• 제목/요약/키워드: Hysteresis current controller

검색결과 82건 처리시간 0.022초

A Hysteresis Current Controller for PV-Wind Hybrid Source Fed STATCOM System Using Cascaded Multilevel Inverters

  • Palanisamy, R.;Vijayakumar, K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.270-279
    • /
    • 2018
  • This paper elucidates a hysteresis current controller for enhancing the performance of static synchronous compensator (STATCOM) using cascaded H-bridge multilevel inverter. Due to the rising power demand and growing conventional generation costs a new alternative in renewable energy source is gaining popularity and recognition. A five level single phase cascaded multilevel inverter with two separated dc sources, which is energized by photovoltaic - wind hybrid energy source. The voltages across the each dc source is balanced and standardized by the proposed hysteresis current controller. The performance of STATCOM is analyzed by connecting with grid connected system, under the steady state & dynamic state. To reduce the Total Harmonic Distortion (THD) and to improve the output voltage, closed loop hysteresis current control is achieved using PLL and PI controller. The performance of the proposed system is scrutinized through various simulation results using matlab/simulink and hardware results are also verified with simulation results.

Comparative Study of PI, Fuzzy and Fuzzy tuned PI Controllers for Single-Phase AC-DC Three-Level Converter

  • Gnanavadivel, J;Senthil Kumar, N;Yogalakshmi, P
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.78-90
    • /
    • 2017
  • This paper presents the design of closed loop controllers operating a single-phase AC-DC three-level converter for improving power quality at AC mains. Closed loop inhibits outer voltage controller and inner current controller. Simulations of three level converter with three different voltage and current controller combinations such as PI-Hysteresis, Fuzzy-Hysteresis and Fuzzy tuned PI-Hysteresis are carried out in MATLAB/Simulink. Performance parameters such as input power factor and source current total harmonic distortion (THD) are considered for comparison of the three controller combinations. The fuzzy-tuned PI voltage controller with hysteresis current controller combination provides a better result, with a source-current THD of 0.93% and unity power factor without any source side filter for the three level converter. For load variations of 25% to 100%, a THD of less than 5% is obtained with a maximum value of only 1.67%. Finally, the fuzzy-tuned PI voltage with hysteresis controller combination is implemented in a Xilinx Spartan-6 XC6SLX25 FPGA board for experimental validation of power quality enhancement. A prototype 100 W, 0-24-48 V as output converter is considered for the testing of controller performance. A source-current THD of 1.351% is obtained in the experimental study with a power factor near unity. For load variations of 25% to 100%, the THD is found to be less than 5%, with a maximum value of only 2.698% in the experimental setup which matches with the simulation results.

이중밴드 히스테리시스 전류 제어 방식 (A Double Band Hysteresis Current Control Method)

  • 오원현;유창훈;신은철;박성민;노학엽;유지윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.579-583
    • /
    • 2003
  • Hysteresis controllers are intrinsically robust to system parameters, exhibit very high dynamic response and are suitable for simple implementation. But the current control using a conventional hysteresis controller has the disadvantage that high switching frequency may happen due to lack of coordination among individual hysteresis controllers of three phases. This will of course increase the switching loss. In addition, the current error is not strictly limited. So, in this paper to reduce the switching frequency, a double band hysteresis current controller is proposed. The presented control system was tested with digital simulation in the Borland C++ program and demonstrate the advantage of proposed hysteresis current controller.

  • PDF

FACTS 기기의 고조파 저감을 위한 이중밴드 히스테리시스 전류 제어에 관한 연구 (A Study on Double Band Hysteresis Current Control based on 3-Level Inverter to reduce the harmonic component in output current of FACTS devices)

  • 최원경;최정혜;김범식;신은철;이상빈;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.180-182
    • /
    • 2005
  • The current control using a conventional hysteresis controller of a STATCOM based on two level VSI (Voltage Source Inverter) has high switching frequency and variable modulation frequency. This will increase the switching loss. In addition, the current error is not strictly limited So, in this paper to reduce the switching frequency and to maintain the constant modulation frequency, a novel double band hysteresis current controller based on 3-level VSI is proposed. A conventional hysteresis current control and a novel hysteresis current control was tested with digital simulation and verified the advantage of the novel hysteresis current controller.

  • PDF

Current Controlled PWM for Multilevel Voltage-Source Inverters with Variable and Constant Switching Frequency Regulation Techniques: A Review

  • Gawande, S.P.;Ramteke, M.R.
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.302-314
    • /
    • 2014
  • Due to advancements in power electronics and inverter topologies, the current controlled multilevel voltage-source pulse width modulated (PWM) inverter is usually preferred for accurate control, quick response and high dynamic performance. A multilevel topology approach is found to be best suited for overcoming many problems arising from the use of high power converters. This paper presents a comprehensive review and comparative study of several current control (CC) techniques for multilevel inverters with a special emphasis on various approaches of the hysteresis current controller. Since the hysteresis CC technique poses a problem of variable switching frequency, a ramp-comparator controller and a predictive controller to attain constant switching frequency are described along with its quantitative comparison. Furthermore, various methods have been reviewed to achieve hysteresis current control PWM with constant switching frequency operation. This paper complies various guidelines to choose a particular method suitable for application at a given power level, switching frequency and dynamic response.

스위치드 릴럭턴스 전동기의 히스테리시스 및 PI 전류제어기 응답특성 (A Hysteresis & PI Current Controller Response Characteristic of SRM)

  • 김동희;백원식;김민회
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.25-31
    • /
    • 2007
  • 본 논문에서는 스위치드 릴럭턴스 전동기 (SRM)의 히스테리시스 및 PI 전류제어기법의 응답특성에 관해 고찰하였다. SRM의 전류제어를 위해 가장 널리 적용되는 히스테리시스 제어기법은 전류응답특성이 빠르다는 장점이 있으나, 스위칭 주파수의 가변으로 인한 소음이 단점으로 알려져 있다. SRM의 전류제어를 위해 적용되는 다른 전류 제어기법으로는 PI 전류제어기법이 있으나, 비선형적인 특성으로 인해 일반적인 전동기 제어시스템과 같이 몇몇 고정된 변수들로 제어기를 설계하기가 용이하지 않다. 본 논문에서는 제한된 범위 내에서 전동기가 구동된다는 가정하에 선형화를 통한 PI 전류제어기를 설계하였다. 1마력 SRM을 적용하여 전류제어 및 속도제어 실험을 수행하였으며, 실험을 통해 얻어진 데이터는 적용 용도에 적합한 전류제어기법 선정을 위한 참고자료가 될 것으로 사료된다.

Microprocessor-based and Modified Hysteresis Current Controller Design for BLDCM Drive

  • Lee, Sang-Wook;Ki, Gwang-Heon;Won, Jong-Soo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.25-28
    • /
    • 1989
  • This paper is to study a modified hysteresis band current control technique for keeping the fixed switching frequency. The control technique is applied to an brushless DC motor(BLDCM). This paper gives an analysis of the modified hysteresis band with isolated neutral case and the PI controller with current limiter in forward loop; their characteristics are studied by simulation. The proposed control technique is implemented by using a microprocessor-based system.

  • PDF

SVM 기반 히스테리시스 제어기를 이용한 D-STATCOM 전류 제어에 관한 연구 (A Study on Current Control using a Novel SVM-Based Hysteresis Controller in D-STATCOM)

  • 최정혜;신은철;유지윤
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.293-301
    • /
    • 2006
  • 배전급 STATCOM(Distribution-network STATic synchronous COMpensator)에 적용 가능한 공간 벡터 변조 (Space Vector Modulation, SVM) 기법을 이용한 히스테리시스 전류제어기를 제안하였다. 히스테리시스 전류제어기는 빠른 응답 특성, 쉬운 구현, 파라미터 변화에 대한 둔감성 등 많은 장점에도 불구하고 높은 스위칭 주파수와 제한되지 않는 전류 오차 때문에 스위칭 주파수에 영향을 받는 배전급 STATCOM 전류제어기로는 적합하지 않았다. 또한 전압 벡터의 인가방식에서도 뚜렷한 근거가 없어 전류오차가 제한되지 않았다. 이에 본 논문에서는 구역판별기, SVM, 그리고 외부와 내부 히스테리시스 제어기를 이용하여 높은 스위칭 주파수를 저감하고 특정 밴드 내에서 전류 오차를 줄인 개선된 SVM 기반의 히스테리시스 전류제어기를 제안하고 모의실험을 통해 제안한 기법의 유효성을 입증하였다.

가변 히스테리시스 전류제어기를 이용한 연계형 태양광 인버터의 제어 (Control of Grid-Connected Photovoltaics Inverter Using Variable Hysteresis Band Current Controller)

  • 최연옥;조금배;백형래;김시경;유권종;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.525-527
    • /
    • 1996
  • Hysteresis current control is one of the simplest techniques used to control currents for high speed drive systems, because of its simplicity of implementation, fast current control response, and inherent peak current limiting capability. However the conventional fixed-band hysteresis control has a variable switching frequency throughout the fundamental period, and consequently the load current harmonics spreaded on the wide frequency range. In this paper, a simple, novel alterative approach is proposed for a variable-hysteresis band current controller which uses feedback techniques to achieve constant switching frequency with good dynamic response. The method is easily implemented in hardware, the resultant controller is easily tuned to a particular load, and has good immunity to variation in PV parameter and dc supply voltage.

  • PDF

3레벨 비교기를 이용한 3상인버터의 개선된 히스테리시스 전류제어 기법 (An Improved Current Control Method for Three-Phase PWM Inverters Using Three-Level Comparator)

  • 문형수;한우용;이창구;신동용;김무연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1035-1037
    • /
    • 2001
  • This paper presents an improved hys- teresis current control method for three-phase PWM power inverters using 3-level comparator. Hysteresis current controller using 3-level comparator has an advantage of constant switching frequency compared with conventional hysteresis current controller. However, this method has disadvantage that the longer sampling period, the larger current error because the switching is performed without considering current error magnitude of each phase. The proposed method improves the control performance by selecting the optimum switching pattern in which the magnitudes of current errors are considered introducing space vector concept. Simulation results using Matlab/Simulink show that the proposed control method reduces current error keeping the merit of previous hysteresis current control method.

  • PDF