DOI QR코드

DOI QR Code

Surface characteristics of a novel hydroxyapatite-coated dental implant

  • Jung, Ui-Won (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry) ;
  • Hwang, Ji-Wan (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry) ;
  • Choi, Da-Yae (Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Center, Yonsei University College of Dentistry) ;
  • Hu, Kyung-Seok (Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Center, Yonsei University College of Dentistry) ;
  • Kwon, Mi-Kyung (Research Institute of Dentis Co.) ;
  • Choi, Seong-Ho (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry) ;
  • Kim, Hee-Jin (Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Center, Yonsei University College of Dentistry)
  • Received : 2012.02.10
  • Accepted : 2012.03.20
  • Published : 2012.04.30

Abstract

Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe's test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total, seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer's instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.

Keywords

References

  1. Chaffee NR, Cooper LF. Fixed partial dentures combining both resin-bonded and conventional retainers: a clinical report. J Prosthet Dent 2000;83:272-5. https://doi.org/10.1016/S0022-3913(00)70126-0
  2. Shalabi MM, Gortemaker A, Van't Hof MA, Jansen JA, Creugers NH. Implant surface roughness and bone healing: a systematic review. J Dent Res 2006;85:496-500. https://doi.org/10.1177/154405910608500603
  3. Wennerberg A, Albrektsson T. Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res 2009;20 Suppl 4:172-84. https://doi.org/10.1111/j.1600-0501.2009.01775.x
  4. Wennerberg A, Albrektsson T. On implant surfaces: a review of current knowledge and opinions. Int J Oral Maxillofac Implants 2010;25:63-74.
  5. de Groot K, Geesink R, Klein CP, Serekian P. Plasma sprayed coatings of hydroxylapatite. J Biomed Mater Res 1987;21:1375-81. https://doi.org/10.1002/jbm.820211203
  6. Thomas KA, Kay JF, Cook SD, Jarcho M. The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials. J Biomed Mater Res 1987;21:1395-414. https://doi.org/10.1002/jbm.820211205
  7. Wang CY, Zhao BH, Ai HJ, Wang YW. Comparison of biological characteristics of mesenchymal stem cells grown on two different titanium implant surfaces. Biomed Mater 2008;3:015004. https://doi.org/10.1088/1748-6041/3/1/015004
  8. Park YS, Yi KY, Lee IS, Han CH, Jung YC. The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae. Int J Oral Maxillofac Implants 2005;20:31-8.
  9. Gottlander M, Albrektsson T. Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Implants 1991;6:399-404.
  10. Ji H, Marquis PM. Effect of heat treatment on the microstructure of plasma-sprayed hydroxyapatite coating. Biomaterials 1993;14:64-8. https://doi.org/10.1016/0142-9612(93)90077-F
  11. Zyman Z, Weng J, Liu X, Zhang X, Ma Z. Amorphous phase and morphological structure of hydroxyapatite plasma coatings. Biomaterials 1993;14:225-8. https://doi.org/10.1016/0142-9612(93)90027-Y
  12. Chen J, Wolke JG, de Groot K. Microstructure and crystallinity in hydroxyapatite coatings. Biomaterials 1994;15:396-9. https://doi.org/10.1016/0142-9612(94)90253-4
  13. Tsui YC, Doyle C, Clyne TW. Plasma sprayed hydroxyapatite coatings on titanium substrates. Part 2: optimisation of coating properties. Biomaterials 1998;19:2031-43. https://doi.org/10.1016/S0142-9612(98)00104-5
  14. Biesbrock AR, Edgerton M. Evaluation of the clinical predictability of hydroxyapatite-coated endosseous dental implants: a review of the literature. Int J Oral Maxillofac Implants 1995;10:712-20.
  15. Liao H, Fartash B, Li J. Stability of hydroxyapatite-coatings on titanium oral implants (IMZ). 2 retrieved cases. Clin Oral Implants Res 1997;8:68-72. https://doi.org/10.1111/j.1600-0501.1997.tb00009.x
  16. Ong JL, Lucas LC, Lacefield WR, Rigney ED. Structure, solubility and bond strength of thin calcium phosphate coatings produced by ion beam sputter deposition. Biomaterials 1992;13:249-54. https://doi.org/10.1016/0142-9612(92)90192-Q
  17. Yoshinari M, Ohtsuka Y, Derand T. Thin hydroxyapatite coating produced by the ion beam dynamic mixing method. Biomaterials 1994;15:529-35. https://doi.org/10.1016/0142-9612(94)90019-1
  18. van Dijk K, Schaeken HG, Wolke JG, Jansen JA. Influence of annealing temperature on RF magnetron sputtered calcium phosphate coatings. Biomaterials 1996;17:405-10. https://doi.org/10.1016/0142-9612(96)89656-6
  19. Singh RK, Qian F, Nagabushnam V, Damodaran R, Moudgil BM. Excimer laser deposition of hydroxyapatite thin films. Biomaterials 1994;15:522-8. https://doi.org/10.1016/0142-9612(94)90018-3
  20. Albrektsson T, Wennerberg A. Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. Int J Prosthodont 2004;17:536-43.
  21. Yang Y, Bumgardner JD, Cavin R, Carnes DL, Ong JL. Osteoblast precursor cell attachment on heat-treated calcium phosphate coatings. J Dent Res 2003;82:449-53. https://doi.org/10.1177/154405910308200609
  22. Katto M, Ishibashi K, Kurosawa K, Yokotani A, Kubodera S, Kameyama A, et al. Crystallized hydroxyapatite coatings deposited by PLD with targets of different densities. J Phys: Conf Ser 2007;59:75-8. https://doi.org/10.1088/1742-6596/59/1/016
  23. Cleries L, Fernandez-Pradas JM, Sardin G, Morenza JL. Dissolution behaviour of calcium phosphate coatings obtained by laser ablation. Biomaterials 1998;19:1483-7. https://doi.org/10.1016/S0142-9612(98)00063-5
  24. Arias JL, Garcia-Sanz FJ, Mayor MB, Chiussi S, Pou J, Leon B, et al. Physicochemical properties of calcium phosphate coatings produced by pulsed laser deposition at different water vapour pressures. Biomaterials 1998;19:883-8. https://doi.org/10.1016/S0142-9612(97)00168-3
  25. Rupp F, Scheideler L, Olshanska N, de Wild M, Wieland M, Geis-Gerstorfer J. Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces. J Biomed Mater Res A 2006; 76:323-34.
  26. Buser D, Broggini N, Wieland M, Schenk RK, Denzer AJ, Cochran DL, et al. Enhanced bone apposition to a chemically modified SLA titanium surface. J Dent Res 2004;83: 529-33. https://doi.org/10.1177/154405910408300704
  27. Ferguson SJ, Broggini N, Wieland M, de Wild M, Rupp F, Geis-Gerstorfer J, et al. Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acid-etched titanium surface. J Biomed Mater Res A 2006;78: 291-7.

Cited by

  1. Bone apposition on implants coated with calcium phosphate by ion beam assisted deposition in oversized drilled sockets: a histologic and histometric analysis in dogs vol.43, pp.1, 2012, https://doi.org/10.5051/jpis.2013.43.1.18
  2. Calcium orthophosphates in dentistry vol.24, pp.6, 2012, https://doi.org/10.1007/s10856-013-4898-1
  3. Reosseointegration of mechanically disintegrated implants in dogs: mechanical and histometric analyses vol.25, pp.6, 2012, https://doi.org/10.1111/clr.12135
  4. Secondary stability of microthickness hydroxyapatite‐coated dental implants installed without primary stability in dogs vol.25, pp.10, 2014, https://doi.org/10.1111/clr.12226
  5. Coating of titanium implants with boron nitride by RF-magnetron sputtering vol.39, pp.5, 2012, https://doi.org/10.1007/s12034-016-1273-0
  6. A hybrid electrospinning and electrospraying 3D printing for tissue engineered scaffolds vol.23, pp.6, 2012, https://doi.org/10.1108/rpj-08-2015-0111
  7. Comparative study for osseointegration according to surface treatments of dental implants vol.44, pp.2, 2012, https://doi.org/10.21851/obr.44.02.202006.77
  8. Development of a Surface-Functionalized Titanium Implant for Promoting Osseointegration: Surface Characteristics, Hemocompatibility, and In Vivo Evaluation vol.10, pp.23, 2020, https://doi.org/10.3390/app10238582
  9. Current Challenges and Innovative Developments in Hydroxyapatite-Based Coatings on Metallic Materials for Bone Implantation: A Review vol.10, pp.12, 2012, https://doi.org/10.3390/coatings10121249
  10. Hydroxyapatite Synthesis and Covering of Titanium Surfaces by Dip-Coating Method vol.64, pp.None, 2012, https://doi.org/10.1590/1678-4324-2021200344
  11. Drug-Releasing Antibacterial Coating Made from Nano-Hydroxyapatite Using the Sonocoating Method vol.11, pp.7, 2012, https://doi.org/10.3390/nano11071690
  12. Effects of Long Durations of RF-Magnetron Sputtering Deposition of Hydroxyapatite on Titanium Dental Implants vol.15, pp.3, 2012, https://doi.org/10.1055/s-0040-1721314
  13. Highly Segregated Biocomposite Membrane as a Functionally Graded Template for Periodontal Tissue Regeneration vol.11, pp.9, 2012, https://doi.org/10.3390/membranes11090667
  14. Formation of the octadecylphosphonic acid layer on the surface of Ti6Al4V ELI titanium alloy and analysis using Raman spectroscopy vol.265, pp.None, 2022, https://doi.org/10.1016/j.saa.2021.120368