• Title/Summary/Keyword: IEC 61000-3-6

Search Result 29, Processing Time 0.03 seconds

A Study on the Harmonics Effect of SVC in Electric Arc Furnace Loads

  • Kim, Kyung-Chul;Jin, Seong-Eun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.54-60
    • /
    • 2006
  • Large steel industries have time-varying nonlinear loads such as electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. The main objective of the static var compensator is to maintain the rms voltage at the point of common coupling within the limit. In this research, harmonic mitigation studies were conducted with and without the SVC, and time-varying harmonics were evaluated according to the international harmonic standards (IEC 61000-3-6 and IEEE Std. 519) using a cumulative probabilistic approach.

Harmonics Measurement of Evaluation of KJ Road Tunnel Installations (KJ 도로터널시설물의 고조파 실측 및 평가)

  • Wang, Yong-Peel;Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.87-93
    • /
    • 2011
  • Nonlinear loads including lighting fixtures generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probabilistic approach is the most commonly used method to solve time varying harmonics. In this paper the time varying harmonics of lighting loads are evaluated by international harmonic standards(IEC 61000-3-6).

A Study on Harmonics Analysis and Modelling for Distribution System (배전 시스템의 고조파 분석 및 모델링에 관한 연구)

  • Wang, Yong-Peel;Jeong, Jong-Won;Jeong, Dong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.62-68
    • /
    • 2007
  • The increasing use of power electronic equipment in distribution system has been the reason for the greater concern about a harmonic in recent time. Therefore, it is necessary for measurement and modelling to analyze a harmonic level and a transfer characteristic in distribution system. In this paper, the Point of Common Coupling (PCC) is selected to analyze harmonic characteristic of distribution system by IEC 61000-3-6. Harmonic voltage and orient were measured at the PCC of real distribution system Harmonic distribution, nonlinear load component and Total Harmonic Distortion(THD) were verified. The effective and accurate modelling of real distribution system were proved through a analysis of harmonic impedance, voltage and current under steady-state. Harmonic transfer characteristic were investigated through a analysis of harmonic voltage and current under harmonic current source.

A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the Electric Arc Furnace Loads (시간에 따라 변하는 전기로 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.9-17
    • /
    • 2006
  • Large steel industries have nonlinear loads such as electric arc furnaces. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time-varying harmonics. Harmonic simulations are performed to evaluate the harmonic voltage and current distortions throughout the system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519 and harmonic simulation for the time-varying harmonics. The EDSA program was used as a simulation tool for the case study.

A Study on the Harmonic Characteristics of GHP Cooling/Heating Load in an Institutional Building (교육용 건물의 GHP 냉/난방 부하의 고조파 특성에 관한 연구)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Lee, Kyu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.29-38
    • /
    • 2009
  • The GHP(Gas Heat Pump) is an efficient cooling;11eating system in which a compressor is driven by a gas engine and is brodening its application to the facilities such as schools and office buildings. It is difficult to control the GHP system because of slow response, big time constant and time variant system. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the GHP loads, harmonic assessment by me 61000-3-2, and harmonic simulation and harmonic filter application using EDSA program for the case study system.

Non-equal DC link Voltages in a Cascaded H-Bridge with a Selective Harmonic Mitigation-PWM Technique Based on the Fundamental Switching Frequency

  • Moeini, Amirhossein;Iman-Eini, Hossein;Najjar, Mohammad
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.106-114
    • /
    • 2017
  • In this paper, the Selective Harmonic Mitigation-PWM (SHM-PWM) method is used in single-phase and three-phase Cascaded H-Bridge (CHB) inverters in order to fulfill different power quality standards such as EN 50160, CIGRE WG 36-05, IEC 61000-3-6 and IEC 61000-2-12. Non-equal DC link voltages are used to increase the degrees of freedom for the proposed SHM-PWM technique. In addition, it will be shown that the obtained solutions become continuous and without sudden changes. As a result, the look-up tables can be significantly reduced. The proposed three-phase modulation method can mitigate up to the 50th harmonic from the output voltage, while each switch has just one switching in a fundamental period. In other words, the switching frequency of the power switches are limited to 50 Hz, which is the lowest switching frequency that can be achieved in the multilevel converters, when the optimal selective harmonic mitigation method is employed. In single-phase mode, the proposed method can successfully mitigate harmonics up to the 50th, where the switching frequency is 150 Hz. Finally, the validity of the proposed method is verified by simulations and experiments on a 9-level CHB inverter.

Development of a Surge Protective Device for Computer Network to International Standards (국제규격 대응 컴퓨터 네트워크용 서지방호장치 개발)

  • Park Dae-won;Song Jae-yong;Han Joo-sup;Kil Gyung-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.6
    • /
    • pp.1253-1259
    • /
    • 2005
  • This paper dealt with the development of surge protection devices (SPDs) that can protect high speed computer network devices from overvoltages caused by switching operations or lightning surges. The designed SPD is a form of hybrid circuit which is composed of a gas tube having large current diverting capability, high response bi-directional avalanche diodes, and fast recovery diodes to reduce insertion loss on high frequency domain. Surge protection and signal transmission characteristics of the fabricated SPD was tested according to the international standards, IEC 61000-4-5 and IEC 61643-21. From the test results, the SPD is satisfied with the international standards and the high cut-off frequency was 204 MHz. Also, the SPD showed a good performance without an insertion loss on a field test of 100 Mbps class Local Area Network.

High Power Factor Single-Phase Active Rectifier for Inverter Air-Conditioner (인버터 에어컨을 위한 고역률 단상능동정류기)

  • 정용채;권경안
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.144-151
    • /
    • 1999
  • 본 논문에서는 IEC 61000-3-2와 같은 고조파 전류 국제규제에 만족하기 위해서 인버터 에어컨을 위한 고역률 단상능동정류가(SAR) [4-6]를 적용하였다. 입력전류의 왜곡을 최소화하고 FA5331, UC3854, ML4821 등과 같은 제어IC를 적용하기 위해서 입력전압 및 전류에 대한 새롭고 적절한 검출회로를 제안하였다. 효율 및 가격의 관점에서 SAR를 인버터 에어컨에 적용하기 위한 두가지 방법이 있다. 이런 두가지 방식에 대해서 수동소자의 선정방법을 제시하였다. 결정된 소자들을 사용하여 SAR 효율의 증가 여부를 확인하기 위해서 손실분석을 행하였다. 3kW급의 이러한 두가지 방식에 대한 프로트형 SAR회로를 제작하고 실험결과를 통해서 역률제어능력을 갖는 회로의 동작과 성능을 확인하였다.

  • PDF

A Study on Development Program of Harmonic Emission Limit Assessment for Transmission System (송전계통 고조파 방출 한계 평가 프로그램 개발에 관한 연구)

  • Wang, Yong-Peel;Jeong, Jong-Won;Kim, Se-Dong;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.200-202
    • /
    • 2007
  • In recent years, equipment and network standards have been increasing in both number and complexity. Two standards that will soon be introduced to KOREA are the HV standards for assessing distorting and fluctuating loads, IEC 61000-3-6. Utility engineers, being under increasing time constraints, are turning more and more to software to quickly solve problems. This paper describes the methodology used to implement the above standards in Microsoft Excel in order to assist utility engineers to readily apply these standards in practical situations.

  • PDF

Harmonics Modelling for Distribution System (배전시스템 고조파 모델링에 관한 연구)

  • Han, Hyeng-J.;Wang, Yong-P.;Chong, Hyeng-H.;Sung, Byung-H.;Park, Hee-C.;Park, In-P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.205-207
    • /
    • 2005
  • In this paper, the Point of Common Coupling (PCC) is selected to analyze harmonic characteristic of distribution system by IEC 61000 - 3 - 6 in Electromagnetic Compatibility(EMC). Harmonic voltage and current were measured at the PCC of real distribution system. Harmonic distribution, nonlinear load component and Total Harmonic Distortion(THD) were verified by measurement. The effective and accurate modelling of real distribution system were proved through a analysis of harmonic impedance, voltage and current in steady-state. Harmonic transfer characteristic in distribution system were summarized and investigated through a analysis of harmonic voltage and harmonic current in harmonic current source.

  • PDF