먹는 샘물의 방사성물질 측정 및 유해성 평가 (Evaluation of Radioactive Substance and Measurement of Harmfulness in Drinking Water)

  • 조정원;이상복;남조현;노은정;백현우;이예진;이준세;최지원;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.247-252
    • /
    • 2021
  • As the number of single-person households increases, the consumption of bottled water is increasing. In addition, as the public's interest in radioactivity increases, interest in the field of living radioactivity is also increasing. Since drinking water is an essential element in our daily life, it must be safe from radioactivity. In this study, gamma radiation of drinking spring water was measured and internal exposure dose evaluation was performed to determine its harmfulness. K-40 and uranium-based radioactivity analysis was performed through a high-purity germanium detector, and as a result, drinking water was detected somewhat higher than that of mixing water. Since there is no regulation on the natural radioactivity concentration in Korea, it was compared with the U.S. Environmental Protection Agency Drinking Water Regulations and World Health Organization standard. As a result, there were some items that exceeded standards. Internal exposure was evaluated according to the effective dose formula of ICRP 119. As the result was derived that a maximum of 1.17 mSv per year could be received. This result means that the dose limit for the general public may be exceeded, and it was judged that it is necessary to set an appropriate standard value and present a recommendation value through continuous monitoring in the future.

Evaluation of Occupational, Facility and Environmental Radiological Data From the Centralized Radioactive Waste Management Facility in Accra, Ghana

  • Gustav Gbeddy;Yaw Adjei-Kyereme;Eric T. Glover;Eric Akortia;Paul Essel;Abdallah M.A. Dawood;Evans Ameho;Emmanuel Aberikae
    • 방사성폐기물학회지
    • /
    • 제21권3호
    • /
    • pp.371-381
    • /
    • 2023
  • Evaluating the effectiveness of the radiation protection measures deployed at the Centralized Radioactive Waste Management Facility in Ghana is pivotal to guaranteeing the safety of personnel, public and the environment, thus the need for this study. RadiagemTM 2000 was used in measuring the dose rate of the facility whilst the personal radiation exposure of the personnel from 2011 to 2022 was measured from the thermoluminescent dosimeter badges using Harshaw 6600 Plus Automated TLD Reader. The decay store containing scrap metals from dismantled disused sealed radioactive sources (DSRS), and low-level wastes measured the highest dose rate of 1.06 ± 0.92 µSv·h-1. The range of the mean annual average personnel dose equivalent is 0.41-2.07 mSv. The annual effective doses are below the ICRP limit of 20 mSv. From the multivariate principal component analysis biplot, all the personal dose equivalent formed a cluster, and the cluster is mostly influenced by the radiological data from the outer wall surface of the facility where no DSRS are stored. The personal dose equivalents are not primarily due to the radiation exposures of staff during operations with DSRS at the facility but can be attributed to environmental radiation, thus the current radiation protection measures at the Facility can be deemed as effective.

심장동맥 조영 검사 시 검사 조건에 따른 환자 선량 평가 (Evaluation of Radiation Dose to Patients according to the Examination Conditions in Coronary Angiography)

  • 조용인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.509-517
    • /
    • 2023
  • This study analyzed imaging conditions and exposure index through clinical information collection and dose calculation programs in coronary angiography examinations. Through this, we aim to analyze the effective dose according to examination conditions and provide basic data for dose optimization. In this study, ALARA(As Low As Reasonably Achievable)-F(Fluoroscopy), a program for evaluating the radiation dose of patients and the collected clinical data, was used. First, analysis of imaging conditions and exposure index was performed based on the data of the dose report generated after coronary angiography. Second, after evaluating organ dose according to 9 imaging directions during coronary angiography, with the LAO fixed at 30°, dose evaluation was performed according to tube voltage, tube current, number of frames, focus-skin distance, and field size. Third, the effective dose for each organ was calculated according to the tissue weighting factors presented in ICRP(International Commission on Radiological Protection) recommendations. As a result, the average sum of air kerma during coronary angiography was evaluated as 234.0±112.1 mGy, the dose-area product was 25.9±13.0 Gy·cm2, and the total fluoroscopy time was 2.5±2.0 min. Also, the organ dose tended to increase as the tube voltage, milliampere-second, number of frames, and irradiation range increased, whereas the organ dose decreased as the FSD increased. Therefore, medical radiation exposure to patients can be reduced by selecting the optimal tube voltage and field size during coronary angiography, maximizing the focal-skin distance, using the lowest tube current possible, and reducing the number of frames.

심근 핵의학 검사에서 다양한 방사성핵종 조건에 따른 내부피폭선량 평가: 몬테카를로 시뮬레이션 (Evaluation of Internal Dosimetry according to Various Radionuclides Conditions in Nuclear Medicine Myocardial Scan: Monte Carlo Simulation)

  • 이민관;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.213-218
    • /
    • 2024
  • The myocardial nuclear medicine examination is widely performed to diagnose myocardium disease using various radionuclides. Although image quality according to radionuclides has improved, the radiation exposure for target organ as well as peripheral organs should be considered. Here, the aim of this study was to evaluate absorbed dose (Gy) for peripheral organs in myocardial nuclear medicine scan from myocardium according to various scan environments based on Monte Carlo simulation. The simulation environment was modeled 5 cases, which were considered by radionuclides, number of injections, and radiodosage. In addition, the each radionuclide simulation such as distribution fraction was considered by recommended standard protocol, and the mesh computational female phantom, which is provided by International Commission on Radiological Protection (ICRP) 145, was used using the particle and heavy ion transport code system (PHITS) version 3.33. Based on the results, the closer to the myocardium, the higher the absorbed dose values. In addition, application for dual injection for radionuclides leaded to high absorbed dose compared with single injection for radionuclide. Consequently, there is difference for absorbed dose according to radionuclides, number of injections, and radiodosage. To detect the accurate diseased area, acquisition for improved image quality is crucial process by injecting radionuclides, however, we need to consider absorbed dose both target and peripheral inner organs from radionuclides in terms radiation protection for patient.

어린이 부비동 엑스선 검사에서 검사자의 갑상선 차폐 효과성에 관한 연구 (Study on the Effectiveness of Radiological Technologist's Thyroid Shielding in Pediatric Paranasal Sinus X-ray Examination)

  • 곽창교;권정택;이광제;배일환;김혜정;이소미;이도병
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.197-203
    • /
    • 2024
  • During paranasal sinus X-ray examinations in children, the radiological technologist's thyroid shield is often not implemented to shorten the examination time. This study measured the radiation exposure before and after the implementation of thyroid shielding by analyzing the difference in radiation exposure, the radiological technologist's could receive depending on the actual thyroid shielding. In the left TLD, when thyroid shielding was not performed(N), the radiation exposure dose(mSv) was 2.869 for the depth dose[Hp(10)] and 2.886 for the surface dose[H(3)], and when thyroid shielding was performed(Y), the Hp(10) was 0.033 and the H(3) was 0.034. In the right TLD, when thyroid shielding was not performed(N), the radiation exposure dose was 3.149 for Hp(10) and 3.137 for H(3), and when thyroid shielding was performed, the Hp(10) of (Y) was 0.013 and the H(3) was 0.015. The differences in the overall exposure dose measurement values are all statistically significant (p<0.05). The difference in radiation dose between when thyroid shielding was not performed and when thyroid shielding was performed was more than 99.2% in both cases, indicating a high radiation shielding rate.

치과 파노라마 촬영에서 환자의 피폭선량에 관한 연구 (A Study on the Patient Exposure Doses from the Panoramic Radiography using Dentistry)

  • 박일우;정원교;황형석;임성환;이대남;임인철;이재승;박형후;곽병준;유윤식
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.17-24
    • /
    • 2013
  • 본 연구는 파노라마 표준 촬영에서 환자의 피폭 선량을 측정하여 방사선 생물학적 위험인자를 평가하고 환자의 피폭 선량 저감화 방안을 제시하고자 하였다. 피폭 선량의 측정 오차를 최소화하기 위하여 각 OSL 선량계의 교정상수를 구하였으며 파노라마 표준 촬영에서 간접적으로 포함되는 좌 우측 수정체와 갑상선, 직접적으로 포함되는 상 하 입술, 하악골 첨부, 촬영 중심점을 대상으로 ICRP에서 권고하는 인체 모형 표준 팬텀을 이용하여 측정하였다. 측정 결과, 촬영 중심점의 선량이 $413.67{\pm}6.53{\mu}Gy$로 최대였으며 상 하 입술의 경우 각각 $217.80{\pm}2.98{\mu}Gy$, $215.33{\pm}2.61{\mu}Gy$이었다. 또한 파노라마 표준 촬영에서 간접적으로 포함되는 좌 우측 수정체의 등가선량은 각각 $30.73{\pm}2.34{\mu}Gy$, $31.87{\pm}2.50{\mu}Gy$이었으며 하악골 첨부 및 갑상선의 등가선량은 $276.73{\pm}14.43{\mu}Gy$, $162.07{\pm}4.13{\mu}Gy$이었다. 결론적으로 측정된 피폭 선량은 방사선 생물학적 효과를 유발할 수 있었으며 치과 의료기관의 파노라마 표준 촬영에서 환자의 피폭 선량에 대한 저감화 방안으로 국제기구에서 권고하고 있는 방사선 방어 원칙에 대한 정당한 해석과 제도적 뒷받침(regulation)이 필요하다. 이에 파노라마 검사에 의한 피폭 선량은 기술적 경제적 측면뿐 만 아니라 사회적 인자를 고려하여 합리적으로 용인 가능한 수준까지 최소화하기 위한 체계화된 프로토콜의 제정과 주변 결정 장기를 방어하기 위한 방사선 보호 기구에 대한 추가적 연구가 필요할 것으로 판단되었다.

가임기 여성의 유방암 토모치료 시 난소선량 평가비교 (Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy)

  • 이수형;박수연;최지민;박주영;김종석
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.337-343
    • /
    • 2014
  • 목 적 : 최근 시행되고 있는 가임기 여성의 유방암 토모치료 시 치료영역 외에서 발생되는 산란 및 누설에 의한 난소산란선량을 측정하여 평가하고자 한다. 대상 및 방법 : 인체모형팬텀(Aldorson Rando phantom, USA)을 대상으로 전산화단층영상 2.5 mm 획득 후, Tomotherapy Planning station(Tomotherapy, Inc, USA)을 이용하여 좌측 유방암 환자의 토모테라피 치료계획(Tomotherapy Helical & Tomotherapy Direct)을 수립하였다. 난소의 산량 선량 측정을 위한 측정 지점은 치료계획면적의 30 cm 아래 떨어진 골반의 좌우 위치로 직경 1.5 mm, 길이가 12mm인 저에너지용 보상필터가 들어있는 종류의 유리선량계 (GD-352M, ASAHI TECHNO GLASS CO, Japan)를 이용하여 각 5회씩 측정하여 평균하였으며, 선형지수-선량반응모델을 이용한 장기등가선량(organ equivalent dose: OED)으로 평가하였다. 결 과 : 토모 Helical 및 토모 Direct의 두 가지 방식으로 측정된 난소의 산란선량은 좌측 난소부위가 각각 평균 $64.94{\pm}0.84mGy$, $37.64{\pm}1.20mGy$이고, 우측 난소부위가 평균 $64.38{\pm}1.85mGy$, $32.96{\pm}1.11mGy$로 나타났다. 이는 토모치료 시 비교적 모니터 단위(MU)가 크고 조사 시간이 긴 토모Helical 방식이 토모Direct에 비하여 측정된 산란선량의 양이 보다 약 1.8배 높은 경향을 보였다. 결 론 : 가임기 여성의 유방암 토모테라피 시 발생하는 좌우측 난소의 산량선량은 ICRP 권고 선량이하로, 불임 및 2차 암 발생에 대한 우려 수준은 현저히 낮지만 향후 유방암 발생 연령층이 낮아지고, 토모테라피와 같이 고정밀 영상유도장치를 이용한 방사선치료가 발달할수록, 가임기 여성 환자의 난소산란선량에 대한 임상적 추적조사가 더욱 필요할 것으로 사료된다.

전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가 (Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols)

  • 남소라;손혜경;이상훈;이창래;조효민;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.173-178
    • /
    • 2006
  • 본 연구는 임상 환경에서의 전신 PET/CT 영상 획득방식 조건에서 환자가 받는 피폭선량을 Alderson 팬텀과 TLD를 이용하여 측정하는 것이었다. Philips GEMINI PET/CT에서는 $^{137}Cs$ 투과 스캔과 이와의 비교를 위한 고화질 CT 투과 스캔 및 토포그램을 각각 수행하여 각 인체 장기별 선량을 측정하였다. GE DSTe PET/CT에서는 감쇄 보정용 CT투과 스캔과 진단용 전신 CT스캔 및 토포그램 그램을 각각 수행하여 인체 내 장기별 선량을 측정하였다. 여기서 각 인체 장기는 ICRP 60에서 추천하는 장기를 참고로 선택하였다. 또한 실험에 사용한 TLD는 10 MV X선을 사용하여 교정한 후 5% 이내의 정확도를 가지는 것만 사용하였다. 그 결과 Philips GEMINI PET/CT에서의 $^{137}Cs$ 선원을 이용한 투과 스캔의 유효선량은 $0.14{\pm}0.950mSv$, 고화질 CT투과 스캔에서의 유효선량은 $29.49{\pm}1.508mSv$, 토포그램에서의 유효선량은 $0.72{\pm}0.032mSv$로 나타났다. 또한 GE DSTe PET/CT에서 감쇄보정용 CT투과 스캔의 유효선량은 $20.06{\pm}1.003mSv$, 진단용 전신 CT스캔의 유효선량은 $24.83{\pm}0.805mSv$, 토포그램의 유효선량은 $0.27{\pm}0.008mSv$로 나타났다. 임상 환경에서의 PET/CT 영상을 획득했을 시 종합 피폭은 PET영상을 획득했을 때의 유효선량을 더함으로써 평가할 수 있었다. 그 결과 Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan + PET, Topogram +high Quality CT+ PET)와 GE DSTe PET/CT (Topogram+CT attenuation map+PET, Topogram+CT for diagnosis+PET)에서 환자가 받는 총 유효선량들은 각각($7.65{\pm}0.951mSv$$37.00{\pm}1.508mSv$), ($27.12{\pm}1.003mSv,\;31.89{\pm}0.805mSv$)로 나타났다. PET/CT 영상 획득 시에 가능한 한 피폭은 적게 하면서도 진단이 가능한 화질을 유지할 수 있는 최적의 프로토콜 마련이 시급한 것으로 생각된다.

  • PDF

외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사 (Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries)

  • 장건호;양달모;성동욱;이광용;김혁주
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.276-284
    • /
    • 2008
  • 전 세계적으로 컴퓨터 단층 촬영 장치(Computed Tomography, CT)의 임상 적용이 환자의 질병의 조기 진단에 매우 중요하게 사용되고 있으며 사용 빈도 또한 매년 급증하고 있다. 새로운 종류의 CT 장치들이 병변을 조기 진단하기 위하여 개발되고 있다. 이 방사선 발생 장치에 의한 환자나 작업 종사자들의 방사선 피폭이 불가피 할 수도 있다. 국내에서는 CT 장치에 대한 구체적인 방사선 방어나 방사선 시설에 대한 구체적인 규정이 확립되어 있지 않다. 본 논문에서는 국내에서의 CT 사용시설에 대한 방사선 방어 시설과 사용 기준에 대한 규정 마련에 토대를 이루기 위하여 외국에서의 CT 장비에 대한 방사선 방어 및 방사선 차폐에 대한 규정을 조사하였다. 조사방법으로는 구글 검색을 이용한 특정 키워드 검색과 방사선 관련 업무를 수행하는 특정 웹사이트를 직접 검색하는 방법을 사용하였다. 검색결과 캐나다, 미국, 영국 등의 국가에서 국가의 실정에 맞는 가이드라인을 사용하고 있었으나, 아직 이중 에너지 CT에 대한 가이드라인은 없는 것으로 나타났다. 한국에서도 국내 실정에 적합한 CT 장비에서의 방사선 방어, 차폐, 환자나 작업종사자 및 일반인에 대한 방사선 피폭에 대한 가이드라인의 설정이 필요하다고 생각된다.

  • PDF

전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로 (Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL))

  • 이서영;김경리;하혜경;임인철;이재승;박형후;곽병준;유윤식
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 2013
  • 최근 다중검출기 CT의 보편화 된 사용으로 환자의 피폭선량이 증가하고 있다. 따라서 광자극발광선량계를 이용해 촬영 목적 부위와 주변 결정장기에 대한 환자의 피폭선량을 측정하고 그에 따른 생물학적 효과를 예측하여 저감화 방안을 제시하고자 하였다. ICRP에서 권고한 표준안을 대상으로 만들어진 인체 모형 표준 팬텀에 교정상수를 부여받은 OSD 선량계를 측정하고자 하는 좌 우 수정체, 갑상선, 촬영의 중심점, 생식선에 부착하여 각 검사 부위별 노출 조건과 동일한 상태에서 환자의 피폭 선량을 모사하였다. OSL 선량계의 평균 교정상수는 $1.0058{\pm}0.0074$이었으며 검사 부위별 주변 결정장기의 등가선량은 좌 우측 수정체의 경우 직접 피폭이 약 50mGy로 최대였으며 간접 피폭되는 경우 0.24mGy, 원거리에서는 0.005mGy미만의 기준 준위 이하로 측정되었다. 갑상선의 경우 두부 검사에서 10.89mGy로 최대였으며 흉부에서 7.75mGy, 복부 및 요추부, 골반부에서는 기준 미만이었다. 생식선의 경우 골반검사에서 21.98mGy로 최대였으며 간접 피폭되는 검사에서 기준 준위 미만에서 6.92mGy까지 피폭되었다. CT 검사에서 DRL에 대한 저감화 방법은 국제기구에서 권고하고 있는 방사선 방어 원칙에 대한 정당한 해석과 제도적 뒷받침이 필요하다. 따라서 환자의 피폭을 최소화하기 위해서는 정당성을 충족하여야 하며 환자의 피폭선량에 미치는 영향들을 체계화하고 조직의 불필요한 피폭을 최소화 하여야 한다.