• Title/Summary/Keyword: HyperLab

Search Result 32, Processing Time 0.022 seconds

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.

Study on concrete surface damage using hyper-spectral remote sensing

  • Nakajima, Takashi;Endo, Takahiro;Yasuoka, Yoshifumi
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1055-1057
    • /
    • 2003
  • In this research, the concrete with paint film was classified using hyper-spectral remote sensing. First, spectral characteristics of concrete and concrete with some kinds of paint films were investigated with a spectrometer. Second, using reflectance and first order derivative, spectral characteristics of the normal concrete and the concrete with paint film were classified. By using hyper-spectral remote sensing, not only extraction of crack but also inspection of paint film distribution is possible.

  • PDF

Optimum SIL System Design with High NA and Large Tolerance

  • Won, Ki-Tak;Choi, Na-Rak;Kim, Jai-Soon;Lee, Ji-Yeon;Lee, Kyung-Eon;Shin, Yun-Sup
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.02a
    • /
    • pp.277-278
    • /
    • 2007
  • Even though high NA, Hyper SIL system easily decline the optical performance even a little alignment error. Not only to overcome this instability but to maintain the high NA gain, we suggest a new system (Optimum SIL) which is a combination of each advantage of Hyper SIL and Hemi SIL. Simulation results shows that Optimum SIL system has much higher tolerance to various performance-lowering factors than Hyper SIL system even with a relatively small NA resignation.

  • PDF

Management Software Development of Hyper Spectral Image Data for Deep Learning Training (딥러닝 학습을 위한 초분광 영상 데이터 관리 소프트웨어 개발)

  • Lee, Da-Been;Kim, Hong-Rak;Park, Jin-Ho;Hwang, Seon-Jeong;Shin, Jeong-Seop
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.111-116
    • /
    • 2021
  • The hyper-spectral image is data obtained by dividing the electromagnetic wave band in the infrared region into hundreds of wavelengths. It is used to find or classify objects in various fields. Recently, deep learning classification method has been attracting attention. In order to use hyper-spectral image data as deep learning training data, a processing technique is required compared to conventional visible light image data. To solve this problem, we developed a software that selects specific wavelength images from the hyper-spectral data cube and performs the ground truth task. We also developed software to manage data including environmental information. This paper describes the configuration and function of the software.

HyperCerts : Privacy-Enhanced OTP-Based Educational Certificate Blockchian System (HyperCerts : 개인정보를 고려한 OTP 기반 디지털 졸업장 블록체인 시스템)

  • Jung, Seung Wook
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.4
    • /
    • pp.987-997
    • /
    • 2018
  • Blockchain has tamper-free, so many applications are developing to leverage tamper-free features of blockchain. MIT Media Labs proposed BlockCerts, educational certificate blockchain System, to solve problems of legacy certificate verifications. Existing educational certificate blockchain Systems are based on public blockchain such as bitcoin, Ethereum, so any entity can participate educational institute in principal. Moreover, the exisitng educational certricate blockchain system utilizes the integrity of blockchain, but the confidentiality of the educational certificate is not provided. This paper propose a digital certificate system based on private blockchain, name HyperCerts. Therefore, only trusted entity can participate in the private blockchain network, Hyperledger, as the issuer of digital certificate. Furthermore, the practical byzantine fault tolerance is used as consensus algorithm, HyperCerts reduce dramatically the latency of issuing digital certificate and required computing power. HyperCerts stores the hash value of digital certificate into the ledger, so breach of personal information by malicious entity in the private blockchain is protected.

The effects of natural medicinal herb extracts on a lipoprotein lipase activity

  • Hwang, Jeong-Lyeor;Chung, Seung-Sik;Lee, Sung-Hyung;Choung, Se-Young
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.392.3-393
    • /
    • 2002
  • The increase of triglyceride in blood can be a signal of an increasing danger of arterial diseases when insulin resistance. diabetes. HDL -cholesterol decrease is accompanied. It is adjusted to triglyceride level in blood by a balance. which seems to be absorbed from VLDL metabolism in liver and by lipoprotein lipase activity. The hyper-triglyceride disease treatment proposal role should match with suppression does into liver or elimination of a triglyceride. (omitted)

  • PDF

Design & Implementation of Voice-Interface for Web-Browsing (웹 브라우징을 위한 음성 인터페이스 설계 및 구현)

  • Lee, Seung-Ho;Youk, Sang-Cho;Kwon, Young-Mi;Lee, Geuk
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 1998.04a
    • /
    • pp.106-109
    • /
    • 1998
  • WWW은 무한한 확장 가능성을 지닌 HTTP(Hyper-Text Transfer Protocol)와 편리한 웹 브라우져를 통해 질적, 양적 성장 계속해 왔으며 특히 GUI(Graphic User Interface) 환경에서 동작하는 웹 브라우져는 WWW이 수많은 이용자를 확보하는데 일익을 담당했다. 본 논문에서는 이 웹 브라우져에 음성인식 기술을 접목하여 WWW의 이용자가 자신의 음성으로 편리하게 웹 브라우징을 할 수 있도록 하는 음성 인터페이스를 설계, 구현 한다. 본 음성 인터페이스는 계속적으로 입력되는 음성 정보 중 화자의 발성음을 추출하여 음성 인식기에 전달하는 음성 입력기와 화자의 발성을 인식하는 음성 인식기 그리고 인식결과를 웹 브라우져에게 처리 하도록 하는 결과 처리기로 구성되어 있다.

  • PDF

Support Vector Machine and Spectral Angle Mapper Classifications of High Resolution Hyper Spectral Aerial Image

  • Enkhbaatar, Lkhagva;Jayakumar, S.;Heo, Joon
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.3
    • /
    • pp.233-242
    • /
    • 2009
  • This paper presents two different types of supervised classifiers such as support vector machine (SVM) and spectral angle mapper (SAM). The Compact Airborne Spectrographic Imager (CASI) high resolution aerial image was classified with the above two classifier. The image was classified into eight land use /land cover classes. Accuracy assessment and Kappa statistics were estimated for SVM and SAM separately. The overall classification accuracy and Kappa statistics value of the SAM were 69.0% and 0.62 respectively, which were higher than those of SVM (62.5%, 0.54).

Wide-Band Measurements of Antenna-Coupled Microbolometers for THz Imaging

  • Tamminen, Aleksi;Ala-Laurinaho, Juha;Mallat, Juha;Luukanen, Arttu;Grossman, Erich N.;Raisanen, Antti V.
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.132-137
    • /
    • 2010
  • We present results of room-temperature characterization of lithographically manufactured antenna-coupled NbN micro-bolometers. The bolometers are assembled together with a hyper-hemispherical Si lens to couple the incident radiation to the bolometer from the back-side of the substrate. The bolometers are designed to operate at 300~1,000 GHz and they are characterized at 321~782 GHz. Radiation patterns are measured at 321 GHz, 400 GHz, 654 GHz, and at 782 GHz. The frequency dependency of the beamwidth is studied with several azimuthal beam profile measurements at 321~500 GHz.