• 제목/요약/키워드: IR Detector

검색결과 170건 처리시간 0.022초

적외선 탐지소자의 내방사선화 연구 (A Study on Radiation Hardening of a Infrared Detector)

  • 이남호;김승호;김영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.490-492
    • /
    • 2005
  • A study on radiation hardening of infrared(IR) detector, the chief component of IR camera was performed. The radiation test on IR sensor passivated with the ZnS by Co$^{60}$ gamma-ray over 1 Mrads showed the reduction in Ro by 1/100 which was related to the noise level. This effect that was caused by carrier trapping in the ZnS passivation layer increased the leakage current and resulted in degradation in the device performance. For the radiation hardening of IR devices we suggested the ones with CdTe passivation layer which had a tendency to reluctant to carrier trapping in its layer and developed test patterns. Radiation test to the patterns showed that the our CdTe passivated device could survived over 1 Mrad gamma-ray dose.

InSb 중적외선 검출기의 Flat-band 전압과 양자효율의 상관관계 (Relation Between Flat-band Voltage and Quantum Efficiency of InSb MWIR Detector)

  • 김영철;엄준호;정한;김선호;김남환;김영호
    • 반도체디스플레이기술학회지
    • /
    • 제17권2호
    • /
    • pp.12-15
    • /
    • 2018
  • InSb (III-V compound semiconductor) is used for photodiode to detect the mid-wavelength infrared radiation. Generally the quantum efficiency of InSb IR FPAs(Focal Plane Arrays) is known to be determined by thickness of InSb and transmittance of anti-reflection coating layer. In this study, we confirmed that the C-V characteristics of detector array affects the quantum efficiency of the InSb IR FPAs. We fabricated the IR FPAs with various $V_{fb}$(flat band voltage) values and confirmed the tendency between the $V_{fb}$ value and quantum efficiency of the IR FPAs.

Large-size LCD with touch-sensing capability

  • Zhu, X.L.;Sit, Cass K.M.;Ma, Mark W.;Feng, Y.J.;Ng, K.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1519-1522
    • /
    • 2009
  • We describe a 32" liquid-crystal display (LCD) with multi-touch sensing capability by integrating IR detector arrays onto the LED backlight plate. A transparent light guide is placed in front of the display screen, with IR LEDs disposed at its edges and emitting IR light into the light guide, the light is trapped by total internal reflection within the light guide to be as touch-sensing light. A physical contact with the acrylic plate surface will stimulate some trapped light to be escaped from the light guide and pass through LCD panel to be detected by the IR detectors. The touch-sensing LCD with this configuration can locate simultaneous multiple touche points on the touchable surface.

  • PDF

A Spatial-domain Fourier Transform Infrared Spectrometer: Application for Analyte Measurement in Cell Culture Media

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • 제9권4호
    • /
    • pp.151-156
    • /
    • 2005
  • A spatial-domain Fourier Transform (FT) infrared (IR) spectrometer coupled with a PtSi Schottky­barrier IR detector plane was developed in the spectral range of $2.0-2.5{\mu}m$ for noninvasive measurement of analyte concentrations in cell culture media during cell culture processing. A key optical component of the spectrometer is a Savart plate which is a birefringent polarizer generating coherent two rays for interfering. The spectral resolution of the spectrometer was determined as $71cm^{-1}$ (${\~}0.05{\mu}m$ at $2.5{\mu}m$). Clear IR fringe patterns were imaged on the IR detector plane. The feasibility of the spectrometer for our application was investigated by measuring absorbance spectra of glucose and fetal bovine serum (FBS) which are important compounds in cell culture media. Experiment results show that the spectral quality of glucose and FBS was comparable with the standard spectra acquired with a commercial FT-IR spectrometer, presenting the feasibility of the spectrometer to perform analyte measurement in cell culture media.

열상장비의 포화 현상에 대한 시스템 모델링 (System-Level Saturation Modeling of Thermal Imager)

  • 한승오;박승만
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.698-702
    • /
    • 2016
  • Thermal imager is now regarded as one of the key observation devices for ISR activities and getting important more and more. As other detectors, however, the thermal detectors also have maximum input and therefore they will be saturated if the input IR energy exceeds the allowed range. The saturation in the thermal detector makes it impossible to distinguish the target from background, as a result, the thermal imager does not perform its own mission anymore. In order to get an insight related with the image saturation, this paper develops a saturation model for a thermal imaging system, not a thermal detector. The proposed modeling starts from analyzing the specification of a thermal imager. Coupled with the characteristic parameters of the object, the saturation model can be used to predict the distance on which the detector is saturated. The proposed saturation model prove its validity by applying it for the case of observing a flash-bang.

소형 화기용 TEC-less 열상 처리 기법 (TEC-less Thermal Image Processing Method for Small Arms)

  • 곽동민;윤주홍;양동원;이용헌;서용석
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.162-169
    • /
    • 2019
  • This paper describes a thermal image processing algorithm for uncooled type TEC-less IR detector which is applicable to fire control system of small arms. We implemented a real-time gain and offset compensation algorithm based on polynomial approximation from the raw dataset which is acquired by two reference temperature of blackbody from various FPA(Focal Plane Array) temperature. Through the experiment, we analyzed the output characteristics of detector's raw-data and compared IR image quality to traditional non-uniformity correction method. It shows that the proposed method works well in all FPA temperature range with low residual non-uniformity.

비냉각 검출기를 이용한 소화기용 저전력 열상모듈 설계 (Low Power IR Module Design for Small Arms Using Un-cooled Type Detector)

  • 성기열;곽동민;곽기호;김도종;유준
    • 한국군사과학기술학회지
    • /
    • 제10권4호
    • /
    • pp.138-144
    • /
    • 2007
  • This paper introduces the design techniques of an IR module using the 2-D array un-cooled type infrared detector which is applied to the individual combat weapon. Considering the size and weight of the hand carried weapon system, we used a very small-sized detector and applied an adaptive temperature control algorithm so that the operation consumed with low power can be possible. We applied the AR(Auto Regressive) filter to improve the signal-to-noise ratio in a thermal image processing step. We also applied the plateau equalization and boundary enhancement techniques to improve the visibility for human visual system.

양자점 원적외선 수광소자 전망

  • 이욱현;강용훈;엄준호;홍성철;최원준;이동한;김문덕;노삼규;이정일
    • 전자공학회지
    • /
    • 제30권5호
    • /
    • pp.499-508
    • /
    • 2003
  • 실제 실험에 사용한 대표적인 InAs/GaAs QUDIP에 대해서 detector를 평가하는데 사용하는 responsitity D*뿐만 아니라 이두 값을 좌우하는 phottoconductive gain 양자효율 noise current에 대해 정량적으로 살펴보고 QWIP와 비교해보았다 우선 가장 중요한 것은 QDIP의 온도가 약 10K에서 거의 200K까지 올라가도 responsivity와 D* 모두 온도에 따라 민감하게감소하지 않는다는 사실이다(거의 10배 정도만 감소했음). 이러한 측정결과는 QDIP의 가장 큰 장점인 실온 동작 가능성이 아주 높음을 확인시켜 준다. 참고로, 이미 사용되고 있는 QWIP나 MCT detector는 낮은 온도 영역에서도 온도가 증가함에 따라 responsivity와 D*가 민감하게 감소해서 77K 이상에서는 동작하지 않는다. 두번째로, QWIP는 시료의 표면에 수직 입사되는 IR에 반응하지 않는데, QDIP는 시료의 표면에 수직 입사되는 IR에도 잘 반응함을 확인하였다. 이러한 두 가지 특성은 QDIP가 가질 것이라고 예상되던 QDIP의 가장 큰 장점으로, QDIP가 mid IR이나 far IR detector로서의 전망이 아주 밝음을 보여준다. 저온에서 QDIP의 responsivity는 수 A/W 로, 보통의 QWIP의 responsivity가 수십 mA/W인 것을 고려할 때, 충분히 큰 값이었다. QDIP의 responsivity가 이렇게 큰 이유는 photo-conductive gain이 1000 이상으로 매우 컸기 때문이었다. 반면에, 양자효율은 0.01% 이하로 아주 작았는데, 이것은 흡수 계수 자체보다는 흡수 두께가 작기 때문인 것 같고, 따라서 QDIP의 주기 수를 늘릴 필요가 있음을 알았다. Detector를 평가하는데 가장 중요한 것은 responsivity보다는 D*인데, photoconductive gain과 양자효율의 곱에 비례하는 responsivity는 $\sim$A/W로 충분히 컸지만, 반면에 D*는 $\sim$2E8으로 QWIP에 비해 작았다. 이것은 noise current가 컸기 때문이며 이를 줄이는 것이 중요하다. Noise current의 주된 요인이 dark current에 비례하는 g-r noise이므로, dark current를 줄이는 구조가 필요하다. 대표적인 예가 AlGaAs 같은 additional barrier를 넣어 dark current를 줄이는 방법이다. QDIP의 주기 수를 늘리는 것도 dark current를 줄이는 데 도움이 될 것이다.

  • PDF

복사 차폐막이 설치된 극저온 용기의 열부하 특성에 관한 실험적 연구 (An Experimental Study on the Thermal Load of a Cryochamber with Radiation Shields)

  • 김영민;강병하;박성제
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.11-16
    • /
    • 2008
  • Infrared (IR) detectors are widely used for such applications as thermoelastic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal load of a cryochamber is attributed to the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector cryochamber with a radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation.