD of SiON Films Using Plasma Parameters and Their Characterization of High Rate Deposition and Barrier Properties

  • Lee, Joon-S.;Jin, Su-B.;Choi, Yoon-S.;Choi, In-S.;Han, Jeon-G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.236-236
    • /
    • 2011
  • Silicon oxynitride (SiON) was deposited for gas barrier film on polyethylene terephthalate (PET) using octamethylycyclodisiloxane (Si4O4C8H24, OMCTS) precursor by plasma enhanced chemical vapor deposition (PECVD) at low temperature. The ion flux and substrate temperature were measured by oscilloscope and thermometer. The chemical bonding structure and barrier property of films were characterized by Fourier transform infrared (FT-IR) spectroscopy and the water vapor transmission rate (WVTR), respectively. The deposition rate of films increases with RF bias and nitrogen dilution due to increase of dissociated precursor and nitrogen ion incident to the substrate. In addition, we confirmed that the increase of nitrogen dilution and RF bias reduced WVTR of films. Because, on the basis of FT-IR analysis, the increase of the nitrogen gas flow rate and RF bias caused the increase of the C=N stretching vibration resulting in the decrease of macro and nano defects.

  • PDF

A 8-bit 10-MSample/s Folding & Interpolation ADC using Preamplifier Sharing Method (전치 증폭기 공유 기법을 이용한 8-bit 10-MSample/s Folding & Interpolation ADC)

  • Ahn, Cheol-Min;Kim, Young-Sik
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.275-283
    • /
    • 2013
  • In this paper, a 8bit 10Ms/s CMOS Folding and Interpolation analog-to-digital convertor is proposed. The architecture of the proposed ADC is based on a Folding & Interpolation using FR(Folding Rate)=8, NFB(Number of Folding Block)=4, IR(Interpolation Rate)=8. The proposed ADC adopts a preamplifier sharing method to decrease the number of preamplifier by half comparing to the conventional ones. This chip has been fabricated with a 0.35[um] CMOS technology. The effective chip area is $1.8[mm]{\times}2.11[mm]$ and it consumes 20[mA] at 3.3 power supply with 10[MHz] clock. The INL is -0.57, +0.61 [LSB] and DNL is -0.4, +0.51 [LSB]. The SFDR is 48.9[dB] and SNDR is 47.9[dB](ENOB 7.6b) when the input frequency is 100[kHz] at 10[MHz] conversion rate.

Effect of Substrate Temperature on Multi-component Particle Deposition and Consolidation in Flame Hydrolysis Deposition (화염가수분해 증착 공정에서 기판온도의 변화에 따른 다성분 입자의 부착 및 소결특성에 관한 연구)

  • Shin, Hyung-Soo;Baek, Jong-Gab;Choi, Man-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.428-433
    • /
    • 2000
  • The consolidation behavior of multicomponent particles prepared by the flame hydrolysis deposition process is examined to identify the effects of Si substrate temperature. To fabricate multi-component particles, a vapor-phase ternary mixture of $SiCl_4(100 cc/min),\;BCl_3(30cc/min)\;and\;POCl_3,(5cc/min)$ was fed into a coflow diffusion oxy-hydrogen flame burner. The doped silica soot bodies were deposited on silicon substrates under various deposition conditions. The surface temperature of the substrate was measured by an infrared thermometer. Changes in the chemical states of the doped silica soot bodies were examined by FT-IR(Fourier-transformed infrared spectroscopy). The deposited particles on the substrate were heated at $1300^{\circ}C$ for 3h in a furnace at a heating rate of 10K/min. Si-O-B bending peak has been found when surface temperature exceeds $720^{\circ}C$. Correspondingly, the case with substrate temperatures above loot produced good consolidation result.

  • PDF

Influence of Heat Stress Temperature on Sympathetic Nerve Activities (Heat-stress 온도 적용이 교감신경활동에 미치는 영향)

  • Lim, Young-Eun;Yang, Eun-Young;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.11-21
    • /
    • 2007
  • The purpose of this study were to investigate influence of heat stress temperature on sympathetic nerve activities. Subjects were 8 normal adults (4 men, 4 women, 21.36 years old). First sympathetic nerve activities were measured at the point that increase of core temperature stops at the state of applying normal thermic temperature (NIT; $34^{\circ}C$). After measurement, temperature of bathtub was increased to heat stress temperature (HST; $46^{\circ}C$) and sympathetic nerve activities were remeasured at the point that temperature increase stops. Sympathetic skin response (SSR) were analyzed using EMG, IR thermometer, and auto stethoscope. SSR latency showed significant differences at both palms by electrical stimulation to median nerve (p<.05). Electrical stimulation to forehead showed significant difference at left palm (p<.05) and electrical stimulation to navel showed significant difference at right palm (p<.05). Median nerve in changes of SSR amplitude showed significant differences at both palms in HST (p<.01). Electrical stimulation to navel showed significant difference at left palm (p<.05). Ts of forehead and xiphoid process showed significant differences (p<0.01). Tc of oral (p<0.05) and inner ear (p<0.01) showed significant differences. Pulse rate showed significant difference (<0.05). This study showed that immersion in HST had significant decrease of excitability in sympathetic nervous system compared to immersion in NTT.

  • PDF

Tool Condition Monitoring with Non-contacting Sensors in Inconel 718 Milling Processes (비접촉센서를 이용한 Inconel 718 밀링가공에서 공구상태 감시)

  • Choi, Yong-Ki;Hwang, Moon-Chang;Kim, Young-Jun;Park, Kwang-Hwi;Koo, Joon-Young;Kim, Jeong-Suk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.445-451
    • /
    • 2016
  • The Inconel 718 alloy is a well-known super-heat-resistant alloy and a difficult-to-cut material. Inconel 718 with excellent corrosion and heat resistance is used in harsh environments. However, the heat generated is not released owing to excellent physical properties, making processes (e.g., adhesion and thermal fatigue) difficult. Tool condition monitoring in machining is significant in reducing manufacturing costs. The cutting tool is easily broken and worn because of the material properties of Inconel 718. Therefore, tool management is required to improve tool life and machinability. This study proposes a method of predicting the tool wear with non-contacting sensors (e.g., IR thermometer for measuring the cutting temperature and a microphone for measuring the sound pressure level in machining). The cutting temperature and sound pressure fluctuation according to the tool condition and cutting force are analyzed using experimental data. This experiment verifies the effectiveness of the non-contact measurement signals in tool condition monitoring.

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.