• Title/Summary/Keyword: ICG

Search Result 82, Processing Time 0.033 seconds

Automated Tracking of Blood Vessel in ICG Retinal Image By Presumption of Feature Points (ICG 망막영상에서 특징점 추정에 의한 혈관의 자동추적)

  • Lim, Moon-Cheol;Cho, Goon-Jung;Kim, Woo-Saeng
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.04a
    • /
    • pp.902-906
    • /
    • 2000
  • 망막 혈관 구조의 분석은 망막에 관련된 환자의 진단 및 치료에 중요한 정보를 제공하기 때문에 다양한 연구가 진행되어 왔다. 본 연구에서는 ICG(IndoCyanine Green) 기술을 이용한 망막 영상의 혈관 구조를 분석하기 위해 원의 방정식으로 묘사된 혈관 영역 에너지 함수와 분기점 추정 템플릿을 사용하여 혈관의 특징점들을 추정한 후 혈관의 형체(body)를 자동으로 추적하는 동시에 분기점을 추출하는 방법을 제안한다. 전체 혈관의 자동추적과 분기점 추출을 가능하게 하는 특징점 추정 방법과 혈관 형체의 자동추적 알고리즘 및 분기점 추출 방법을 ICG 망막 영상에 적용하여 실험한 결과 만족할 만한 성능을 보였다.

  • PDF

Determination of Aflatoxin B1 in Rice, Barley, and Feed by Non-instrumental Immunochromatographic Strip-test and High Sensitive ELISA

  • Shim, Won-Bo;Kim, Jung-Sook;Kim, Ji-Young;Choi, Jin-Gil;Je, Jung-Hyun;Kuzmina, Nina Sergeevna;Eremin, Sergei Alexandrovich;Chung, Duck-Hwa
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.623-630
    • /
    • 2008
  • A non-instrumental immunochromatographic (ICG) strip-test and direct competitive enzyme-linked immunosorbent assay (DC-ELISA) for aflatoxin B1 (AFB1) determination were developed and optimized. The detection limits of ICG strip-test and DC-ELISA were 0.5 and 0.004 ng/mL, respectively, and these methods possessed a cross-reaction to aflatoxins. The results of spiked samples by both methods were coincided with the amount spiked AFB1 and the comparative analyses of 172 real samples by 2 immunoassays and high performance liquid chromatography (HPLC) showed a good agreement. Especially, the ICG strip-test is easier to perform and quicker, but less sensitivity than DC-ELISA. Both methods could analyze a high sample throughput with short time, but the sample throughput of ICG strip-test was better. Therefore, the ICG strip-test can be used as a simple, easy, non-instrumental, and fast screening technique for AFB1 determination.

Development of Immunochromatography Strip-Test Using Nanocolloidal Gold-Antibody Probe for the Rapid Detection of Aflatoxin B1 in Grain and Feed Samples

  • Shim, Won-Bo;Yang, Zheng-You;Kim, Jung-Sook;Kim, Ji-Young;Kang, Sung-Jo;Woo, Gun-Jo;Chung, Young-Chul;Eremin, Sergei A.;Chung, Duck-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.10
    • /
    • pp.1629-1637
    • /
    • 2007
  • An immunochromatography (ICG) strip test using a nanocolloidal gold-antibody probe was developed and optimized for the rapid detection of aflatoxin B1 (AFB1). A monoclonal antibody specific to AFB1 was produced from the cloned hybridoma cell (AF78), coupled with nanocolloidal gold, and distributed on the conjugate pad of the ICG strip test. The visual detection limit of the ICG strip test was 0.5 ng/ml, and this method showed a cross-reaction to aflatoxin B2, G1, and G2. In total, 172 grain and feed samples were collected and analyzed by both the ICG strip test and HPLC. The results of the ICG strip test showed a good agreement with those obtained by HPLC. These results indicated that the ICG strip test has a potential use as a rapid and cost-effective screening tool for the determination of AFB1 in real samples and could be applied to the preliminary screening of mycotoxin in food and agricultural products, generating results within 15 min without complicated steps.

Antimicrobial effect of infrared diode laser utilizing indocyanine green against Staphylococcus aureus biofilm on titanium surface (티타늄 표면에 형성한 Staphylococcus aureus 바이오필름에 대한 인도시아닌 그린을 활용한 광역학치료의 항미생물 효과)

  • Seung Gi Kim;Si-Young Lee;Jong-Bin Lee;Heung-Sik Um;Jae-Kwan Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.55-63
    • /
    • 2024
  • Purpose: This study aimed to assess the antimicrobial efficacy of an 810-nm infrared diode laser with indocyanine green (ICG) against Staphylococcus aureus on sandblasted, large grit, and acid-etched (SLA) titanium surfaces, comparing its effectiveness with alternative chemical decontamination modalities. Materials and Methods: Biofilms of S. aureus ATCC 25923 were cultured on SLA titanium disks for 48 hours. The biofilms were divided into five treatment groups: control, chlorhexidine gluconate (CHX), tetracycline (TC), ICG, and 810-nm infrared diode laser with ICG (ICG-PDT). After treatment, colony-forming units were quantified to assess surviving bacteria, and viability was confirmed through confocal laser-scanning microscope (CLSM) imaging. Results: All treated groups exhibited a statistically significant reduction in S. aureus (P < 0.05), with notable efficacy in the CHX, TC, and ICG-PDT groups (P < 0.01). While no statistical difference was observed between TC and CHX, the ICG-PDT group demonstrated superior bacterial reduction. CLSM images revealed a higher proportion of dead bacteria stained in red within the ICG-PDT groups. Conclusion: Within the limitations, ICG-PDT effectively reduced S. aureus biofilms on SLA titanium surfaces. Further investigations into alternative decontamination methods and the clinical impact of ICG-PDT on peri-implant diseases are warranted.

Development of Immunochromatography for the Rapid Detection of Listeria monocytogenes (Listeria monocytogenes 신속 검출을 위한 면역크로마토그래피법의 개발)

  • Choi, Jin-Gil;Shim, Won-Bo;Je, Jung-Hyun;Kim, Ji-Young;Lee, Kyu-Ho;Kim, Min-Gon;Ha, Sang-Do;Kim, Keun-Sung;Kim, Kwang-Yup;Kim, Cheol-Ho;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.3
    • /
    • pp.299-303
    • /
    • 2007
  • The objective of this study was the development of immunochromatography (ICG) for the rapid and accurate detection of Listeria monocytogenes. Here, monoclonal antibodies (MAb) were conjugated with 40 nm colloidal gold particles, where the conjugate was used as the detection reagent in the ICG. The ICG was composed of three pads (sample, conjugate, and absorbance pads) and one nitrocellulose membrane. The colloidal gold-MAb conjugate was applied to the conjugate pad, and the test line and control line on the membrane were treated with MAb (FKLM-3BI2-37) and anti-mouse IgG, respectively. The detection limit of the ICG was $10^{5}$ cell/mL and it showed no cross-reaction to food borne pathogens. We inoculated meat and lettuce samples with various counts of L. monocytogenes, and analyzed them by ICG. All the inoculated meat samples gave positive results after enrichment for 24 h in LEB. These results indicate that ICG was able to serve as a primary screening tool for L. monocytogenes in various foods and agricultural products within 20 min after enrichment.

Production of Monoclonal Antibody Against Listeria monocytogenes and Its Application to Immunochromatography Strip Test

  • Shim, Won-Bo;Choi, Jin-Gil;Kim, Ji-Young;Yang, Zheng-You;Lee, Kyu-Ho;Kim, Min-Gon;Ha, Sang-Do;Kim, Keun-Sung;Kim, Kwang-Yup;Kim, Cheol-Ho;Ha, Kwang-Soo;Eremin, Sergei A.;Chung, Duck-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.7
    • /
    • pp.1152-1161
    • /
    • 2007
  • An immunochromatography (ICG) strip test based on a monoclonal antibody for the rapid detection of L. monocytogenes in meat and processed-meat samples was developed in this study. A monoclonal antibody (MAb) specific to L. monocytogenes was produced from cloned hybridoma cells (FKLM-3B12-37) and used to develop an ICG strip test. The antibody showed a stronger binding to L. monocytogenes than other Listeria species, and a weak cross-reaction to S. aureus based on an ELISA. The detection limit of the ICG strip test was $10^5\;cell/ml$. In total, 116 meat and processed-meat samples were collected and analyzed using both the ICG strip test and a PCR. The ICG strip test and PCR indicated L. monocytogenes contamination in 34 and 27 meat samples, respectively. The 7 meat samples not identified as L. monocytogenes positive by the PCR were also tested using an API kit and found to be contaminated by Listeria species. In conclusion, the ICG strip test results agreed well with those obtained using the PCR and API kit. Thus, the developed ICG has potential use as a primary screening tool for L. monocytogenes in various foods and agricultural products, generating results within 20 min without complicated steps.

A Study on the Correlationship between EEG Complexity by Nonlinear Dynamics Analysis and Impedance Cardiography (비선형 동역학적 방법을 통한 뇌파 복잡도와 임피던스 심장기록법(ICG) 지표와의 상관성 연구)

  • Ryu, Jae-Min;Park, Young-Bae;Park, Young-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.2
    • /
    • pp.128-140
    • /
    • 2007
  • Purpose: We performed this study to examine the correlationship between EEG complexity and impedance cardiography data using correlation analysis. Method: This study performed on 30 healthy subjects(16 males, 14 females). Before and after natural respiration, ICG data were recorded, and EEG raw data were measured by moving windows during 15 minutes. The correlation dimension(D2) was calculated from 15 minutes data. 8 channels EEG data were analysed with 9 index of ICG data by correlation analysis. Result: 1. ACI of impedance cardiography had significant correlationship with ch.4 of EEG complexity(p=0.03). 2. VI of impedance cardiography had significant correlationship with ch.3 of EEG complexity(p=0.034) and ch.4 of EEG complexity(p=0.017). 3. HR, TFC, PEP, LVET, STR of impedance cardiography had no significant correlationship with all of 8 channel EEG complexity. Conclusions: These results suggest that nonlinear analysis of EEG and impedance cardiography have some significant correlationship. And it can make out relationship between brain system and cardiovascular system. In the future, therefore, more study of these fields are necessary.

  • PDF

Study of Optimal Conditions Affecting the Photothermal Effect and Fluorescence Characteristics of Indocyanine Green

  • Seo, Sung Hoon;Bae, Min Gyu;Park, Hyeong Ju;Ahn, Jae Sung;Lee, Joong Wook
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.554-561
    • /
    • 2021
  • Indocyanine green (ICG) is a cyanine dye that has been used in medical diagnostics based on fluorescence imaging, and in medical therapy based on the photothermal effect. It is important to systematically understand the photothermal effect and fluorescence characteristics of ICG simultaneously. By varying a number of conditions such as laser power density, laser irradiation wavelength, concentration of ICG solution, and exposure time of laser irradiation, the intensity properties of fluorescence and the temperature change induced by the photothermal effect are measured simultaneously using a charge-coupled-device camera and a thermal-imaging camera. The optimal conditions for maximizing the photothermal effect are determined, while maintaining a relatively long lifetime and high efficiency of the fluorescence for fluorescence imaging. When the concentration of ICG is approximately 50 ㎍/ml and the laser power density exceeds 1.5 W/cm2, the fluorescence lifetime is the longest and the temperature induced by the photothermal effect rapidly increases, exceeding the critical temperature sufficient to damage human cells and tissues. The findings provide useful insight into the realization of effective photothermal therapy, while also specifying the site to be treated and enabling real-time treatment monitoring.

Automatic Tracking of Retinal Vessels by Analyzing Local Feature Points in IndoCyanine Green Retinal Images (ICG 망막영상에서 국부적 특징점 분석에 의한 혈관의 자동 추적)

  • Lim, Moon-Chul;Kim, Woo-Saeng
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.3
    • /
    • pp.202-210
    • /
    • 2002
  • During the last few years, the extraction and reconstruction of the blood vessels in the medical image has been actively researched and the analysis for the retinal vessel structure has provided important information for diagnosis and remedy of the retinopathy patients. In this research, we propose the algorithm that tracks automatically the entire retinal vessel in retinal image acquired by the ICG(IndoCyanine Green) technology. This algorithm extracts contours and centers by estimating the local maxima and processing directions and detects bifurcations and junctions by comparing direction components of the local maxima from the gradient magnitude profile of each blood vessel. We present experimental results that the entire blood vessel is automatically reconstructed and is excellent in accuracy and connectivity after applying our algorithm to the ICG retinal images of patients.

A Review of Falls in the Elderly and Exercise Intervention (지팡이의 형태가 뇌졸중 환자의 보행 시 근활성도에 미치는 영향)

  • Choi, Young-Won;Jeong, Dae-Geun;Han, Jin-Tae;Lee, Myung-Hee;Kweon, Oh-Hyun;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.125-134
    • /
    • 2007
  • Purpose : This study is to determine effects of cane-shape which influenced on the change of muscle activation, gait component in hemiplegic patients caused by cerebrovascular accident. Methods : Twenty one stroke patients using T-shape cane(TCG) and twenty one stroke patients using I-shape cane(ICG) participated in this study. Surface electromyography(SEMG) of erector spinae, transvers abdominis, tibialis anterior, soleus of both side were measured during walking without cane and walking with cane. Results : The activation of tibialis anterior was significantly increased in affected side of ICG. The activation of tibialis anterior was significantly decreased in affected side of TCG. The activation of soleus was significantly increased in affected side of ICG. The activation of soleus was significantly decreased in affected side of TCG. The activation of erector spinae was significantly increased in nonaffected side of ICG and TCG. The activation of transvers abdominis was significantly increased in nonaffected side of ICG and TCG. Conclusion : From the finding of this study, it was suggested that I-shape cane increase weight bearing of affected side in hemiplegic patient. Therefore, I-shape cane can be applied to improve gait asymmetry of hemiplegic patients.

  • PDF