• Title/Summary/Keyword: Hysteresis current control

Search Result 173, Processing Time 0.032 seconds

A Hysteresis Current Controlled Resonant C-Dump Converter for Switched Reluctance Motor (스위치드 릴럭턴스 전동기 구동을 위한 히스테리시스 전류 제어형 공진형 C-Dump 컨버터)

  • Yoon, Yong-Ho;Kim, Jae-Moon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.72-78
    • /
    • 2008
  • The speed variation of SRM is fulfilled throughout a transition from chopping control to single pulse operation. (i,e., low speed to high speed operation). It is unsatisfied with performance at all operational regimes. In this paper, the operational performance of SRM can be improved by using current hysteresis control method. This method maintains a generally flat current waveform. At the high speed, the current chopping capability is lost due to the development of the back-EMF. Therefore SRM operates in single pulse mode. By using zero-current switching and zero-voltage switching technique, the stress of power switches can be reduce in chopping mode. When the commutation from one phase winding to another phase winding, the current can be zero as fast as possible in this period because several times negative voltage of DC-source voltage produce in phase winding. This paper is compared to performance based on conventional C-dump converter topology and the proposed resonant C-dump converter topology. Simulation and experimental results are presented to verify the effectiveness of the proposed circuit.

Quasi-Fixed-Frequency Hysteresis Current Tracking Control Strategy for Modular Multilevel Converters

  • Mei, Jun;Ji, Yu;Du, Xiaozhou;Ma, Tian;Huang, Can;Hu, Qinran
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1147-1156
    • /
    • 2014
  • This study proposes a quasi-fixed-frequency hysteresis current tracking control strategy for modular multilevel converters (MMCs) on the basis of voltage partition principle. First, by monitoring the grid voltage and the deviation between the output and reference currents, the output voltage is determined, thus prompting the output current to quickly and efficiently track the given current. Second, the voltages of the upper/lower capacitor of the arm and the voltages between the upper and lower arms are balanced by combining these arms with virtual loop mapping and arm voltage balance control, respectively. In particular, the proposed method is designed for any level and number of sub-modules. The validity of the proposed method is verified by simulations and experimental results of a five-level MMC prototype.

Sliding Mode Control with Fixed Switching Frequency for Four-wire Shunt Active Filter

  • Hamoudi, Farid;Chaghi, A. Aziz;Amimeur, Hocine;Merabet, El Kheir
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.647-657
    • /
    • 2011
  • The present paper proposes a sliding mode control with fixed switching frequency for three-phase three-leg voltage source inverter based four-wire shunt active power filter. The aim is to improve phase current waveform, neutral current mitigation, and reactive power compensation in electric power distribution system. The performed sliding mode for active filter current control is formulated using elementary differential geometry. The discrete control vector is deduced from the sliding surface accessibility using the Lyapunov stability. The problem of the switching frequency is addressed by considering hysteresis comparators for the switched signals generation. Through this method, a variable hysteresis band has been established as a function of the sliding mode equivalent control and a predefined switching frequency in order to keep this band constant. The proposed control has been verified with computer simulation which showed satisfactory results.

A Method for Adaptive Hysteresis Current Control of PWM Inverter Using Neural Network (신경회로망을 이용한 PWM 인버터의 적응 히스테리시스 전류제어 기법)

  • 전태원;최명규
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.382-387
    • /
    • 1998
  • The adaptive hysteresis band current control method using neural network is proposed to hold the switching frequency of PWM inverter constant at any operating points of ac motor. The adaptive hysteresis band equation is derived as the teaching signal of neural network. and then the structure and learning algorithm of the neural network a are suggested. The simulation results show that the switching frequency of PWM inverter is held constant at any operating conditions of ac motor and the proposed method has good transient performance of stator current.

  • PDF

Generalized Vector Control with Reactive Power Control for Brushless Doubly-Fed Induction Machines

  • Duan, Qiwei;Liu, Shi;Schlaberg, H. Inaki;Long, Teng
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.817-825
    • /
    • 2018
  • In this paper, a current hysteresis control with good decoupling properties for doubly-fed brushless induction machines (BDFIMs) has been proposed based on a generalized vector model. The independent control of the reactive power and speed for BDFIMs has been achieved by controlling the d-axis and the q-axis current of the control windings (CW). The proposed vector control method has been developed for the power winding (PW) flux frame. Experimental verification of a type Y180M-4 BDFIM prototype with 1/4 pole-pairs has been presented. Evidence of its good performance has been shown through experimental results.

SRM Driving Characteristics through Modeling of Variable Hysteresis Current Control (가변 히스테리시스 전류제어 모델링을 통한 SRM 구동특성)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.123-128
    • /
    • 2022
  • The torque of the SRM((Switched Reluctance Motor)) is proportional to the inductance slope, so it has a non-linear torque characteristic, and has a disadvantage in that the torque pulsation is large and noise is severe. In particular, the biggest obstacle to the commercialization of SRM is the pulsating torque generated from the rotating shaft, which has various adverse effects not only on the device itself but also on the peripheral devices. Therefore, various methods for reducing the pulsating torque have been published by domestic and foreign researchers, and there is a study result that the hysteresis controller has an advantage in that it can flow a smooth current compared to the chopping control. However, in determining the hysteresis band, if the band is too small, it has a disadvantage in that it may cause a switching loss due to many switching and an unstable initial start when the encoder is used. Therefore, in this paper, a variable hysteresis controller that can reduce torque ripple in a steady state while having a more stable and fast speed response through the change of the hysteresis band according to the speed error.

Power Closed-loop Control of Switched Reluctance Generator for High Efficiency Operation

  • Li, Zhenguo;Gao, Dongdong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.397-403
    • /
    • 2012
  • This paper describes a control method of turn-on/off angles to improve the efficiency of the switched reluctance generator(SRG) with a power closed-loop control system, and the inner-loop of the system is current hysteresis control. The SRG control system is constituted by the PI power controller and the two-level current hysteresis controller. By measuring and analyzing the system losses of different reference powers, speeds and turn-on/off angles, selection strategy of optimal turn-on/off angles is discussed. The proposed method is simple, reliable, and easy to achieve.

A study on the Novel Current Control method in vector controlled inverter drive system (벡터제어 인버터의 새로운 전류제어에 관한 연구)

  • Lee, Y.J.;Yim, N.H.;Oh, W.S.;Son, Y.D.;Min, K.K.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.346-350
    • /
    • 1990
  • This paper proposes a novel current control strategy for current regulated VSI-PWM transistor inverter. The conventional hysteresis control method has good dynamic responses. But the switching frequencies are high because it does not optimize switching patterns. Proposed current control strategy can optimize switching patterns. As regulator, three level comparators are used. The outputs of the comparators select appropriate inverter output voltage vectors via switching table stored in EPROM. The simulation and exparimental results in comparison to contentional hysteresis strategy are presented and discussed.

  • PDF

A Hysteresis & PI Current Controller Response Characteristic of SRM (스위치드 릴럭턴스 전동기의 히스테리시스 및 PI 전류제어기 응답특성)

  • Kim, Dong-Hee;Baik, Won-Sik;Kim, Min-Huei
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.25-31
    • /
    • 2007
  • This paper presents a comparison of different current controller response characteristics of SRM. The most common current controllers of the SRM is hysteresis type. The hysteresis controller is easy to implement and fast current control response, but has the inherent disadvantage of switching frequency variations. The other common type of current controller is PI scheme. The design of a classical PI current controller with fixed parameters for SRM is not an easy task due to the extreme nonlinear characteristics. In this paper, some linearization technique is used for design of PI current controller. Experimental results of 1-hp SRM are presented for the basic reference data which can be used to select the proper current control scheme according to the applications.

Control Method for Fault-Tolerant Active Power Filters

  • Zhang, Chenyu;Zheng, Jianyong;Mei, Jun;Deng, Kai;Zhou, Fuju
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.796-805
    • /
    • 2015
  • New direct and indirect current control methods for a fault-tolerant active power filter topology are presented in this paper. Since a three-phase four-switch topology has a phase bridge current which cannot be directly controlled, a hysteresis control method in the α-β plane which controls the three-phase current in the two-phase stationary coordinate system is proposed. The improved SVPWM algorithm is able to eliminate the operation of the trigonometric functions in the traditional algorithm by rotating the α-β coordinates and alternating the sequence of the output vectors, which in turn simplifies the algorithm and reduces the switching frequency. The selection of the DC-side reference voltage and DC-side capacitor equalization strategy are also discussed. Simulation and experiments demonstrate that the proposed control method is correct and feasible.