• 제목/요약/키워드: Hydrogen ion concentration

검색결과 235건 처리시간 0.025초

Benzaldehyde와 Semicarbazide의 결합에 미치는 pH치의 영향 (The Effect of pH on the Condensation Reaction of Benzaldehyde and Semicarbazide)

  • 이길상;김인자
    • 약학회지
    • /
    • 제6권1호
    • /
    • pp.5-7
    • /
    • 1962
  • Like the condensation reaction of general aldehyde, that of benzaldehyde with semicarbazide also depends upon the concentration of carbonium ion that is produced by hydrogen ion. The lower pH value is the facility of the formation of carbonium ion in the condensation reaction, while the reactivity of semicarbazide as a reactant is reduced. In this paper, therefore we want to find out the optimum pH value in the condensation reaction of benzaldehyde with semicarbazide. This optimum pH value was determined by using the simple paper-chromatographic method. According to the result of this experiment, the condensation reaction between benzaldehyde and semicarbazide reacts with its highest point at 3.5pH value. It seems clear that at this point the benzaldehyde acquires the most suitable amount of carbonium ion for the condensation reaction with semicarbazide, and the semicarbazide also has the optimum reactivity.

  • PDF

리튬이온 배터리의 열폭주 이상징후 감지를 위한 측정 변수 특성 분석 (Characteristics Analysis of Measurement Variables for Detecting Anomaly Signs of Thermal Runaway in Lithium-Ion Batteries)

  • 임병주;조성훈;이가람;최석민;박창대
    • 한국수소및신에너지학회논문집
    • /
    • 제33권1호
    • /
    • pp.85-94
    • /
    • 2022
  • To detect anomaly signs of thermal runaway in advance, this study analyzed the signals from various sensors installed in lithium-ion batteries. The thermal runaway mechanism was analyzed, and measurement variables for anomalies of a battery cell were surface temperature, strain, and gas concentration. The changes and characteristics of three variables during the thermal runaway process were analyzed under the abuse environment: the overheat and the overcharge. In experiment, the thermal runaway of the battery proceeded in the initial developing stage, the outgassing stage, and the ignition stage. Analysis from the measured data indicated that the suitable variable to detect all stages of thermal runaway is the surface temperature of the battery, and surface strain is alternative.

Source identification and Pathway analysis of Nitrate contamintation in "Cultural village", Jeungpyeong

  • 전성천;이강근;배광옥;정형재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.254-257
    • /
    • 2002
  • The purposes of this research are to identify the source and to analyze the pathway of nitrate contamination in "cultural village", Jeungpyeong. In order to examine recharge processes and flow pattern that closely related to the influent of nitrate contaminant, the flow field was simulated and the oxygen and hydrogen stable isotopes were analyzed. The nitrogen isotope was used to delineate contaminant sources. The shallow groundwater was mainly composed of precipitation, but leakage of domestic water and sewage contributed to the recharge. Nitrate contaminants were possibly from the leakage of sewage and animal waste. The nitrate concentration decreased due to dilution by low concentration water.ion water.

  • PDF

불포화 자연토의 동전기 시스템에 따른 정화 특성 (The Remediation Characteristics of Natural Soil according to ElectroKinetic Remediation Systems under Unsaturated Conditions)

  • 김병일;김기년;한상재;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.873-881
    • /
    • 2004
  • A serious of EK remediation tests on contaminated soil are performed under unsaturated conditions and analyzed for electrical potential, water content, pH and so on. The results indicated that electrical potential and pH distributions in the sample are dependent on the amount and inward/outward flow of hydrogen ion. Specially, for the closed system the water content is largely decreased with the flow of hydrogen. The maximum electrical conductivity is measured at the catholyte of CEM(Sealing) test and directly related to the remedial efficiency. Although pHs in the region near to the anode are similarly developed, the different concentration of lead is measured with the electrical gradient contrary to the lead concentration dependent on pH within the sample.

  • PDF

Effect of $H_2S$ Partial Pressure and pH of Test Solution on Hydrogen Induced Cracking of High Strength Low Alloy Steels

  • Kim, Wan Keun;Koh, Seong Ung;Kim, Kyoo Young;Yang, Boo Young;Jung, Hwan Kyo
    • Corrosion Science and Technology
    • /
    • 제4권6호
    • /
    • pp.236-241
    • /
    • 2005
  • Hydrogen induced cracking (HIC) is one of the hydrogen degradation phenomena of linepipe steels caused by $H_2S$ gas in the crude oil or natural gas. However, NACE TM0284-96 standard HIC test method is hard to satisfy the steel requirements for sour service application since it uses more severe environmental conditions than actual conditions. Therefore, in order to use steels effectively, it is required to evaluate HIC resistance of steels in the practical range of environmental severity. In this study, HIC resistance of two high strength low alloy (HSLA) steels being used as line pipe steels was evaluated in various test solutions with different $H_2S$ pressures and pH values. The results showed that the key parameter affecting crack area ratio (CAR) is $H_2S$ partial pressure of test solution when the pH value of test solution is not over 4. Hydrogen diffusivity was not a constant value, but it was rather affected by the hydrogen ion concentration (pH value) in the solution.

황산 산성용액에서 기체발생에 의한 $N_2H_4-I_2$ 반응속도 (Gas Evolution Kinetics of $N_2H_4-I_2$ Reaction in a Sulfuric Acid Medium)

  • 최주현
    • 대한화학회지
    • /
    • 제18권3호
    • /
    • pp.153-156
    • /
    • 1974
  • 황산산성에서의 히드라진과 요오드의 반응에 대하여, 기체발생속도를 측정하였다. 이미 보고된 요오등의 소비속도의 경우와 마찬가지로, 히드라진 및 요오드의 농도에 관하여는 1차 반응이며, 반응속도는 요오드화이온의 농도에 역비례한다. 그뿐만 아니라, 요오드으이 소비속도롸 기체 발생속도가 거의 같으므로, 수명이 긴 중간물이 생기지 않는다고 결론지을 수 있다

  • PDF

Mass Transfer to Amalgamated Copper Rotating Disk Electrode

  • Sulaymon, Abbas H.;Abbar, Ali H.
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권4호
    • /
    • pp.165-171
    • /
    • 2012
  • An experimental study of mass transfer to an amalgamated copper rotating disc electrode has been employed to determine an empirical correlation for the mass transfer rate in laminar flow. The study was performed in a three-electrodes configuration using 0.1 M boric acid and 0.1M potassium chloride as supporting electrolyte with Zn (II) concentration in the range (25-100 mg $dm^{-3}$). Polarization curves at different zinc ion concentration are reported. Hydrogen and oxygen reduction has also been considered.The diffusion coefficients and mass transfer coefficient were obtained using limiting diffusion current technique based on zinc ion reduction. A least squares analysis indicates that the laminar flow results for 13067 < Re > 57552 and 550 < Sc > 1390 can be correlated by the following equation with correlation coefficient (CR) equal to 0.98: $sh=0.61Re^{0.5}Sc^{1/3}$.

전기-펜톤 반응을 이용한 해수 중의 염료 분해 (Dye Decomposition in Seawater using Electro-Fenton Reaction)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제29권4호
    • /
    • pp.383-393
    • /
    • 2020
  • To increase electrolysis performance, the applicability of seawater to the iron-fed electro-Fenton process was considered. Three kinds of graphite electrodes (activated carbon fiber-ACF, carbon felt, graphite) and dimensionally stable anode (DSA) electrode were used to select a cathode having excellent hydrogen peroxide generation and organic decomposition ability. The concentration of hydrogen peroxide produced by ACF was 11.2 mg/L and those of DSA, graphite, and carbon felt cathodes were 12.9 ~ 13.9 mg/L. In consideration of durability, the DSA electrode was selected as the cathode. The optimum current density was found to be 0.11 A/㎠, the optimal Fe2+ dose was 10 mg/L, and the optimal ratio of Fe2+ dose and hydrogen peroxide was determined to be 1:1. The optimum air supply for hydrogen peroxide production and Rhodamine B (RhB) degradation was determined to be 1 L/min. The electro-Fenton process of adding iron salt to the electrolysis reaction may be shown to be more advantageous for RhB degradation than when using iron electrode to produce hydrogen peroxide and iron ion, or electro-Fenton reaction with DSA electrode after generating iron ions using an iron electrode.

Alignment property change in DLC alignment layer containing various hydrogen concentration

  • Kim, Jong-Bok;Kim, Kyung-Chan;Ahn, Han-Jin;Hwang, Byung-Har;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.378-380
    • /
    • 2005
  • Diamond like carbon (DLC) films are known that they show homogeneous alignment property when they are irradiated by Ar ion beam. The DLC films in most of studies were deposited by CVD and contain large mount of hydrogen. In order to identity the hydrogen effect on alignment property, DLC films is deposited by RF magnetron sputter using various ratio of Ar and H2 as reactive gas. DLC films are characterized by FT-IR, Raman and contact angle. Alignment property is estimated by measuring pretilt angle.

  • PDF

과산화수소를 혼합한 염산용액으로 폐리튬이온배터리의 용융환원된 금속합금의 침출 (Leaching of Smelting Reduced Metallic Alloy of Spent Lithium Ion Batteries by the Mixture of Hydrochloric Acid and H2O2)

  • 문현승;;이만승
    • 자원리싸이클링
    • /
    • 제30권5호
    • /
    • pp.25-31
    • /
    • 2021
  • 폐리튬이온배터리를 고온에서 용융환원처리하면 코발트, 니켈 및 구리가 환원된 금속을 얻을 수 있다. 본 논문에서는 상기 금속외에 망간, 철 및 규소가 같이 환원된 금속합금의 침출을 조사하였다. 침출용액으로 염산에 과산화수소를 산화제로 첨가해 염산과 산화제의 농도, 반응시간 및 온도와 광액밀도를 변화시켜 니켈, 코발트 및 구리를 99% 이상 침출시킬 수 있는 조건을 조사하였다. 과산화수소 농도와 광액밀도가 금속의 침출에 미치는 영향이 현저했으며 20에서 80℃의 반응온도범위에서 반응온도는 침출에 큰 영향을 미치지 않았다. 2M의 염산용액에서 5%의 과산화수소를 혼합한 용액으로 60℃의 반응온도와 30 g/L의 광액밀도조건에서 150분 반응시키면 규소를 제외한 모든 금속이 99% 이상 침출되었다.