• Title/Summary/Keyword: IEC Standard

Search Result 851, Processing Time 0.025 seconds

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Study on verification of various national standards regarding phthalate testing in industrial products (공산품 중 프탈레이트류 함유량 분석법에 관한 국내외 표준의 검증 연구)

  • Song, Moon-Hwan;Cho, Young-Dal;Choe, Eun-Kyung;Myoung, Young-Chan
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.178-189
    • /
    • 2012
  • As phthalates classified as toxic to reproduction category 2 and endocrine disrupting chemicals were more strictly regulated as Substances of Very High Concern (SVHC) for authorization in under EU REACH and considered as priority substances in RoHS II, standardization of phthalate testing method is now being proposed in IEC 62321 of IEC TC 111 and the 2nd revision of KS M 1991 is also finished. In order to assist standardization activities related to phthalating testing, solvent extraction part of existing national standards were compared and verified. Recovery of DEHP (diethylhexyl phthalate) from PVC (polyvinyl chloride) by Soxhlet extraction increased in the order of methanol, toluene, dichloromethane and hexane from 46.9% to 95.3% as measured by GC-MS. Optimum extraction time was verified to be 6 hours using hexane. Recovery of DBP (dibutyl phthalate), BBP (butylbenzyl phthalate), and DEHP from different matrixes such as PVC, nitro cellulose, ABS (acrylonitrile butadiene styrene). and EPDM(ethylene propylene diene monomer) rubber were evaluated to be more than 90% up to 99%. The detection limits of phthalates in solvent extraction followed by GC-MS analysis were 0.08~0.3 ${\mu}g/mL$ in solution and 8~30 mg/Kg in polymeric samples. GC-MS analyses of phthalates were carried out using different solvent extraction based on the EN 14372, ASTM D 7083, Japanese test method (MHLW 0906-4) and KS M 1991, proving that equivalent recoveries ranging from 98%~99% were obtained. DBP and DEHP were detected in three consumer products such as a child toy, a power cable and manicure with the amount of 22~1,910 mg/kg.

Prediction of EFT/B Signal Transfer Characteristics in Mobile Charging Circuit (모바일 충전회로에서 EFT/B 신호의 전달특성 예측에 대한 연구)

  • Song, SeungJae;Kim, Kwangho;Jo, Jeongmin;Lee, Seungbae;Kim, So-young;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.10
    • /
    • pp.895-906
    • /
    • 2015
  • This paper presents a methodology and a model that can analyze the high frequency transfer characteristics from socket in the AC power port to the 5 V DC output port in the mobile charging circuit. This is to predict the output signals coming from the IEC(International Electrotechnical Commission) Standard(IEC 61000-4-4), EFT/B(Electric Fast Transient and Burst) immunity test for mobile charging circuit. Since the mobile charging circuit is energized from the AC power socket from the power line, it is necessary to know the high frequency transfer characteristics with activated AC power line. A simple CDN(Coupling-Decoupling Network) is designed and manufactured for measuring S-parameters of mobile charging circuit with and without AC power line activated. The result shows that the S-parameters of the specific mobile charging circuits are almost the same, independent of AC power line activation. Consequently, the S-parameters without AC line could be used to predict the output response to the EFT/B signals, and it was shown that the proposed methodology predicts the output responses quite accurately, which proves the validness of the methodology presented in this paper.

Manufacturing of a Korean Hand Phantom with Human Electrical Properties at 835 MHz and 1,800 MHz Bands (835 MHz 및 1,800 MHz 대역에서 인체의 전기적 특성을 가지는 한국인 손 모양의 팬텀 제작)

  • Choi, Donggeun;Gimm, Yoonmyoung;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.534-540
    • /
    • 2013
  • Interest of the hand effect on the electromagnetic wave are internationally increasing with the increase of the use of the mobile phone. IEC TC106(International Electrotechnical Commission, Technical Committee 106) promotes international research exchange program in order to reflect the effect of human hands in the standard assessment method of human exposure dosimetry by the electromagnetic wave of mobile phones. Since current commercialized hand phantom is manufactured by taking into account the average size of westerners and provides only one grip posture, it imposes many restrictions on the accurate SAR measurement. Therefore, the development of proper hand phantom accounting for domestic situation and various grip posture capability is essential in order to analyze the accurate effect of human hand on the exposure estimation. In this paper, a jelly hand phantom suitable for Korean was manufactured with various grip posture capability at 835 MHz and 1,800 MHz bands. Although the tolerances of permittivity and conductivity of the manufactured hand phantom are with ${\pm}10%$ each, it was much less than CTIA(Cellular Telecommunication Industry Association) tolerance of ${\pm}20%$ at both bands. Its 3D CAD(3 Dimensional Computer Aided Design) file which was developed can be utilized for the simulation of human hand effect on SAR measurement of mobile phones. The findings in this study can be utilized for the analysis of human hand effect on SAR measurement of a mobile phone.

An Implementation of Gateway System for Light-weight Ethernet Interface of Engine-part's Equipments of Small Vessels (소형 선박 기관부 탑재 장비의 경량화 이더넷 인터페이스를 위한 게이트웨이 시스템의 개발)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Kim, Hyun-Woo;Shin, Il-Sik;Lee, Jang-Se
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.115-122
    • /
    • 2017
  • Recently, the on-board equipments of vessels are getting diversifications with high technologies. With changing the trends, the shipboard network is turning to the light-weight ethernet architecture for integrated data management. For that necessity, this paper covers a development of the gateway system which gathers and processes the measured analog or NMEA data from loaded equipments to convert the messages based on IEC 61162-450 (standard for light-weight ethernet network of ships) in engine parts of small vessel. To do this, we analyzed the requirements for standardization of ship's equipments and related studies. To solve the problems of existing equipments, we defined the additional data formats (sentence formatter), developed the gateway system, and verified the utility of the developed system. Consequently, we established an interfacing framework for management and application of the generated data based on the ethernet in vessel.

A Study On the Design of a Floating Point Unit for MPEG-2 AAC Decoder (MPEG-2 AAC 복호기를 위한 부동소수점유닛 설계에 관한 연구)

  • 구대성;김필중;김종빈
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.4
    • /
    • pp.355-355
    • /
    • 2002
  • In this paper, we designed a FPU(floating point unit) that it is very important and requires of high density when digital audio is designed. Almost audio system must support the multi-channel and required for high quality. A floating point arithmetic function in MPEG-2 AAC that implemented by hardware is able to realtime decoding when DSP realization. The reason is that MPEG-2 AAC is compatible to the Audio field of MPEG-4 and afterwards. We designed a FPU by hardware to increase the speed of a floating point unit with much calculation part in the MPEG-2 AAC Decoder. A FPU is composed of a multiplier and an adder. A multiplier used the Radix-4 Booth algorithm and an adder adopted 1's complement method for speed up. A form of a floating point unit has 8bit of exponent part and 24bit of mantissa. It's compatible with the IEEE single precision format and adopted a pipeline architecture to increase the speed of a processor. All of sub blocks are based on ISO/IEC 13818-7 standard. The algorithm is tested by C language and the design does by use of VHDL(VHSIC Hardware Description Language). The maximum operation speed is 23.2MHz and the stable operation speed is 19MHz.

Evaluation of Blue Light Hazards in LED Lightings (LED 조명에 대한 청색광 위험 평가)

  • Jung, Myoung Hoon;Yang, Seok-Jun;Yuk, Ju Sung;Oh, Sang-Young;Kim, Chang-Jin;Lyu, Jungmook;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.293-300
    • /
    • 2015
  • Purpose: To evaluate blue light hazards of LED lightings in an optical store with blue light radiance used as the quantitative indicators of photobiological hazard. Methods: The spectral radiance of each LED lightings was measured, and blue-light radiance and the corresponding maximum exposure time were calculated. Then each LED lighting was classified according to the risk group from IEC 62471 standard. Results: The yellow LED lightings used in showcases and white LED lightings used on ceilings and logo were classified into risk group RG0. But the white LED lightings used on showcases were classified into risk group RG1. The blue light radiances of white LED lightings used in showcases are dozens of times larger than that of fluorescent lamp. Conclusions: Using the value of the blue light radiance could quantitatively express the blue light hazard to various lightings. It was confirmed that white LED lightings for the showcases had high blue light hazards because of their high luminance and color temperature. Therefore, when replacing lightings in optical shop it is necessary to select the appropriate brightness and color temperature for eye health in the long term.

A Study on Quality Evaluation Model of Mobile Device Management for BYOD (BYOD 환경의 MDM 보안솔루션의 품질평가모델에 관한 연구)

  • Rha, HyeonDae;Kang, SuKyoung;Kim, ChangJae;Lee, NamYong
    • The Journal of Korean Association of Computer Education
    • /
    • v.17 no.6
    • /
    • pp.93-102
    • /
    • 2014
  • A mobile office environment using mobile devices, such as tablet PC, mobile phone is gradually increased in enterprises, banking and public institutions etc which is no limitation on places. It occurs advanced and persist security threats that are required effective security management policy and technical solution to be secure. For BYOD (Bring Your Own Device) environment, technical security management solutions of network control based, MDM (Mobile Device Management), MAM (Mobile Application Management), MCM (Mobile Contents Management) were released, evolved and mixed used. In perspective of integrated security management solution, mobile security product should be selected to consider user experience and environment and correct quality evaluation model of product is needed which is provided standards and guidance on the selection criteria when it was introduced. In this paper, the most widely used MDM solution is selected to take a look at its features and it was reviewed the product attributes with related international standard ISO/IEC25010 software quality attributes. And then it was derived evaluation elements and calculated the related metrics based on the quality analysis model. For the verification of quality evaluation model, security checks list and testing procedures were established; it applied metrics and analyzed the testing result through scenario based case study.

  • PDF

The study of RFID Tag read range test with RFID Emulator (RFID Emulator를 이용한 Tag 인식거리 시험 연구)

  • Joo, Hae-Jong;Kim, Young-Choon;Lee, Eu-Soo;Cho, Moon-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4536-4542
    • /
    • 2011
  • RFID technology uses communication through the use of radio waves to transfer data between a reader and an electronic tag attached to an object for the purpose of identification and tracking. RFID technology can be applied to the various service areas such as, position determination technology, remote processing management and information exchange between objects by collecting, storing, processing, and tracing their informations from the tag attached to the objects using electronic wave by recognizing the information and environment of those objects. However, to revitalize these various services, it is important to test the RFID tag performance. But There are few instructions which have and hold the RFID emulator technology for organizing the RFID international test environment. Also there are not many manufacturing companies which recognize about the exact RFID test standard and requirements for the International Standards. In this paper, a construction of Tag Performance test environments and test methods are suggested which are required by EPCglobal or ISO/IEC. Details about RFID Tag performance test items proposed by ISO/IEC FDIS 18046-3 are explained, performed RFID Tag performance test through the performing test against each measured item, and draw a result for the RFID Tag performance of International Standards.

Implementation of Improved Frame Slotted ALOHA Algorithm for Fast Tag Collection in an Active RFID System (고속 태그 수집을 위한 개선된 능동형 RFID 시스템용 프레임 Slotted ALOHA 알고리즘 구현)

  • Kim, Ji-Tae;Kang, Byeong-Gwon;Lee, Kang-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.9
    • /
    • pp.598-605
    • /
    • 2014
  • In this paper, we suggest a modified slotted ALOHA algorithm for fast tag collection in active RFID system and implement the reader and tag operation using CC2530 chip of Texas Instruments Co. to prove the performance of the proposed algorithm. In the present international standard related with active RFID including ISO/IEC 18000-7 the reader sends sleep command to each tag after successful obtaining tag's information. Meanwhile, in this paper, the tags decide to sleep after checking the second command from the reader resulting in enormously decreased tag collection time. We tested the proposed algorithm with 30 tags over the range of 0-3m and the results showed that the tag collection process was completed in 400msec at average. And 30 tags are collected in one second with 99.7% and the collection rate is 100% in 2m distance between reader and tag. The collection rates are 99.94% and 99.7% for distance 2.5m and 3m, respectively. The average collection rate is 99.91% over all range and it is concluded that the proposed algorithm is enough to apply to real fields.