• Title/Summary/Keyword: I-scan

Search Result 451, Processing Time 0.028 seconds

High Performance Object Recognition with Application of the Size and Rotational Invariant Feature of the Fourier Descriptor to the 3D Information of Edges (푸리에 표현자의 크기와 회전 불변 특징을 에지에 대한 3차원 정보에 응용한 고효율의 물체 인식)

  • Wang, Shi;Chen, Hongxin;I, Jun-Ho;Lin, Haiping;Kim, Hyong-Suk;Kim, Jong-Man
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.6
    • /
    • pp.170-178
    • /
    • 2008
  • A high performance object recognition algorithm using Fourier description of the 3D information of the objects is proposed. Object boundaries contain sufficient information for recognition in most of objects. However, it is not well utilized as the key solution of the object recognition since obtaining the accurate boundary information is not easy. Also, object boundaries vary highly depending on the size or orientation of object. The proposed object recognition algorithm is based on 1) the accurate object boundaries extracted from the 3D shape which is obtained by the laser scan device, and 2) reduction of the required database using the size and rotational invariant feature of the Fourier Descriptor. Such Fourier information is compared with the database and the recognition is done by selecting the best matching object. The experiments have been done on the rich database of MPEG 7 Part B.

An Analysis of Stress Transfer Behaviors within the Necrotic Cancellous Bone following Surgical Procedures or the Management of the Osteonecrosis of the Femoral Head (대퇴골두 무혈성 괴사증의 수술적 기법 적용 후 괴사 망상골 내에서의 응력 변화 해석)

  • Kim, J.S.;Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.245-248
    • /
    • 1997
  • Operative interventions for the management of osteonecrosis of the femoral head (ONFH) include core drilling, with or without vascularized fibular bone grafting. Nevertheless, their clinical results have not been consistently satisfactory. Recently, a new surgical procedure that incorporates cementation with polymethylmethacrylate (PMMA) after core drilling has been tried clinically. In this study, a biomechanical analysis using a finite element method(FEM) was undertaken to evaluate surgical methods and their underlying surgical parameter. Our finite element models included five types. They were (1) normal model (Type I), (2) necrotic model (Type II), (3) core decompressed model (Type III). (4) fibular bone grafted model (Type IV), and (5) cemented with PMMA model (Type V). The geometric dimensions of the femur were based on digitized CT-scan data of a normal person. Various physiological loading conditions and surgical penetration depths by the core were used as mechanical variables to study their biomechanical contributions in stress transfer within the femoral head region. In addition. the peak von Mises stress(PVMS) within the necrotic cancellous bone of the femoral head was obtained. The fibular bone grafted method and cementation method provided optimal stress transfer behaviors. Here. substantial increase in the low stress level was observed when the penetration depth was extended to 0mm and 5mm from the subchondral region. Moreover, significant decrease in PVMS due to surgery was observed in the fibular bone grafted method and the cementation method when the penetration depths were extended up to 0 and 5mm from the subchondral region. The drop in PVMS was greater during toe-off than during heel-strike (57% vs. 28% in Type IV and 49% vs. 22% in Type V). Both the vascularized fibular bone grafting method (Type IV) and the new PMMA technique (Type V) appear to be very effective in providing good stress transfer and reducing the peak Von-Mises stress within the necrotic region. Overall results show that fibular bone grafting and cementation methods are quite similar. In light of above results, the new cementation method appears to be a promising surgical alternative or the treatment of ONFH. The use of PMMA for the core can be less prone to surgical complication as opposed to preparation of fibular bone graft and can achieve more immediate fixation between the core and the surrounding region.

  • PDF

Modern Medicine and Phantom Pain (현대의학과 환상통 - 이응준의 『약혼』을 중심으로)

  • Ban, Jaeyu
    • Korean Medical Education Review
    • /
    • v.13 no.1
    • /
    • pp.25-34
    • /
    • 2011
  • Modern medicine has early experienced the absence of mimesis and has been trying to replace the absence with objective grounds and experimental data. However, as medicine became science, the crisis of medicine spread more widely. Microscopic powers and violences are invisible, but individuals are powerless and vainly unable to resist. The anguish or introspection about the situation is sometimes described in stories such as An Engagement by Lee Eung Jun. An Engagement is mentioned in this article due to the writer's attitude, which shows his introspection and desire for harmony through the wounds of each trivial character. The writer is unceasingly talking about suffering people in his story and his seriousness enables readers to find his stronger sympathy over life and death than in any other medical stories. In fact, it is impossible for readers to comprehend the confusing propositions which the writer pours out, and even uncomfortable to read the story. Nevertheless, the propositions are always in contact with reality. Perhaps it is not the writer's confusing propositions that make us uncomfortable. It might be ourselves who are always alienated and starved. We can say that the characters' pains and wounds are phantom pains caused by the absence of mimesis. Since there is no affected area, their pains cannot be measured by only scientific medicine. However, the current medical profession regards objective research evidences as absolute truth and allows them to be the sole criterion. Although scientific skills such as DNA analysis and MRI scan can be the substitutes for doctors' judgment, so much of medicine is still interpersonal relationships. An Engagement. As a person promises to marry another, as all beings together in the world promise to subordinate to one another, every subject is consistently a valuable part of each other for the writer's eyes. He is aware that it is originally impossible to get engaged to the world, but he does not give up the possibility of genuine communication. In today's post-modernism society, where a large number of pathological views define the members and the world itself, endless questioning of existence and digging into pathology will be the only way to reduce the gap between individuals and their world. This article does not say that a literary work will lead the change of medical paradigm. It sprang from a desire for medical humanities to gain more interest of the medical field, where the encounter between literature and medicine is still unfamiliar, and to make medical education recognize the importance of humanities. Starting with this work, I believe that the humanities will help us to find the solution to the age of absence of mimesis and to the crisis of medicine.

Clinical Observation on C.V.A. (뇌졸중(腦卒中)에 관(關)한 임상통계적(臨床統計的) 연구(硏究))

  • Yun, Jin-Goo;Cho, Ki-Ho;Kim, Young-Suk;Lee, Kyung-Sup
    • The Journal of Internal Korean Medicine
    • /
    • v.10 no.1
    • /
    • pp.25-38
    • /
    • 1989
  • Clinical observation was done on 1092 cases of cerebrovascular disease which were confirmed by Brain CT scan in Oriental Medical Hospital in Kyung Hee Univ. from May 1987 to May 1988. Specially, clinical prognosis of 250 patients who had been hospitalized for over 4 weeks, were obserbed. The results were obtained as follows; 1. In this study, Occlusive CVD was 77.9%, Cerebral hemorrhage was 18.8%, Subarachnoid hemonhage was 0.8%. 2. The ratio of male to female was 1.4:1. In the age distribution, 60th decade, 50th decade, 40th decade, 30th's, 20th's were in order of frequency and specially 60th decade was 35.53% over 70th decade was 17.1% in ratio. 3. The most common preceding disease of CVD was hypertension (54.21%) and diabetes mellitus (19.96%) was second. 4. Almost, the duration of hospitalization was 2-4 weeks in 34.8%, within 4 weeks in 78.02%. 5. Primary attack was 75.7%, 2nd attack was 17.9%, over 3rd attack was 3.1% in ratio of recurrence. 6. The level of consciousness was Grade I in 96.4%, Grade II in 3.2%, Grade III in 1% at attack. 7. A few complications of C.V.A. were observed in the studies: pneumonia was noted frequently in 3.2%, bed sore, urinary tract infection, gastro intestinal bleeding in order of frequency. 8. The ratio of neurologic deficiency in occlusive CVD decreased from 51.9% to 29.3% in upper limb, 52.6% to 24.4% in lower limb, and that in cerebral hemorrhage decreased from 69.5% to 25% in upper limb, 50% to 20% in lower limb. 9. The ratio of left side hemiplegia to right was 1.04:1 in male, 1:1.18 in female. 10. The herb medications for C.V.A. were various Chungg-Paesagantang, Sunghanggeonggisan were used most frequently to Chungyeold, Geopung, Soongi, Haldam and Chungsimtang, the drugs for Bogiheol were used as discharge. In these oriental medical therapy of C.V.A. objective diagnosis and more various therapeutic method must be obtained through east-west medical co-operation.

  • PDF

Detection of Imprinted Quantitative Traits Loci (QTL) for Reproductive and Growth Traits in Region of IGF II Gene on fig Chromosome (돼지 염색체상의 IGF II 유전자 인접 부위에서 번식 및 성장형질에 연관된 Imprinting 양적형질 유전자 좌위(QTL)의 탐색)

  • Lee, Hakkyo
    • Korean Journal of Animal Reproduction
    • /
    • v.25 no.4
    • /
    • pp.295-304
    • /
    • 2001
  • Characterization of quantitative trait loci (QTL) was investigated in the experimental crosses between Berkshire and Yorkshire breed. A total of 525 F$_2$ progenies from 65 matting of F$_1$ Parents were produced. Phenotypic measurements included average daily gain (ADG), average back fat thickness (ABF), and loin eye area (LEA). To identify the presence of QTL for reproductive performance, birth weight (BWT) and body weight at 16 days (16DAY) were included as indirect trait. QTL segregation was deduced using 8 markers assigned to chromosome 2 (SSC2). Quantitative trait locus analyses were performed using interval mapping by regression under line-cross model. Presence of imprinting was tested under the statistical model that separated the expression of paternally and maternally inherited alleles. To set the evidence of QTL presence, significance thresholds were derived by permutation following statistical tests, respectively. Genome scan revealed significant evidence for three quantitative trait loci (QTL) affecting growth and body compositions, of which two were identified to be QTL with imprinting expression mode near the ICF II gene region. For average back fat thickness (ABF), a paternally expressed QTL was found on chromosome 2 (SSC2). A paternally expressed QTL affecting loin eye area (LEA) was found in the region of SSC2 where evidence of imprinted QTL was found for average back fat thickness (ABF). For average daily gain (ADG), QTL expressed with Mendelian mode was found on chromosome 2 (SS2). Also, QTL affecting average daily gain (ADC), was identified to be expressed with Mendelian express mode.

  • PDF

Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model

  • Kim, So-Yeun;Lee, So-Hyoun;Cho, Seong-Keun;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • PURPOSE. The accuracy of a gypsum model (GM), which was taken using a conventional silicone impression technique, was compared with that of a polyurethane model (PM), which was taken using an iTero$^{TM}$ digital impression system. MATERIALS AND METHODS. The maxillary first molar artificial tooth was selected as the reference tooth. The GMs were fabricated through a silicone impression of a reference tooth, and PMs were fabricated by a digital impression (n=9, in each group). The reference tooth and experimental models were scanned using a 3 shape convince$^{TM}$ scan system. Each GM and PM image was superimposed on the registered reference model (RM) and 2D images were obtained. The discrepancies of the points registered on the superimposed images were measured and defined as GM-RM group and PM-RM group. Statistical analysis was performed using a Student's T-test (${\alpha}=0.05$). RESULTS. A comparison of the absolute value of the discrepancy revealed a significant difference between the two groups only at the occlusal surface. The GM group showed a smaller mean discrepancy than the PM group. Significant differences in the GM-RM group and PM-RM group were observed in the margins (point a and f), mesial mid-axial wall (point b) and occlusal surfaces (point c and d). CONCLUSION. Under the conditions examined, the digitally fabricated polyurethane model showed a tendency for a reduced size in the margin than the reference tooth. The conventional gypsum model showed a smaller discrepancy on the occlusal surface than the polyurethane model.

Development of the Heuristic Attention Model Based on Analysis of Eye Movement of Elementary School Students on Discrimination task (변별과제에서 초등학생의 안구운동 분석을 통한 발견적 주의 모델 개발)

  • Shin, Won-Sub;Shin, Dong-Hoon
    • Journal of The Korean Association For Science Education
    • /
    • v.33 no.7
    • /
    • pp.1471-1485
    • /
    • 2013
  • The purpose of this study was to develop a HAM (Heuristic Attention Model) by analyzing the difference between eye movements according to the science achievement of elementary school students on discrimination task. Science achievement was graded by the results of the Korea national achievement test conducted in 2012 for a random sampling of classes. As an assessment tool to check discrimination task, two discrimination measure problems from TSPS (Test of Science Process Skill, developed in 1994) which were suitable for an eye tracking system were adopted. The subjects of this study were 20 students from the sixth grade who agreed to participate in the research. SMI was used to collect EMD (eye movement data). Experiment 3.2 and BeGaze 3.2 programs were used to plan experiments and analyze EMD. As a result, eye movements of participants in discrimination tasks varied greatly in counts and duration of fixation, first fixation duration, and dwell time, according to students' science achievement and difficulty of the problems. By the analysis of EMD, strategies of the students' problem-solving could be found. During problem solving, subjects' eye movements were affected by visual attention; bottom-up attention, top-down attention and convert attention, and aflunter attention. In conclusion, HAM was developed, and it is believed to help in the development of a science learning program for underachievers.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

A Low-Complexity Image Compression Method Which Reduces Memories Used in Multimedia Processor Implementation (멀티미디어 프로세서 구현에 사용되는 메모리를 줄이기 위한 저 복잡도의 영상 압축 알고리즘)

  • Jung Su-Woon;Kim I-Rang;Lee Dong-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.1
    • /
    • pp.9-18
    • /
    • 2004
  • This paper presents an efficient image compression method for memory reduction in multimedia processor which can be simply implemented in hardware and provides high performance. The multimedia processor, which includes processing of high-resolution images and videos, requires large memories: they are external frame memories to store frames and internal line memories for implementing some linear filters. If we can reduce those memories by adopting a simple compression method in multimedia processor, it will strengthen its cost competitiveness. There exist many standards for efficiently compressing images and videos. However, those standards are too complex for our purpose and most of them are 2-D block-based methods, which do not support raster scanned input and output. In this paper, we propose a low-complexity compression method which has good performance, can be implemented with simple hardware logic, and supports raster scan. We have adopted 1${\times}$8 Hadamard transform for simple implementation in hardware and compression efficiency. After analyzing the coefficients, we applied an adaptive thresholding and quantization. We provide some simulation results to analyze its performance and compare with the existing methods. We also provide its hardware implementation results and discuss about cost reduction effects when applied in implementing a multimedia processor.

Study on the Annealing Effect and Magnetic Properties of a Zn0.7Mn0.3O Film (열처리 효과에 따른 Zn0.7Mn0.3O박막의 자기 특성 연구)

  • Kim, Y.M.;Kim, Y.;Yoon, M.;Park, C.S.;Lee, Y.S.;Jeon, M.S.;Park, I.W.;Park, Y.J.;Lyou, Jong H.;Kim, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.4
    • /
    • pp.155-159
    • /
    • 2003
  • We report on the annealing effect and ferromagnetic characteristics of Zn$_{0.7}$Mn$_{0.3}$O film prepared by sol-gel method on the silicon (100) substrate using field emission-scanning electron microscopy (FE-SEM), energy dispersive spectroscopy (EDS), X-ray diffractometry (XRD) and superconducting quantum interference device (SQUID) magnetometry. Magnetic measurements show thatZn$_{0.7}$Mn$_{0.3}$O films exhibit ferromagnetism at 5 K revealing the coercive field of ∼110 Oe for as grown sample and 360, 1035 Oe for samples annealed at 700, 800 $^{\circ}C$, respectively. Our experimental evidence suggests that ferromagnetic precipitates of a manganese oxide may be responsible for the observed ferromagnetic behaviors of the film.he film.