• Title/Summary/Keyword: IPT

Search Result 147, Processing Time 0.026 seconds

Changes in the components of salivary exosomes due to initial periodontal therapy

  • Arisa Yamaguchi;Yuto Tsuruya;Kazuma Igarashi;Zhenyu Jin;Mizuho Yamazaki-Takai;Hideki Takai;Yohei Nakayama;Yorimasa Ogata
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.347-361
    • /
    • 2023
  • Purpose: Exosomes are membrane vesicles that are present in body fluids and contain proteins, lipids, and microRNA (miRNA). Periodontal tissue examinations assess the degree of periodontal tissue destruction according to the probing depth (PD), clinical attachment loss (CAL), bleeding on probing, and X-ray examinations. However, the accurate evaluation of the prognosis of periodontitis is limited. In this study, we collected saliva from patients before and after initial periodontal therapy (IPT) and compared changes in the clinical parameters of periodontitis with changes in the components of salivary exosomes. Methods: Saliva was collected from patients with stage III and IV periodontitis at the first visit and post-IPT. Exosomes were purified from the saliva, and total protein and RNA were extracted. Changes in expression levels of C6, CD81, TSG101, HSP70, and 6 kinds of miRNA were analyzed by western blots and real-time polymerase chain reaction. Results: Patients with increased C6 expression after IPT had significantly higher levels of periodontal inflamed surface area (PISA), miR-142, and miR-144 before and after IPT than patients with decreased C6 expression after IPT. Patients with decreased and unchanged CD81 expression after IPT showed significantly higher PD, CAL, and PISA before IPT than after IPT. Patients with decreased and unchanged TSG101 expression after IPT had significantly higher PD before IPT than after IPT. Patients with increased HSP70 expression after IPT had significantly higher PD and PISA before and after IPT than patients with unchanged HSP70 after IPT. The expression levels of miR-142, miR-144, miR-200b, and miR-223 changed with changes in the levels of C6, CD81, TSG101, and HSP70 in the salivary exosomes of periodontitis patients before and after IPT. Conclusions: The expression levels of proteins and miRNAs in salivary exosomes significantly changed after IPT in periodontitis patients, suggesting that the components of exosomes could serve as biomarkers for periodontitis.

A Study on the Characteristics of Small-scaled IPT System for Railway Vehicles (철도차량용 축소형 IPT 시스템의 특성 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song;Kim, Ki-Byung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1256-1257
    • /
    • 2011
  • 유도급전용 변압기(Inductive Power Transformer, IPT)는 비접촉 전력전송장치이며, 그 응용범위는 전동칫솔용 충전기, 핸드폰용 충전기와 같은 소용량 시스템뿐만 아니라, 전기자동차, 산업용 이송장치, 철도 시스템과 같은 대용량 시스템에까지 확대되고 있다. 철도시스템과 같은 교통시스템에 적용되는 IPT 시스템의 경우, 소용량 시스템과 달리 큰 공극을 가지기 때문에 높은 에너지 전달 효율을 얻기 위하여 IPT 모듈의 주의 깊은 설계가 요구되기 때문에 본 논문에서는 철도차량에 적용하기 위한 U-U 타입 IPT와 U-I 타입 IPT의 등가회로 파라미터와 커플링 계수에 대한 특성을 해석적 방법을 통하여 분석하고, 실제 20[kW] 급 IPT 시제품 모듈의 실험을 통하여 등가회로 파라미터 검증 및 IPT 모듈의 효율 계측을 수행하였다.

  • PDF

Control Method for IPT System with a Wide Range of Coupling Coefficient (넓은 결합계수 범위를 갖는 IPT 시스템의 제어방법)

  • Kim, Min-Jung;Joo, Dong-Myoung;Choi, Jun-Hyuk;Lee, Byoung Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.352-353
    • /
    • 2019
  • 자기유도 무선전력 전송 (Inductive Power Transfer, IPT) 시스템에서 송 수신패드의 결합계수 k는 송신패드와 수신패드의 이격거리에 따라 가변된다. 송 수신패드의 결합계수에 따라 IPT 컨버터의 동작특성이 바뀌기 때문에, 일반적인 스위칭 주파수 제어 방법으로는 IPT 컨버터의 정상 동작 영역이 제한된다. 본 논문에서는 송 수신패드의 결합계수 계수에 따라 풀브릿지 구조의 IPT 컨버터 1차 측을 풀브릿지 또는 하프브릿지로 제어하여 동작 가능한 결합계수 범위를 확장할 수 있는 제어 방법을 제안하고, LCCL-S 구조의 IPT 컨버터에 적용하여 실험을 통하여 제어 방법의 타당성을 검증한다.

  • PDF

Design of Active Disturbance Rejection Control for Inductive Power Transfer Systems

  • Wang, Yanan;Dong, Lei;Liao, Xiaozhong;Ju, Xinglong;Xiao, Furong
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1434-1447
    • /
    • 2018
  • The control design of inductive power transfer (IPT) systems has attracted a lot of attention in the field of wireless power transmission. Due to the high-order resonant networks and multiple loads in IPT systems, a simplified model of an IPT system is preferred for analysis and control design, and a controller with strong robustness is required. Hence, an active disturbance rejection control (ADRC) for IPT systems is proposed in this paper. To realize the employment of ADRC, firstly a small-signal model of an LC series-compensative IPT system is derived based on generalized state-space averaging (GSSA), then the ADRC is implemented in the designed IPT system. The ADRC not only provides superior robustness to unknown internal and external disturbances, but also requires few knowledge of the IPT system. Due to the convenient realization of ADRC, the designed IPT system retains its simple structure without any additional circuits. Finally, a frequency domain analysis and experimental results have validated the effectiveness of the employed ADRC, especially its robustness in the presence of frequency drifts and other common disturbances.

Characteristic of IPT coupling factor with various air-gap and winding position for PRT (PRT용 Cut core 공극 및 권선위치에 따른 IPT 결합계수 특성)

  • Han, K.H.;Lee, B.S.;Kwon, S.Y.;Park, H.J.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.223-225
    • /
    • 2007
  • The contact-less inductive power transformer (IPT) uses principle of electromagnetic induction. Generally, there were many methods to improve the transfer performance of traditional transformer. But, though the principle of IPT is similar to that of general transformer, it is impossible to apply the methods because of large air-gap. Consequently, many linear numerical formulas for analysis of performance and design of traditional transformer cannot be used in development of IPT. The concept of the IPT for vehicle like PRT(Personal Rapid Transit) system is suggested and some suggestions for power collector(core & winding) design of IPT to improve power transfer performance arc presented in this paper. The characteristic of power delivery with these novel methods in design is presented by simulation and examination.

  • PDF

A Study on the Electro-magnetic Wave of Inductive Power Transfer System for Light Railway Transit (경량전철용 유도급전 시스템의 전자파 분석 연구)

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1210-1215
    • /
    • 2012
  • Traction motors for driving and power conversion devices using semiconductor switch are equipped with a transportation systems such as an electrical railway system. Power conversion devices have the possibility of malfunction by external electromagnetic waves. As a result, these could affect the safe operation of the railway. Moreover, the electromagnetic waves above safe limits will be harmful to the passengers inside the railway vehicles or anyone working around the rail-track. For this reason, the importance and need about the reliability check and complement of electromagnetic waves generated from the IPT(Inductive Power Transfer) system have been suggested for the safe application of the IPT system to the railway system. In this study, prediction for the electromagnetic wave properties was conducted through FEM(Finite Element Method) analysis of 5kW-class IPT system design model. Next, the 5kW IPT system prototype was made and then the small-scaled railway vehicle was made to mount the IPT system and the energy management system. Finally, the electromagnetic waves generated from the real small-scaled IPT system were measured and analyzed, and then the reliability check of predictions by FEM analysis were carried out.

Output Characteristic Analysis and Design of IPT System with Semi-Bridgeless Rectifier Applying PDM Control (Semi-bridgeless 정류기를 사용한 IPT 시스템의 PDM 제어 적용에 따른 출력특성 분석 및 시스템 설계)

  • Lee, Jae Han;Son, Won-Jin;Ann, Sangjoon;Lee, Byoung Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.81-83
    • /
    • 2018
  • 본 논문에서는 inductive power transfer (IPT) 시스템 2차측 semi-bridgeless 정류기에 pulse density modulation (PDM) 제어를 적용하기 위한 시스템 설계 방안을 제안한다. LCCL-S 토폴로지를 사용한 IPT 시스템에 PDM 제어를 적용하였을 때 나타나는 출력특성을 기존의 SS 토폴로지를 사용한 시스템의 출력특성과 비교 분석한다. 분석 결과를 바탕으로, 실제 전기자동차 배터리 충전사양을 고려하여 3.3 kW 급 IPT 시스템을 설계하고 설계 결과를 시뮬레이션을 통해 검증한다.

  • PDF

High Efficiency Operation of the IPT converter with Full and Half bridge Control for Electric Vehicles (전기자동차용 IPT 컨버터의 풀브릿지-하프브릿지 제어를 통한 고효율 운전 방법)

  • Ann, Sang-Joon;Joo, Dong-Myoung;Kim, Min-Kook;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.423-430
    • /
    • 2017
  • This paper proposes a control methodology for a high efficiency operation of an inductive power transfer (IPT) converter by combining full bridge (FB) and half bridge (HB) controls. To apply the proposed control to the IPT converter, the characteristics of each control method are analyzed. By examining the output voltages of the IPT converter and a theoretical loss analysis, the control shifting points between FB and HB controls are evaluated in accordance with the coupling coefficients and the load. Based on the control shifting points, the FB-HB control algorithm is implemented. By applying FB-HB control, high efficiency operation at the light load condition can be achieved.

Knowledge and Attitudes of Indonesian General Practitioners Towards the Isoniazid Preventive Therapy Program in Indonesia

  • Winardi, Wira;Nalapraya, Widhy Yudistira;Sarifuddin, Sarifuddin;Anwar, Samsul;Yufika, Amanda;Wibowo, Adityo;Fadhil, Iziddin;Wahyuni MS, Hendra;Arliny, Yunita;Yanifitri, Dewi Behtri;Zulfikar, Teuku;Harapan, Harapan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.55 no.5
    • /
    • pp.428-435
    • /
    • 2022
  • Objectives: The Indonesian Ministry of Health launched isoniazid preventive therapy (IPT) in 2016, with general practitioners (GPs) at the frontline of this program. However, the extent to which GPs have internalized this program remains uncertain. The aim of this study was to identify the knowledge and attitudes of GPs towards the IPT program in Indonesia. Methods: This study used an online, self-administered questionnaire distributed via e-mail and social messaging services. A logistic regression model was employed to identify the explanatory variables influencing the level of knowledge and attitudes toward IPT among GPs in Indonesia. An empirical analysis was conducted separately for each response variable (knowledge and attitudes). Results: Of the 418 respondents, 128 (30.6%) had a good knowledge of IPT. Working at a public hospital was the only variable associated with good knowledge, with an adjusted odds ratio (aOR) of 1.69 (95% confidence interval [CI], 1.02 to 2.81). Furthermore, 279 respondents (66.7%) had favorable attitudes toward IPT. In the adjusted logistic regression analysis, good knowledge (aOR, 0.55; 95% CI, 0.34 to 0.89), 1-5 years of work experience (aOR, 2.09; 95% CI, 1.21 to 3.60), and having experienced IPT training (aOR, 0.48; 95% CI, 0.25 to 0.93), were significantly associated with favorable attitudes. Conclusions: In general, GPs in Indonesia had favorable attitudes toward IPT. However, their knowledge of IPT was limited. GPs are an essential element of the IPT program in the country, and therefore, adequate information dissemination to improve their understanding is critical for the long-term viability and quality of the IPT program in Indonesia.

Differentiation of Parkinson's Disease and Essential Tremor on I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy- $3{\beta}$-(4-cholorophenyl) tropane) Brain SPECT (파킨슨병과 본태성 진전의 감별진단에서 I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy-$3{\beta}$-(4-cholorophenyl) tropane) 뇌 단일광전자방출 전산화단층촬영의 역할)

  • Pai, Moon-Sun;Choi, Tae-Hyun;Ahn, Sung-Min;Choi, Jai-Yong;Ryu, Won-Gee;Lee, Jae-Hoon;Ryu, Young-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.100-106
    • /
    • 2009
  • Purpose: The study was to assess I-123-N-(3-iodopropen-2-yl)-2[beta]-carbomethoxy-3[beta]-(4-cholorophenyl) tropane(IPT) SPECT in differential diagnosis among early stage of Parkinson's disease(PD) and essential tremor(ET) and normal control(NL) groups quantitatively. Materials and Methods: I-123 IPT brain SPECT of 50 NL, 20 early PD, 30 advanced PD, and 20 ET were performed at 20 minutes and 2 hours. Specific/nonspecific binding of striatum was calculated by using right and left striatal specific to occipital non-specific uptake ratio(striatum-OCC/OCC). Results: Mean value of specific/nonspecific binding ratio was significantly different between advanced PD group and NL group. However, significant overlap of striatal specific/nonspecific binding ratio was observed between PD group and ET group. Bilateral striatal specific/nonspecific binding ratios were decreased in advanced PD. Lateralized differences in the striatal uptake of I-123 IPT correlated with asymmetry in clinical findings in PD group. Conclusion: I-123 IPT SPECT may be a useful method for the diagnosis of PD and objective evaluation of progress of clinical stages. Care should be made in the differential diagnosis of early stage of PD and other motor disturbances mimicking PD such as ET in view of significant overlap in striatal I-123 specific/nonspecific binding ratio.