• Title/Summary/Keyword: IP Controller

Search Result 210, Processing Time 0.028 seconds

Development of a Patient Monitoring System Overall Architecture and Specifications (환자모니터링시스템의 개발 : 전체구조 및 기본사양)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

Fuzzy Logic Based Buffer Management Algorithm to Improve Performance of Internet Traffic over ATM Networks (ATM 네트워크에서 인터넷 트래픽 성능 향상을 위한 퍼지기반 버퍼 관리 알고리즘)

  • 김희수;김관웅;박준성;배성환;전병실
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.9
    • /
    • pp.358-365
    • /
    • 2003
  • To support Internet traffic efficiently over ATM networks, Guaranteed Frame Rate(GFR) has been proposed in the ATM Forum. GFR provides minimum rate guarantees to VCs and allows any excess bandwidth in the network to be shared among the contending VCs in a fair manner. In this paper, we proposed a new fuzzy logic based buffer management algorithm that provides MCR guarantee and fair sharing to GFR VCs. A key feature of proposed algorithm is its ability to accept or drop a new incoming packet dynamically based on buffer condition and load ratio of VCs. This is achieved by using fuzzy logic controller for the production of a drop factor. Simulation results show that proposed scheme significantly improves fairness and TCP throughput compared with previous schemes.

Design and Implementation of a Bluetooth Baseband Module with DMA Interface (DMA 인터페이스를 갖는 블루투스 기저대역 모듈의 설계 및 구현)

  • Cheon, Ik-Jae;O, Jong-Hwan;Im, Ji-Suk;Kim, Bo-Gwan;Park, In-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.3
    • /
    • pp.98-109
    • /
    • 2002
  • Bluetooth technology is a publicly available specification proposed for Radio Frequency (RF) communication for short-range :1nd point-to-multipoint voice and data transfer. It operates in the 2.4㎓ ISM(Industrial, Scientific and Medical) band and offers the potential for low-cost, broadband wireless access for various mobile and portable devices at range of about 10 meters. In this paper, we describe the structure and the test results of the bluetooth baseband module with direct memory access method we have developed. This module consists of three blocks; link controller, UART interface, and audio CODEC. This module has a bus interface for data communication between this module and main processor and a RF interface for the transmission of bit-stream between this module and RF module. The bus interface includes DMA interface. Compared with the link controller with FIFOs, The module with DMA has a wide difference in size of module and speed of data processing. The small size module supplies lorr cost and various applications. In addition, this supports a firmware upgrade capability through UART. An FPGA and an ASIC implementation of this module, designed as soft If, are tested for file and bit-stream transfers between PCs.

Implementation of Control Point, Digital TV, and Light Controller Emulator on Embedded System Using UPnP Home Networking Control Middleware (홈 네트워킹 제어 미들웨어인 UPnP를 이용한 Control Point 및 내장형 시스템 상에서의 DTV와 전등 제어기 에뮬레이터 구현)

  • Jeon Ho-In
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.1 no.1
    • /
    • pp.6-25
    • /
    • 2002
  • In this paper, we have implemented UPnP Devices which emulate a Control Point, a Light Controller, and a Digital TV. The Control Point has been developed on Linux host system by using C language. The UPnP Devices emulating the Digital TV and Light Controller are running on embedded linux developer board. For the development of UPnP Devices, UPnP SDK API Vl.04 made by Intel Co. Ltd. has been ported on Assabet Linux Reference board to implement the UPnP protocol. After we analyze and design some services of Digital TV device, we have applied UPnP Device program to those devices. UPnP SDK vl .04 consists of APIs which support HTTP, SSDP, SOAP, GENA and XML DOM Level-1 that are cores of UPnP protocol. The C program written for the UPnP Control Point has been compiled and executed on Linux-based PC. The embedded system running on Embedded Linux OS has been connected all together through Ethernet which allows IP-based communications. Under this environment, the UPnP programs are being executed on each device. Control Point, when in operational mode, discovers UPnP Devices on the network and displays the device list on the consol. By selecting one of the functionalities of the device services that are displayed on the Control Point, the controllability has been accomplished. The experiment that we performed in this thesis have revealed that the Control Point and UPnP Devices have supported the protocols including SSDP, SOAP, GENA, and DHCP.

  • PDF

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

Flow Handover Management Scheme based on QoS in SDN Considering IoT (IoT를 고려한 SDN에서 QoS 기반 플로우 핸드오버 관리 방법)

  • Kyung, Yeun-Woong;Kim, Tae-Kook
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.2
    • /
    • pp.45-50
    • /
    • 2020
  • In this paper, we propose a QoS-based handover management scheme in SDN. Even though there have been lots of recent services such as IoT, the conventional networks provide a monolitic handover method without considerations on flow-specific QoS features. For example, the conventional Internet provides a handover method which only considers IP continuity. On the other hand, 4G and 5G networks use a strict handover method for all kinds of flows with resource reservations. This means that it is difficult to guarantee the QoS requirements for the flow with a strict QoS requirement in Internet and the inefficient resource utilization can occur in the 4G and 5G because of the strict QoS-based handover management. The proposed scheme proposes the flow handover management scheme based on QoS requirements according to the SDN controller's management. From the network operators' perspective, the proposed scheme can provide the efficient resource utilization as well as QoS provisioning.

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

Process fault diagnostics using the integrated graph model

  • Yoon, Yeo-Hong;Nam, Dong-Soo;Jeong, Chang-Wook;Yoon, En-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1705-1711
    • /
    • 1991
  • On-line fault detection and diagnosis has an increasing interest in a chemical process industry, especially for a process control and automation. The chemical process needs an intelligent operation-aided workstation which can do such tasks as process monitoring, fault detection, fault diagnosis and action guidance in semiautomatic mode. These tasks can increase the performance of a process operation and give merits in economics, safety and reliability. Aiming these tasks, series of researches have been done in our lab. Main results from these researches are building appropriate knowledge representation models and a diagnosis mechanism for fault detection and diagnosis in a chemical process. The knowledge representation schemes developed in our previous research, the symptom tree model and the fault-consequence digraph, showed the effectiveness and the usefulness in a real-time application, of the process diagnosis, especially in large and complex plants. However in our previous approach, the diagnosis speed is its demerit in spite of its merits of high resolution, mainly due to using two knowledge models complementarily. In our current study, new knowledge representation scheme is developed which integrates the previous two knowledge models, the symptom tree and the fault-consequence digraph, into one. This new model is constructed using a material balance, energy balance, momentum balance and equipment constraints. Controller related constraints are included in this new model, which possesses merits of the two previous models. This new integrated model will be tested and verified by the real-time application in a BTX process or a crude unit process. The reliability and flexibility will be greatly enhanced compared to the previous model in spite of the low diagnosis speed. Nexpert Object for the expert system shell and SUN4 workstation for the hardware platform are used. TCP/IP for a communication protocol and interfacing to a dynamic simulator, SPEEDUP, for a dynamic data generation are being studied.

  • PDF

EPICS Based Vacuum Monitoring System for PAL Storage Ring (EPICS를 이용한 가속기 진공장치 감시 시스템 개발)

  • Yoon, J.C.;Lee, J.W.;Hang, J.Y.;Nam, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2344-2346
    • /
    • 2002
  • A vacuum control system has been developed for using Ethernet Multi Serial Device Severs (EMSDS) for the Pohang Accelerator Laboratory (PAL) storage ring. There are 124 vacuum ion pumps at the storage ring. It was a very important problem to solve the problem how to control such a big number of vacuum pumps distributed around the ring. After discussions, we decided to develop a serial to ethernet interrace device sever that will be mounted in the control system rack. It has a 32-bits microprocessor embedded Linux, 12 ports RS485 (or RS232) slave interface. one channel 10/100BaseTx ethernet host port, one channel UART host port, and 16 Mbytes large memory buffer. These vacuum pumps are connected to Ion-Pump serial controllers, which chop the AC current so as to control the current in the pumps. The EMSDS connect either 100BaseTx or 10BaseT ethernet networks to asynchronous serial ports for communication with serial device. It can simultaneously control up to 12 ion-pump serial controllers. 12 EMSDS are connected to a personal computer (PC) through the network. The PC can automatically control the EMSDS by sending a set of commands through the TCP/IP network. Upon receiving a command from a PC running under Windows2000 through the network, the EMSDS communicate through the stave serial interrace ports to ion-pump controller. We added some software components on the top of EPICS (Experimental Physics and Industrial Control System) toolkit.

  • PDF

Design of a Small-Area, Low-Power, and High-Speed 128-KBit EEPROM IP for Touch-Screen Controllers (터치스크린 컨트롤러용 저면적, 저전력, 고속 128Kb EEPROMIP 설계)

  • Cho, Gyu-Sam;Kim, Doo-Hwi;Jang, Ji-Hye;Lee, Jung-Hwan;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2633-2640
    • /
    • 2009
  • We design a small-area, low-power, and high-speed EEPROM for touch screen controller IC. As a small-area EEPROM design, a SSTC (side-wall selective transistor) cell is proposed, and high-voltage switching circuits repeated in the EEPROM core circuit are optimized. A digital data-bus sensing amplifier circuit is proposed as a low-power technology. For high speed, the distributed data-bus scheme is applied, and the driving voltage for both the EEPROM cell and the high-voltage switching circuits uses VDDP (=3.3V) which is higher than the logic voltage, VDD (=1.8V), using a dual power supply. The layout size of the designed 128-KBit EEPROMIP is $662.31{\mu}m{\times}1314.89{\mu}m$.