Radioopacity of Absorbable Plate containing Hydroxyapatite and Gold(Au); A Preliminary Report (Hydroxyapatite와 금(Au)이 혼합된 흡수성 고정판의 방사선비투과성; 예비 실험)

  • Kim, Yong Ha;Nam, Hyun Jae;Lee, Joon Ho;Kim, Kap Joong;Kim, Yeon Jung;Choi, Sik Young
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.419-422
    • /
    • 2008
  • Purpose: Absorbable bone fixation materials for operation of facial bone fracture are composed of poly- lactic acid(PLA) & poly-glycolic acid(PGA). These materials are absorbed after facial bone healing period. Therefore, these materials are harmless in human body. But because of it's radioopacity, the number and the location of the materials are not checked in follow-up X-ray examination. We studied absorbable bone fixation materials checked radiological examination. So, we made the absorbable plate composed of PLA, Hydroxyapatite (HA) and Gold(Au). Methods: Plate 1 was consisted of pure PLA. Plate 2 was consisted of PLA(50%) and HA(50%). Plate 3 - 7 were consisted of PLA(50%), and variable composition of HA & Au. The ratio of Au was as following. From the plate 3 to plate 7, the Au ratio was 1%, 5%, 10%, 17%, and 25%, respectively. Total 3 examinations were used-naked eye examination, simple X-ray examination, and Haunsfield unit of plate in CT examination. Results: Naked eye examination found out that the color of plate 1 was most white. As the Au ratio increases, the color of plate was getting close to khaki color. the radioopacity of plate 2 was similar cortical bone of face in simple X-ray. The Haunsfield unit of cortical bone of face was 1000 HU. Haunsfield unit of titanium plate was 2900 HU. Haunsfield unit of plate 1 through plate 7 were -242, 1489, 1776, 3052, 3092, 3095, and 3095, respectively. Conclusion: Radioopacity of plate 2 was similar to cortical bone of face. In CT examination, Hanusfield unit of plate 2 was similar to Hanusfield unit of cortical bone of face. Hanusfield unit of plate 4 - 7 were similar to Hanusfield unit of titanium plate. So to trace bone fixation materials after facial bone surgery, the best ratio of Au is about 1 - 5%. If this study is applied to facial bone surgery, radiologic follow up would be easy after facial bone surgery.

Fabrication and characterization of porous hydroxyapatite scaffolds with PMMA addition using tertiary-butyl alcohol based freeze casting method (삼차부틸알코올 기반 동결주조 공정을 이용한 PMMA 첨가 다공질 수산화아파타이트 지지체의 제조 및 특성 평가)

  • Kim, Tae-Rim;Yoon, Seog-Young;Heo, Jin-Young;Lee, Chi-Seung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.5
    • /
    • pp.235-242
    • /
    • 2017
  • In order to prepare porous scaffolds capable of pore control, PMMA powder serving as a pore-forming agent was added to HA powder to synthesize a slurry containing TBA as a solvent. And then, porous HA scaffolds where pillarshaped pore channels interconnected with each other were fabricated by freeze-casting and sintering. The crystal structure of the HA scaffolds according to the addition amount of PMMA powder was measured by XRD and the surface and inner cross section of the scaffolds were analyzed through SEM. It was found that removal of PMMA during sintering affects the internal structure of the scaffolds and the crystallinity of the HA powder. Furthermore, through evaluating the physical and mechanical properties of the scaffolds, it was confirmed that the porosity, pore size and compressive strength can be controlled by controlling the addition amount of the pore-forming agent. It was also found that the HA scaffolds produced in this study were similar in structure and properties to the natural cancellous bone. This suggests that porous HA scaffolds with PMMA can be used as an alternative to autogenous bone for tissue engineering as an artificial bone scaffold.

The Growth of Osteoblasts according to the Pretreatment of HA Scaffold Surface (하이드록시아파타이트 지지체의 표면 처리 방법에 따른 골아세포의 성장)

  • Park, Byung-Chan;Kim, Yong-Ha;Kim, Tae-Gon;LeeYoun-Jung, Jun-Ho;Sik-Young, Kim;Choi, Sik-Young
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.340-345
    • /
    • 2010
  • Purpose: Recently, bioceramics have become popular as a substitute graft material for reconstruction of bony defect after trauma or tumor surgery. Among the bioceramic materials, hydroxyapatite (HA) is favored due to its biocompatibility. HA scaffold is composed of the interconnected reticular framework, macropores and micropores. Macropores play an important role in cell migration, nutrients supply and vascular ingrowth. On the other hand, a number of micropores less than $10{\mu}m$ form an irregular surface on HA scaffolds, which prevents the osteoblast from adhering and proliferating on the surface of HA scaffold. Methods: In this study, three different groups were designed for comparison. In the first group (group A), conventional method was used, in which HA pellet was applied without surface pretreatment. The second group (group B) was given a HA pellet that has been coated with crystalline HA solution prior to application. In the third group (group C), the same method was used as the second group, where the pretreated HA pellet was heated ($1250^{\circ}C$, 1 hour) before application. Osteoblast-like cells ($2{\times}10^4$/mL) were scattered onto every pellet, then they were incubated in 5% $CO_2$ incubator at $37^{\circ}C$ for twelve days. During the first three days, osteoblast cells were counted using the hemocytometer daily. ALP activity was measured on the 3, 6, 9 and 12 culture days using the spectrophotometer. Results: Under SEM, group A showed a surface with numerous micropores, and group B revealed more rough crystal surface. Group C revealed a fused crystal appearance and flattened smooth surface. In proliferation and ALP activity of osteoblast cells, group C showed better results compared to group B. Group A which lacks pretreatment of the surface showed less osteoblast proliferation and ALP activity than group C, but showed better results than group B. Conclusion: We found that crystallized HA with heat treatment method enhances the osteoblasts proliferation and differentiation on the surface of HA pellets.

Convergence study of mechanical properties and biocompatability of Ti Gr4 surface coated with HA using plasma spray for ossoeintegration (골융합 촉진을 위한 Ti Gr4의 HA 코팅에 대한 물리적 특성과 생체안정성에 대한 융합적 연구)

  • Hwang, Gab-Woon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.145-151
    • /
    • 2021
  • This study aimed to investigate the efficient conduct of HA coating on Ti Gr4 for the practical use of medical device. Ti Gr4 alloy specimens measuring 𝜱 25mm × 1mm were sprayed with hydroxyapatite using thermal spray according to ASTM F1185-88. The surface was evaluated at #120, #400, #1,000 sandpaper and barrel finishing. Each coating properties was analyzed using SEM, UTS 20,000psi cap. and in vitro cytotoxicity. Surface morphology consists of well molten particles with very little resolidified or unmolten areas. The average Ca/P ratio is 1.74 which is in good agreement with theoretical value of 1.67. The average roughness Ra is very representative of roughness of specimen. The coatings are dense and well adhered to the substrate. The average bond strength was 61.74 MPa with a standard deviation of 4.06 which indicates fairly reliable results for ASTM 633 type tests. Variations in results from jig design, epoxy used, crosshead speeds etc. in vitro cytotoxicity result had a Grade 3. The results of the study are expected to be helpful in osseointegration and plasma-spray HA coated Ti Gr4 are more satisfactory in HA coating thickness elevation which is preferable to any other system.

Effects of different sizes of Hydroxyapatite/$\beta$-Tricalcium phosphate particles on vertical bone augmentation (수직골 증대술에서 $\beta$-Tricalciumphosphate/Hydroxyapatite 골 이식재 입자 크기의 영향)

  • Huh, Jung-Bo;Jung, Dong-Hee;Kim, Ji-Sun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.259-265
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of different sizes of $\beta$-TCP/ HA particles on vertical bone augmentation using titanium mesh in the cranium of rabbits. Materials and methods: Six white rabbits weighing 5kg were used. Four circular grooves of 6mm diameter were made by trephine, and five small holes were drilled in the inner surface of each circular gooves. Different sizes of grafts (small 0.3 - 0.5 mm, medium 0.5 - 1.0, large 1.0 - 2.0 mm) were placed respectively in the experimental groups. Titanium mesh (height 3 mm, width 6 mm) was placed. After 8weeks healing period, the rabbits were euthanized, and the specimens were prepared for histological findings. New bone formation and remaining graft area were measured to calculate the ratio of areas occupying the inner space of titanium mesh. Mann-Whitney U-test and Wilcoxon signed rank-test were used for statistical analysis ($\alpha$ = .05). Results: The experimental groups with $\beta$-TCP/HA graft showed a significantly higher new bone formation (P = .003). Comparing different sizes of $\beta$-TCP/HA, there was no statistical difference in terms of new bone formation. The vertical bone formation (i.e. new bone and graft area) was significantly greater in $\beta$-TCP/HA groups (P = .001). In comparison between different sizes of $\beta$-TCP/HA, medium size group had significantly greater area than large particle size group (P = .039). Conclusion: The use of $\beta$-TCP/HA with titanium mesh showed a higher vertical bone formation, particularly the medium sized $\beta$-TCP/HA particles (0.5 - 1.0 mm) produced better results in vertical bone augmentation.

Zn/HA Coating on the Ti-xNb Alloys after Nanotube Formation for Dental Implant

  • Byeon, In-Seop;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.139-140
    • /
    • 2015
  • Zn/HA coating on the Ti-xNb alloys after nanotube formation for dental lmplant was researched using various experimental methods. Due to g ood biocompatibility and osteoconductivity, hydroxyapatite (HA) coating s on metallic biomedical implants were widely employed in orthopedic and dental applications. To improve biocompatibilities, Zinc (Zn) plays very important roles in the bone formation and immune reg ulations. The nanotube formed Zn-HA films were characterized with X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS).

  • PDF

EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS (Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가)

  • Park, Jee-Hyun;Hwang, Sun-Jung;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT (임플랜트 표면처리가 생체활성에 미치는 영향)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Yoon, Tae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.

Surface characteristics of a novel hydroxyapatite-coated dental implant

  • Jung, Ui-Won;Hwang, Ji-Wan;Choi, Da-Yae;Hu, Kyung-Seok;Kwon, Mi-Kyung;Choi, Seong-Ho;Kim, Hee-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.59-63
    • /
    • 2012
  • Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe's test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total, seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer's instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.

Dentinal Tubules Occluding Effect Using Nonthermal Atmospheric Plasma

  • Lee, Chang Han;Kim, Young Min;Kim, Gyoo Cheon;Kim, Shin
    • International Journal of Oral Biology
    • /
    • v.43 no.2
    • /
    • pp.83-91
    • /
    • 2018
  • Nonthermal atmospheric plasma has been studied for its many biomedical effects, such as tooth bleaching, wound healing, and coagulation. In this study, the effects of dentinal tubules occlusion were investigated using fluoride-carboxymethyl cellulose (F-CMC) gel, nano-sized hydroxyapatite (n-HA), and nonthermal atmospheric plasma. Human dentin specimens were divided to 5 groups (group C, HA, HAF, HAP, and HAFP). Group HA was treated with n-HA, group HAF was treated with n-HA after a F-CMC gel application, group HAP was treated with n-HA after a plasma treatment and group HAFP was treated with n-HA after a plasma and F-CMC gel treatment. The occlusion of dentinal tubules was investigated using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), which shows Ca/P ratio. In the EDS results, a higher Ca/P ratio was shown in the groups including n-HA than in the control group. The specimens of group HAP and HAFP had a higher Ca/P ratio in retentivity. In the SEM results, there was not a significant difference in the amount of times applied. Therefore, this study suggests F-CMC gel and n-HA treatment using nonthermal atmospheric plasma will be a new treatment method for decreasing hypersensitivity.