• Title/Summary/Keyword: ICP analysis

Search Result 816, Processing Time 0.028 seconds

Analysis of germanium in rock and sediment by ICP/MS after ammonium bifluoride(NH4HF2) digestion (이플루오린화 암모늄 시료분해 및 ICP/MS에 의한 암석 및 퇴적물 중 게르마늄 분석)

  • Eum, Chul Hun;Choi, Won Myung
    • Analytical Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.375-380
    • /
    • 2013
  • Ammonium biflouride ($NH_4HF_2$) digestion was studied for germanium analysis in rock and sediment by inductively coupled plasma mass spectrometry (ICP/MS). QLO-1 and SDO-1 are used for reference materials from USGS. Sediment, basalt and ball clay for GeoPT were chosen as real samples. The loss of germanium in open vessel digestion was well known which can be caused by easy transformation to volatile compounds. But ammonium bifluoride digestion could suppress loss of germanium in open vessel digestion. Germanium recovery was not influenced by hydrogen peroxide with ammonium bifluoride digestion. Furthermore, the new method was simple and rapid in germanium analysis by ICP/MS. MDL(method detection limit) was 0.015 ${\mu}g/g$ and germanium recovery was 106~128%.

A Numerical Analysis on the Development of ICP Source for Large Area LCD (대면적 LCD용 ICP소스에 대한 수치 해석적 분석)

  • 이주율;이영직
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.573-576
    • /
    • 1998
  • In this paper, we analyzed electric field density and plasma condition to ICP reactor geometry structure, to generate plasma, to maintain plasma uniformity of large area LCD panel in ICP reactor also, we simulated electric field density for all kind existence current (antena and plasma current) in ICP reactor to analyze plasma antena structure

  • PDF

The discharge characteristics and ICP-AES analysis of insulators by surface deterioration (애자 표면열화에 의한 방전특성과 ICP-AES 분석)

  • Shong, Kil-Mok;Kim, Young-Seok;Jung, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1408_1409
    • /
    • 2009
  • It's described the discharge characteristics and ICP-AES analysis of insulators by surface deterioration in this paper. For the assessment of insulators, there are applied the conductivity of dusts, contact angle measurement of the insulator surfaces and the ingredient analysis in each area. Through the analysis of pollutants attached to insulators inside the tunnel, the cleaning cycle is discussed. As the results, it would be expected to the electrical safety.

  • PDF

Determination of boron in steel by HNO3-NH4HF2 digestion and ICP-MS (질산-이플루오린화암모늄 분해 및 ICP-MS에 의한 철강 중 붕소 정량에 관한 연구)

  • Choi, Won Myung;Eum, Chul Hun;Park, Ilyong
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.352-356
    • /
    • 2014
  • Various studies have been done to improve the properties of the steel by adding boron to the steel. Some studies have reported on the analysis of the boron in steel by AAS (atomic absorption spectrometry), ICP-OES(inductively coupled plasma-optical emission spectrometry), ICP-MS (inductively coupled plasma/mass spectrometry). The volatile loss of boron of steel in sample digestion and the separation procedure for avoiding matrix effect by high concentration of iron are difficulties for determination of boron in steel. The method to determine boron in steel by ICP-MS was developed without volatilization of boron in sample digestion step with $HNO_3-NH_4HF_2$ digestion method, and the additional separation process for avoiding matrix effect. Complete decomposition of steel with $HNO_3-NH_4HF_2$ digestion method, and boron determination by ICP-MS in the matrix of high concentration of iron were possible. Quantitative recoveries of boron in certified standard steel by new method in this study were 103 to 111%, and the relative standard deviation is less than 5%. The method detection limit was $1.17{\mu}g/g$.

Improvement of ICP Component Analysis System Related to Iron Oxides (산화철에 대한 ICP 성분분석체계 개선)

  • ;;;;;;;;Shigeru Tominaga
    • Resources Recycling
    • /
    • v.7 no.4
    • /
    • pp.76-80
    • /
    • 1998
  • In order to establish the ICP composition analysis system of the compotes which have been producing and using the domestic iron oxides, the Sectional Committee of Iron Oxides had organized an analysis working team. which carried out the component analysis of several samples and den discussed about thou analysis results through 1 year. At the 1st meeting, the component deviation was reduced. At the 3rd meeting, the deviation range if each company was reduced below ${\pm}$20% and it means to be improved on an analysis level with Japaness steel companies.

  • PDF

Comparison of Blood Lead Concentration Using Graphite Furnace Atomic Absorption Spectrometry (GF-AAs) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교)

  • Kang, Min-Kyung;Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.258-266
    • /
    • 2019
  • Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GF-AAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ${\pm}40%$ of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.

Determination of Germanium in Spring Waters by Inductively Coupled Plasma Mass Spectrometry (ICP-MS에 의한 지하수 중의 Germanium 분석에 관한 연구)

  • Park, Kyung Su;Song, Seong Yeon;Shim, Ue Sup;Kim, Sun Tae
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.120-124
    • /
    • 1998
  • A rapid and accurate determination method of ultra-trace amounts of germanium in spring water by ICP-MS has been developed. Mass number 74 was not only the best mass but also the smallest mass interference. Only 30% of water samples contain germanium more than $0.1{\mu}g/L$, and a few of them has organogermanium species.

  • PDF

A comparative measurement study of Pb, Cd using ICP-AES with different pretreatment methods (ICP-AES를 이용한 전처리방법에 따른 환경시료내 Pb, Cd의 측정 비교 연구)

  • 권태영;윤춘경;전지홍
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.513-520
    • /
    • 1998
  • The evaluation of uncertainty in environmental elemental analysis can be difficult because of the wide variety of analytical sample and objectives. for the specification of measured, elemetal analysis need certain method and high pretreatment technique. The sample of Pb, Cd in paddy soil and sewage sludge were analyzed by same ICP-AES, but each using four different pretreatment technique ; 0.1N HCl extraction, AB-DTPA extraction and two Mixture Acid Digestion. The four technique gave comparable results for the analysis of lead and cadmium. Concentrations determined by Mixture Acid Digestion were more higher than those by 0.1NHCI extraction and AB-DTPA extraction.

  • PDF

Analysis of Ultra Pure Sulfuric Acid for Semiconductor Using High Resolution ICP-MS (고분해능 ICP-MS를 이용한 반도체용 고순도 황산 분석)

  • Heo, Y.W.;GiI, J.I.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.311-315
    • /
    • 1998
  • Ultra trace metal impurities of high-purity sulfuric acid for semiconductor process have been determined in the concentration of lower than ppb (ng/g) level using high resolution inductively coupled plasma mass spectrometer (HR-ICP-MS).The acid samples were evaporated and concentrated by the factor of 20. No clement in the acids exceeded 1ppb level and most of the clements were determined below 10ppt (pg/g). Elements without spectral interference in mass spectrum, such as In, V, Mn, etc, were determined in the concentration of below 1 ppt level The recoveries in the range of 72% to 127.2% for 0.5 ppb spiked sample were obtained.

  • PDF

Elemental Analysis of Drinking Water with ICP/AES (ICP/AES에 의한 먹는물의 무기원소 분석)

  • Park, Kye-Hun;Shin, Hyung-Seon;Han, Cheong-Hee
    • Economic and Environmental Geology
    • /
    • v.29 no.1
    • /
    • pp.21-24
    • /
    • 1996
  • Inductively coupled plasma atomic emission spectrophotometer (ICP/AES) is a versatile modern instruments for the multi-element analysis, but quantitative analysis using ICP/AES with normal pneumatic nebulizer is not applicable for the measurement of elemental concentrations in water down to the drinkining water standard level except a few elements because of poor detection limits. However, the detection limit can be lowered enough to measure drinking water standard, if ultrasonic nebulizer and/or hydride vapor generator is attached. This method is tested with groundwater samples from Tajeon area. It is confirmed that the elemental concentrations in these samples are within the limit of drinking water standard for the most elements. However, uranium concentration is very high in some samples compared with the concentrations suggested by Environmental Protection Agency of U.S.A. There is no standard concentration level to this element in Korea and it should be prepared immediately.

  • PDF