• Title/Summary/Keyword: IE Technique

Search Result 137, Processing Time 0.023 seconds

Ion beam irradiation for surface modification of alignment layers in liquid crystal displays (액정 디스플레이 배향막을 위한 이온빔 표면조사에 관한 연구)

  • Oh, Byeong-Yun;Kim, Byoung-Yong;Lee, Kang-Min;Kim, Young-Hwan;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04a
    • /
    • pp.41-41
    • /
    • 2008
  • In general, polyimides (PIs) are used in alignment layers in liquid crystal displays (LCDs). The rubbing alignment technique has been widely used to align the LC molecules on the PI layer. Although this method is suitable for mass production of LCDs because of its simple process and high productivity, it has certain limitations. A rubbed PI surface includes debris left by the cloth, and the generation of electrostatic charges during the rubbing induces local defects, streaks, and a grating-like wavy surface due to nonuniform microgrooves that degrade the display resolution of computer displays and digital television. Additional washing and drying to remove the debris, and overwriting for multi-domain formation to improve the electro-optical characteristics such as the wide viewing angle, reduce the cost-effectiveness of the process. Therefore, an alternative to non-rubbing techniques without changing the LC alignment layer (i.e, PI) is proposed. The surface of LC alignment layers as a function of the ion beam (IE) energy was modified. Various pretilt angles were created on the IB-irradiated PI surfaces. After IB irradiation, the Ar ions did not change the morphology of the PI surface, indicating that the pretilt angle was not due to microgrooves. To verify the compositional behavior for the LC alignment, the chemical bonding states of the ill-irradiated PI surfaces were analyzed in detail by XPS. The chemical structure analysis showed that ability of LCs to align was due to the preferential orientation of the carbon network, which was caused by the breaking of C=O double bonds in the imide ring, parallel to the incident 18 direction. The potential of non-rubbing technology for fabricating display devices was further conformed by achieving the superior electro-optical characteristics, compared to rubbed PI.

  • PDF

Prediction of the Acoustic Performance of a Music Hall Considering the Radiation Characteristics of Korean Traditional Musical Sources (국악음원의 방사특성을 고려한 국악원의 음향 성능 예측)

  • 정철호;이정권;연철호;한찬훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.146-161
    • /
    • 2004
  • There have been always some difficulties in target setting and conditioning of acoustic performances of the Korean traditional music hall due mainly to the lack of the information on the sound radiation characteristics of Korean musical sources. In this study, the radiation characteristics of four typical Korean traditional musical sources were investigated in precision and their usage was demonstrated: The selected musical sources were Gayageum (string), Daegeum (woodwind), Jango (drum), and Pansori Chang (vocal performance). Each sound source was located at the center of a semi-anechoic chamber and the directivity was determined by the measured sound pressure levels in every 10° angular position, for both vertical and horizontal directions. The directivity pattern of Gayageum varies from a uniform to a complex pattern having many side lobes with the increase of frequency. The main radiation of Daegeum is toward the upward direction. The directivity pattern of Jango is clearly a side-oriented one and the left direction intensity is sharper than its right side at low frequencies. For the Chang, the directivity pattern change from a uniform pattern to a frontally directed one as the frequency goes high. Measured directional and spectral characteristics of traditional Korean music sources were implemented into the computation of architectural acoustic measures for the Busan National Korean Traditional Music Hall which is under construction. Parameters such as RT, SPL, C80, IE, STI were calculated at two receiver positions by using a ray tracing technique. Significant differences in the acoustic measures at receiver positions were observed between the results in using the omni-directional source and the directional one. It is thought that the suggested source data and design method can be used as a basic reference in the future acoustic design of performance halls for the Korean traditional music.

CO and C3H8 Oxidations over Supported Co3O4, Pt and Co3O4-Pt Catalysts: Effect on Their Preparation Methods and Supports, and Catalyst Deactivation (Co3O4, Pt 및 Co3O4-Pt 담지 촉매상에서 CO/C3H8 산화반응: 담체 및 제조법에 따른 영향과 촉매 비활성화)

  • Kim, Moon-Hyeon;Kim, Dong-Woo;Ham, Sung-Won
    • Journal of Environmental Science International
    • /
    • v.20 no.2
    • /
    • pp.251-260
    • /
    • 2011
  • $TiO_2$- and $SiO_2$-supported $Co_3O_4$, Pt and $Co_3O_4$-Pt catalysts have been studied for CO and $C_3H_8$ oxidations at temperatures less than $250^{\circ}C$ which is a lower limit of light-off temperatures to oxidize them during emission test cycles of gasoline-fueled automotives with TWCs (three-way catalytic converters) consisting mainly of Pt, Pd and Rh. All the catalysts after appropriate activation such as calcination at $350^{\circ}C$ and reduction at $400^{\circ}C$ exhibited significant dependence on both their preparation techniques and supports upon CO oxidation at chosen temperatures. A Pt/$TiO_2$ catalyst prepared by using an ion-exchange method (IE) has much better activity for such CO oxidation because of smaller Pt nanoparticles, compared to a supported Pt obtained via an incipient wetness (IW). Supported $Co_3O_4$-only catalysts are very active for CO oxidation even at $100^{\circ}C$, but the use of $TiO_2$ as a support and the IW technique give the best performances. These effects on supports and preparation methods were indicated for $Co_3O_4$-Pt catalysts. Based on activity profiles of CO oxidation at $100^{\circ}C$ over a physical mixture of supported Pt and $Co_3O_4$ after activation under different conditions, and typical light-off temperatures of CO and unburned hydrocarbons in common TWCs as tested for $C_3H_8$ oxidation at $250^{\circ}C$ with a Pt-exchanged $SiO_2$ catalyst, this study may offer an useful approach to substitute $Co_3O_4$ for a part of platinum group metals, particularly Pt, thereby lowering the usage of the precious metals.

Imaging Assessment of Primary Prostate Cancer, Focused on Advanced MR Imaging and PET/CT (자기공명영상과 PET/CT를 중심으로 한 전립선 암의 영상 진단)

  • Jang, Jin-Hee;Byun, Jae-Young;Kim, Min-Sung;Lee, Young-Joon;Oh, Sun-Nam;Rha, Sung-Eun;Yoo, Ie-Ryung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.89-99
    • /
    • 2008
  • Imaging assessment of prostate cancer is one of the most difficult sections of oncology imaging. Detecting, localizing and staging of the primary prostate cancer by preoperative imaging are still challenging for the radiologist. Magnetic resonance (MR) imaging provides excellent soft tissue contrast and is widely used for solid organ imaging, but results of preoperative imaging of the prostate gland with conventional MR imaging is unsatisfactory. Positron emission tomography and computed tomography (PET/CT) is the cornerstone in oncology imaging, but some limitations prohibit the assessment of primary prostate cancer with PET or PET/CT. Recent studies to overcome these insufficient accuracies of imaging evaluation of primary prostate cancers with advanced MR techniques and PET and PET/CT are reported. In this article, we review the imaging findings of prostate cancer on variable modalities, focused on MR imaging and PET/CT.

  • PDF

Design of Marine IoT Wireless Network for Building Fishing Gear Monitoring System (어구 모니터링 시스템 구축을 위한 해상 IoT 무선망 설계)

  • Kwak, Jae-Min;Kim, Se-Hoon;Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.76-83
    • /
    • 2018
  • In order to prevent overusing the fishing gear and to reduce discarded fishing gear, there is a need for a technique that can efficiently transmit the information including the type and location of the fishing gear and the user's real name to the fishing boat and the control center using IoT-based communication. In order to do this, it is necessary to be able to confirm the position information of a plurality of buoys that can be identified by the base stations on the land. In this paper, in order to service the maritime IoT communication system, we calculate the link budget between the land base station and the targets on the sea to derive the service coverage. To design a marine IoT radio network for building a fishing gear monitoring system, we calculate link budget for wireless service optimization at sea for NB-IoT using 1.8 GHz frequency band and LoRa service using 900 MHz frequency band. In addition, the link budget between the land base station and buoy, the link budget between the land base station and fishing boat are calculated and the results are analyzed.

A Comparative Study on Landscape Composition of Palace Gardens in Korea, China, Japan - Focused on Changdeokgung Palace, Summer Palace and Sento Imperial Palace - (한·중·일 궁궐정원의 경관 구성 비교 연구 - 창덕궁(昌德宮), 이화원( 頤和園), 선동어소(仙洞御所)를 중심으로 -)

  • Yoon, Sang-Jun;An, Seung-Hong;Yoon, Sung-Yung;Yeom, Sung-Jin;Park, Hee-Soung;Lee, Won-Ho
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.33 no.4
    • /
    • pp.52-64
    • /
    • 2015
  • This study was carried out investigation of characteristics palace gardens representing historical background, political and cultural identity in Korea, China, and Japan. It had been done a comparative analysis in formation, location and site layout, site composition, landscape elements and planning, landscape technique and vista for palace gardens in East asia's three countries. In order to process this study, Changdeokgung Palace in Korea, Summer Palace in China and Sento Imperial Palace in Japan were selected based on similar status. therefore it provide theoretical foundation to investigate the identity of palace gardens in three countries. Furthermore the study determined homogeneity(similarity) and heterogeneity(differentiation) of the characteristics between palace gardens in three countries through the in-depth comparative analysis in order to investigate identity of palace gardens in three countries and to present the value of Korean palace garden. Homogeneity and heterogeneity between palace gardens in three countries deducted from the study were summarized as follows; First, it shows indigenous style of Korean garden throughout adapting natural terrain without natural destruction. Second, various symbolic elements which ie reflected East asian ideologies present in the gardens. Chinese thoughts and technique were influenced in the development of palace garden in Korea and implemented in similar ways of China. Homogeneity of utilizing waterscape could be found in three countries. Lastly, Palace garden in Changdeokgung had played a role as cultural place with taste for the arts rather than representing authority of the throne. It appears to be similar in China and Japan. The reason how Korea, China and Japan established their own independent style is that each palace garden had been developed to embrace indigenous culture with introduced elements even though they were closely bound up with culture.

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.